Estimation of central systolic blood pressure using an oscillometric blood pressure monitor

被引:0
|
作者
Hao-Min Cheng
Kang-Ling Wang
Ying-Hwa Chen
Shing-Jong Lin
Lung-Ching Chen
Shih-Hsien Sung
Philip Yu-An Ding
Wen-Chung Yu
Jaw-Wen Chen
Chen-Huan Chen
机构
[1] Taipei Veterans General Hospital,Department of Medical Research and Education
[2] National Yang-Ming University,Department of Medicine
[3] Taipei Veterans General Hospital,Department of Research and Education
[4] Cardiovascular Research Center,undefined
[5] National Yang-Ming University,undefined
来源
Hypertension Research | 2010年 / 33卷
关键词
central blood pressure; oscillometric signals; pressure wave reflection; pulse volume plethysmography;
D O I
暂无
中图分类号
学科分类号
摘要
Current noninvasive techniques for assessing central aortic pressure require the recording of an arterial pressure wave using a high-fidelity applanation tonometer. We therefore developed and validated a novel method to estimate the central aortic systolic pressure using an oscillometric blood pressure monitor alone. Invasive high-fidelity right brachial and central aortic pressure waves, and left-brachial pulse volume plethysmography from an oscillometric blood pressure monitor, were obtained at baseline and 3 min after administration of sublingual nitroglycerin in 100 patients during cardiac catheterization. In the initial 50 patients (Generation Group), Central systolic blood pressure was predicted by a multi-variate prediction model generated from the comprehensive analysis of the invasive brachial pressure wave, including brachial late-systolic shoulder pressure value and parameters related to wave reflection and arterial compliance. Another prediction model was similarly constructed from the noninvasively calibrated pulse volume plethysmography. Both models were validated in the subsequent 50 patients (Validation Group) with results: r=0.98 (P<0.001) and mean difference=0.5±4.5 (95% confidence interval −8.3 to 9.3) mm Hg for the invasive model, and r=0.93 (P<0.001) and mean difference=−0.1±7.6 (95% confidence interval −15.0 to 14.8) mm Hg for the noninvasive model. Thus, our results indicate that central aortic systolic blood pressure could be estimated by analysis of the noninvasive brachial pressure wave alone from an oscillometric blood pressure monitor.
引用
收藏
页码:592 / 599
页数:7
相关论文
共 50 条
  • [21] Oscillometric blood pressure measurements on smartphones using vibrometric force estimation
    Barry, Colin
    Xuan, Yinan
    Fascetti, Ava
    Moore, Alison
    Wang, Edward Jay
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Estimation of central systolic blood pressure from the late systolic shoulder of the digital artery pressure waveform
    Guilcher, A.
    Brett, S.
    Munir, S.
    Clapp, B.
    Chowienczyk, P.
    JOURNAL OF HYPERTENSION, 2008, 26 : S506 - S506
  • [23] Estimation of Blood Pressure Measurements for Hypertension Diagnosis Using Oscillometric Method
    Shin, Youngsuk
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2011, E94A (02) : 806 - 812
  • [24] Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor
    Youjung Seo
    Saehim Kwon
    Unang Sunarya
    Sungmin Park
    Kwangsuk Park
    Dawoon Jung
    Youngho Cho
    Cheolsoo Park
    Biomedical Engineering Letters, 2023, 13 : 221 - 233
  • [25] Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor
    Seo, Youjung
    Kwon, Saehim
    Sunarya, Unang
    Park, Sungmin
    Park, Kwangsuk
    Jung, Dawoon
    Cho, Youngho
    Park, Cheolsoo
    BIOMEDICAL ENGINEERING LETTERS, 2023, 13 (02) : 221 - 233
  • [26] Is Noninvasive Brachial Systolic Blood Pressure an Accurate Estimate of Central Aortic Systolic Blood Pressure?
    Shih, Yuan-Ta
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Chuang, Shao-Yuan
    Hu, Wei-Chih
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (11) : 1283 - 1291
  • [27] Oscillometric blood pressure estimation: Past, present, and future
    School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa
    K1N 6N5, Canada
    不详
    MA
    02138, United States
    IEEE Rev. Biomed. Eng., (44-63):
  • [28] Model-Based Oscillometric Blood Pressure Estimation
    Forouzanfar, Mohamad
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 443 - 448
  • [29] Systolic Blood Pressure at End-Expiration Measured by the Automated Systolic Pressure Variation Monitor is Equivalent to Systolic Blood Pressure during Apnea
    Howard A. Schwid
    G. Alec Rooke
    Journal of Clinical Monitoring and Computing, 2000, 16 : 115 - 120
  • [30] Oscillometric Blood Pressure Estimation Based on Deep Learning
    Lee, Soojeong
    Chang, Joon-Hyuk
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2017, 13 (02) : 461 - 472