Comparison of trabecular bone behavior in core and whole bone samples using high-resolution modeling of a vertebral body

被引:0
|
作者
Noel M. Harrison
Peter E. McHugh
机构
[1] National University of Ireland,National Centre for Biomedical Engineering Science
[2] National University of Ireland,Department of Mechanical and Biomedical Engineering
关键词
Trabecular; Cancellous; Voxel; Vertebra; Basivertebral; Finite element;
D O I
暂无
中图分类号
学科分类号
摘要
Computational analysis of trabecular bone normally involves the modeling of (experimental tests of) cored samples. However, the lack of constraint on the sides of the extracted trabecular bone samples limits the information that can be inferred regarding true in situ behavior. Here, the element-by-element voxel-based finite element method was applied via, a custom-written software suite (FEEBE), to a 72 μm resolution model of an ovine vertebra. The difference between the apparent modulus of eight concentric core cylinders when modeled as part of the whole bone (containing 84 × 106 degrees of freedom) and independent of the whole bone was investigated. The results showed that cored trabecular bone apparent modulus depended significantly on the core diameter when modeled as an extracted core (r2 = 0.975) and as part of a whole bone (r2 = 0.986). The cause of this result was separated into the side-artifact effect and bone volume fraction (BV/TV) effect. For the independently modeled cores, the apparent modulus of an inner core region of interest varied with increasing thickness of the outer annulus. This was attributed to the side-artifact effect, given that the BV/TV of the core region was constant. Within the whole trabecular structure, the side artifact was eliminated as the entire bone structure was modeled. However, a BV/TV effect influenced the apparent modulus depending on the size of the core selected for determining apparent modulus. Changing the size of the core varied the overall BV/TV of the core, and this significantly (r2 = 0.999) influences the apparent modulus. Therefore, determining a ‘true’ apparent modulus for trabecular bone was not achievable. The independently modeled cores consistently under-predict the in vivo apparent modulus. It is recommended that if a ‘true’ apparent modulus is required, the BV/TV at which it is required needs to be first determined. Apparent modeling of entire bones at microscale resolution allowed regions of low and high tissue strains to be identified, consistent with patterns of trabecular bone remodeling and resorption reported in literature. The basivertebral vein cavity underwent the highest strains within the entire vertebral body, suggesting that failure might initiate here, despite containing visibly thicker struts and plate trabeculae. Although computationally expensive, analysis of the entire vertebral body provided a full picture of in situ trabecular bone deformation.
引用
收藏
页码:469 / 480
页数:11
相关论文
共 50 条
  • [31] Acromegaly Has a Negative Influence on Trabecular Bone, But Not on Cortical Bone, as Assessed by High-Resolution Peripheral Quantitative Computed Tomography
    Madeira, Miguel
    Neto, Leonardo Vieira
    Paranhos Neto, Francisco de Paula
    Barbosa Lima, Inaya Correa
    Carvalho de Mendonca, Laura Maria
    Gadelha, Monica Roberto
    Fleiuss de Farias, Maria Lucia
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 98 (04): : 1734 - 1741
  • [32] Underdeveloped trabecular bone microarchitecture is detected in children with cerebral palsy using high-resolution magnetic resonance imaging
    C. M. Modlesky
    P. Subramanian
    F. Miller
    Osteoporosis International, 2008, 19 : 169 - 176
  • [33] Underdeveloped trabecular bone microarchitecture is detected in children with cerebral palsy using high-resolution magnetic resonance imaging
    Modlesky, C. M.
    Subramanian, P.
    Miller, F.
    OSTEOPOROSIS INTERNATIONAL, 2008, 19 (02) : 169 - 176
  • [34] Assessment of trabecular and cortical parameters using high-resolution peripheral quantitative computed tomography, histomorphometry and microCT of iliac crest bone core in hemodialysis patients
    Pichone, Alinie
    Gomes, Carlos Perez
    Cardoso Lima, Luis Felipe
    Moreira, Carolina Aguiar
    Paranhos-Neto, Francisco de Paula
    Madeira, Miguel
    Lopes, Ricardo Tadeu
    Fleiuss Farias, Maria Lucia
    Leite Jr, Maurilo
    BONE REPORTS, 2022, 16
  • [35] Local 3D scaling properties for the analysis of trabecular bone extracted from high-resolution magnetic resonance imaging of human trabecular bone - Comparison with bone mineral density in the prediction of biomechanical strength in vitro
    Boehm, HF
    Raeth, C
    Monetti, RA
    Mueller, D
    Newitt, D
    Majumdar, S
    Rummeny, E
    Morfill, G
    Link, TM
    INVESTIGATIVE RADIOLOGY, 2003, 38 (05) : 269 - 280
  • [37] Assessing bone impairment in ankylosing spondylitis (AS) using the trabecular bone score (TBS) and high-resolution peripheral quantitative computed tomography (HR-pQCT)
    Caparbo, Valeria F.
    Furlam, Pedro
    Saad, Carla G. S.
    Alvarenga, Jackeline C.
    Aubry-Rozier, Berengere
    Hans, Didier
    de Brum-Fernandes, Artur J.
    Pereira, Rosa M. R.
    BONE, 2019, 122 : 8 - 13
  • [38] An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue
    Baruffaldi, F.
    Beituzzi, M.
    Bianconi, D.
    Brancaccio, R.
    Cornacchia, S.
    Lanconelli, N.
    Mancini, L.
    Morigi, M. P.
    Pasini, A.
    Perilli, E.
    Romani, D.
    Rossi, A.
    Casali, E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2584 - 2590
  • [39] Measuring changes of 3D structures in high-resolution μCT images of trabecular bone
    Marwan, Norbert
    Kurths, Juergen
    Saparin, Peter
    Thomsen, Jesper S.
    BIOSIGNALS 2008: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING, VOL II, 2008, : 425 - 430
  • [40] High-resolution magnetic resonance imaging of trabecular bone in the wrist at 3 tesla: Initial results
    Ludescher, B
    Martirosian, P
    Lenk, S
    Machann, J
    Dammann, F
    Schick, F
    Claussen, C
    Schlemmer, H
    ACTA RADIOLOGICA, 2005, 46 (03) : 306 - 309