A 0.36 μW/channel recorder for external ambulatory ECG recorders

被引:0
|
作者
Yasser Rezaeiyan
Omid Shoaei
机构
[1] University of Tehran,School of Electrical and Computer Engineering
关键词
Analog integrated circuits; Instrumentation amplifier; Low power; ECG; Modulator; Programmable gain amp;
D O I
暂无
中图分类号
学科分类号
摘要
There is an increasing demand for long-term ECG monitoring applications which are very low power, small size and capable of wireless data transmission. This paper presents an analog front-end and also modulator for long-term ECG recording purpose. The fully integrated system features three independent channels and a modulator. The analog front-end includes a voltage-to-time conversion and a tunable modulator to achieve a very low power consumption for wireless transmission of the data without analog to digital converter. The proposed system is designed and simulated in a 0.18μm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.18\,\upmu \hbox {m}$$\end{document} CMOS technology and occupies only 0.245mm2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.245\,\mathrm{mm}^{2}$$\end{document}. It can record ECG signal with 9.2-bit resolution while consuming only 0.36μW\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.36\,\upmu {\mathrm{W}}$$\end{document} per channel from a 0.9 V supply. Also, it can transmit data consuming just 0.72μW\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.72\,{\upmu }\mathrm{W}$$\end{document} per channel from a 0.9 V supply. The input referred noise of the readout channel is 2.01μVrms\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$2.01\,\upmu {\mathrm{V}}_{{{\rm rms}}}$$\end{document}.
引用
收藏
页码:17 / 29
页数:12
相关论文
共 38 条
  • [1] A 0.36 μW/channel recorder for external ambulatory ECG recorders
    Rezaeiyan, Yasser
    Shoaei, Omid
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2018, 95 (01) : 17 - 29
  • [2] A 0.5 μA/Channel front-end for implantable and external ambulatory ECG recorders
    Rezaeiyan, Yasser
    Zamani, Milad
    Shoaei, Omid
    Serdijn, Wouter A.
    MICROELECTRONICS JOURNAL, 2018, 74 : 79 - 85
  • [3] Indications for the use of diagnostic implantable and external ECG loop recorders
    Brignole, Michele
    Vardas, Panos
    Hoffman, Ellen
    Huikuri, Heikki
    Moya, Angel
    Ricci, Renato
    Sulke, Neil
    Wieling, Wouter
    Auricchio, Angelo
    Lip, Gregory Y. H.
    Almendral, Jesus
    Kirchhof, Paulus
    Aliot, Etienne
    Gasparini, Maurizio
    Braunschweig, Frieder
    EUROPACE, 2009, 11 (05): : 671 - 687
  • [4] NEED FOR ECG CHANNEL IN AMBULATORY EEG
    STEPHENSON, JBP
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (03): : S137 - S137
  • [5] AMBULATORY ECG MONITORING - IMPORTANCE OF A SECOND CHANNEL
    BELIC, N
    GARDIN, JM
    SINGER, D
    CLINICAL RESEARCH, 1979, 27 (02): : A153 - A153
  • [6] Design and implementation of a digital ambulatory ECG recorder based on flash multimediacard memory
    Deniz, T
    Yilmaz, A
    Proceedings of the 46th IEEE International Midwest Symposium on Circuits & Systems, Vols 1-3, 2003, : 368 - 371
  • [7] Diagnostic Yield of a 14 Day Ambulatory ECG Recorder in Patients With Suspected Syncope
    Keibel, Andrew
    Carlson, Steven
    Saxon, Leslie
    Chang, Philip
    Doshi, Rahul
    Shinbane, Jerold
    Huntsinger, Mary
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (08) : S43 - S43
  • [8] Precordial electrode placement for optimal ECG monitoring: Implications for ambulatory monitor devices and event recorders
    Nedios, Sotirios
    Romero, Inaki
    Gerds-Li, Jin-Hong
    Fleck, Eckard
    Kriatselis, Charalampos
    JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (05) : 669 - 676
  • [9] A 16-CHANNEL AMBULATORY EEG CASSETTE RECORDER - TECHNICAL PROPERTIES
    IVES, JR
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 57 (01): : P6 - P6
  • [10] Reliability of an external loop recorder for automatic recognition and transtelephonic ECG transmission of atrial fibrillation
    Mueller, Axel
    Scharner, Wilfried
    Borchardt, Tilo
    Och, Wolfgang
    Korb, Harald
    JOURNAL OF TELEMEDICINE AND TELECARE, 2009, 15 (08) : 391 - 396