An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue

被引:10
|
作者
Baruffaldi, F. [1 ]
Beituzzi, M.
Bianconi, D.
Brancaccio, R.
Cornacchia, S.
Lanconelli, N.
Mancini, L.
Morigi, M. P.
Pasini, A.
Perilli, E.
Romani, D.
Rossi, A.
Casali, E.
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Univ Bologna, Dept Phys, I-40127 Bologna, Italy
[3] Ist Nazl Fis Nucl, I-40127 Bologna, Italy
[4] Trieste SCpA, I-34012 Trieste, Italy
[5] Univ Bologna, Dept Elect Comp Sci & Syst, I-40136 Bologna, Italy
关键词
biomedical; X-ray detectors; X-ray tomography;
D O I
10.1109/TNS.2006.876047
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Synchrotron-based digital radiography and microtomography devices are powerful, nondestructive, high-resolution research tools. In this paper, we present a linear system with a pixel size of 22.5 mu m and a field-of-view (FOV) 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified electron-bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device with 18 cm travel range. The total FOV obtained this way is 13 cm long and 18 cm high. The aim of this paper is to demonstrate the feasibility of this system to investigate a large area of a bone and to calculate the appropriate histomorphometric parameters. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste, Italy. A monochromatic 34-keV beam has been used for imaging a human proximal femur, about 9 cm in width, with our system. The reconstructed images (13 cm x 13 cm) were cross sections containing femoral head, femoral neck, and greater trochanter. The local variations in trabecular and cortical structure of the examined bone were clearly visible at a level not obtainable with medical CT scanners. The used spatial resolution allowed the visualization of thin trabeculae, which typically lie in a range of 100 mu m or lower. The quality of the reconstructed cross-section images confirmed that the system presented is a novel tool for high resolution three-dimensional (3-D) imaging of bone structure, with a pixel size over a volume of interest not achievable with conventional microCT scanners.
引用
收藏
页码:2584 / 2590
页数:7
相关论文
共 50 条
  • [31] Convergence behavior of high-resolution finite element models of trabecular bone
    Niebur, G.L.
    Yuen, J.C.
    Hsia, A.C.
    Keaveny, T.M.
    Journal of Biomechanical Engineering, 1999, 121 (06): : 629 - 635
  • [32] Convergence behavior of high-resolution finite element models of trabecular bone
    Niebur, GL
    Yuen, JC
    Hsia, AC
    Keaveny, TM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (06): : 629 - 635
  • [33] Automatic Prospective Registration of High-Resolution Trabecular Bone Images of the Tibia
    Janet Blumenfeld
    Julio Carballido-Gamio
    Roland Krug
    Daniel J. Blezek
    Ileana Hancu
    Sharmila Majumdar
    Annals of Biomedical Engineering, 2007, 35 : 1924 - 1931
  • [34] Automatic prospective registration of high-resolution trabecular bone images of the tibia
    Blumenfeld, Janet
    Carballido-Gamio, Julio
    Krug, Roland
    Blezek, Daniel J.
    Hancu, Ileana
    Majumdar, Sharmila
    ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (11) : 1924 - 1931
  • [35] Deep Learning Based High-Resolution Reconstruction of Trabecular Bone Microstructures from Low-Resolution CT Scans using GAN- CIRCLE
    Guha, Indranil
    Nadeem, Syed Ahmed
    You, Chenyu
    Zhang, Xiaoliu
    Levy, Steven M.
    Wang, Ge
    Torner, James C.
    Saha, Punam K.
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [36] CT ANATOMY OF THE SPHENOID BONE UTILIZING A HIGH-RESOLUTION PARTIAL SCANNING SYSTEM
    GEORGE, A
    THORN, J
    KOSLOW, M
    CHASE, N
    BERGERON, RT
    ABELE, M
    GRIFFITH, R
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1980, 1 (01) : 121 - 121
  • [37] High-resolution MRI vs multislice spiral CT: Which technique depicts the trabecular bone structure best?
    Thomas M. Link
    Volker Vieth
    Christoph Stehling
    Albrecht Lotter
    Ambros Beer
    David Newitt
    Sharmila Majumdar
    European Radiology, 2003, 13 : 663 - 671
  • [38] High-resolution MRI vs multislice spiral CT: Which technique depicts the trabecular bone structure best?
    Link, TM
    Vieth, V
    Stehling, C
    Lotter, A
    Beer, A
    Newitt, D
    Majumdar, S
    EUROPEAN RADIOLOGY, 2003, 13 (04) : 663 - 671
  • [39] PARAGANGLIOMAS OF THE TEMPORAL BONE - HIGH-RESOLUTION CT STUDIES
    CHAKERES, DW
    LAMASTERS, DL
    RADIOLOGY, 1984, 150 (03) : 749 - 753
  • [40] HIGH-RESOLUTION CT OF THE TEMPORAL BONE, NORMAL AND PATHOLOGIC
    TAYLOR, S
    BOIES, L
    HILGER, P
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1982, 3 (01) : 92 - 92