摘要
Synchrotron-based digital radiography and microtomography devices are powerful, nondestructive, high-resolution research tools. In this paper, we present a linear system with a pixel size of 22.5 mu m and a field-of-view (FOV) 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified electron-bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device with 18 cm travel range. The total FOV obtained this way is 13 cm long and 18 cm high. The aim of this paper is to demonstrate the feasibility of this system to investigate a large area of a bone and to calculate the appropriate histomorphometric parameters. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste, Italy. A monochromatic 34-keV beam has been used for imaging a human proximal femur, about 9 cm in width, with our system. The reconstructed images (13 cm x 13 cm) were cross sections containing femoral head, femoral neck, and greater trochanter. The local variations in trabecular and cortical structure of the examined bone were clearly visible at a level not obtainable with medical CT scanners. The used spatial resolution allowed the visualization of thin trabeculae, which typically lie in a range of 100 mu m or lower. The quality of the reconstructed cross-section images confirmed that the system presented is a novel tool for high resolution three-dimensional (3-D) imaging of bone structure, with a pixel size over a volume of interest not achievable with conventional microCT scanners.
引用
收藏
页码:2584 / 2590
页数:7
相关论文
共 50 条
  • [1] A CCD-based high resolution CT system for analysis of trabecular bone tissue
    Pasini, A
    Baruffaldi, F
    Bettuzzi, M
    Brancaccio, R
    Casali, F
    Cornacchia, S
    Lanconelli, N
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2273 - 2277
  • [2] A CCD-based tissue imaging system
    MacDonald, JH
    Wells, K
    Reader, AJ
    Ott, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 220 - 226
  • [3] Evaluation of a CCD-based tissue imaging system
    MacDonald, JH
    Wells, K
    Ott, RJ
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1458 - 1461
  • [4] CCD-based high resolution digital radiography system for non destructive evaluation
    Nagarkar, VV
    Gordon, JS
    Gupta, TK
    Vasile, S
    Gothoskar, P
    Squillante, MR
    Entine, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 885 - 889
  • [5] CCD-based high resolution digital radiography system for non destructive evaluation
    Nagarkar, VV
    Gordon, JS
    Gupta, TK
    Vasile, S
    Gothoskar, P
    Entine, G
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 246 - 250
  • [6] A New High-Resolution Computed Tomography (CT) Segmentation Method for Trabecular Bone Architectural Analysis
    Scherf, Heike
    Tilgner, Rico
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2009, 140 (01) : 39 - 51
  • [7] High-resolution Counting System based on DSP and CCD
    Qi Xiao-guang
    Sui Xiu-wu
    Li Da-peng
    CONFERENCE ON MODELING, IDENTIFICATION AND CONTROL, 2012, 3 : 501 - 507
  • [8] Large area high-resolution CCD-based X-ray detector for macromolecular crystallography
    Pokric, M
    Allinson, NM
    Jorden, AR
    Cox, MP
    Marshall, A
    Long, PG
    Moon, K
    Jerram, P
    Pool, P
    Nave, C
    Derbyshire, GE
    Helliwell, JR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 166 - 171
  • [9] LA-iQID: A novel high-resolution CCD-based gamma camera for lymphatic imaging
    Han, Ling
    Miller, Brian W.
    Furenlid, Lars R.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [10] Time and Frequency Domain CCD-Based Thermoreflectance Techniques for High-Resolution Transient Thermal Imaging
    Vermeersch, B.
    Christofferson, J.
    Maize, K.
    Shakouri, A.
    De Mey, G.
    26TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2010, 2010, : 228 - 234