Precordial electrode placement for optimal ECG monitoring: Implications for ambulatory monitor devices and event recorders

被引:20
|
作者
Nedios, Sotirios [1 ]
Romero, Inaki [2 ]
Gerds-Li, Jin-Hong [3 ]
Fleck, Eckard [3 ]
Kriatselis, Charalampos [3 ]
机构
[1] Univ Leipzig, Ctr Heart, Dept Electrophysiol, D-04289 Leipzig, Germany
[2] Holst Ctr IMEC, Eindhoven, Netherlands
[3] German Heart Inst Berlin, Dept Internal Med & Cardiol, Berlin, Germany
关键词
Ambulatory; Patient monitoring; Electrocardiography (ECG); Atrial fibrillation; ATRIAL-FIBRILLATION; SURFACE ELECTROCARDIOGRAMS; DIAGNOSIS;
D O I
10.1016/j.jelectrocard.2014.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Detection of QRS complexes, P-waves and atrial fibrillation f-waves in electrocardiographic (ECG) signals is critical for the correct diagnosis of arrhythmias. We aimed to find the best bipolar lead (BL) with the highest signal amplitude and shortest inter-electrode spacing. Methods: ECG signals (120 seconds) were recorded in 36 patients with 16 precordial electrodes placed in a standardized pattern. An average signal was analysed for each of 120 possible BLs obtained by calculating the difference between pairs of unipolar leads. Peak-to-peak amplitudes of QRS waves (50 ms around R-peak) and P waves (270-70 ms before R-peak) were calculated. For patients with atrial fibrillation, power of the fibrillatory (f) wave was used instead. Maximum values at each distance were considered and differentiation analysis was performed based on incremental changes (amplitude to distance). Results: There was a significant correlation between distance and QRS-amplitude (r = 0.78, p < 0.001), P-wave amplitude (r = 0.60, p < 0.01) and f-wave power (r = 0.79, p < 0.001). The range of values was: QRS-amplitude 0.7-2.33 mV, P-wave amplitude 0.07-0.18 mV, and f-wave power 0.55-2.12 mV(2)/s. The maximum value for the shortest distance was on a heart-aligned axis over the left ventricle for the QRS complex (1.9 mV at 8.7 cm) and over the atria for the P-wave (0.98 mV) and f-waves (1.45 mV(2)/s at 8 cm, respectively). Conclusion: There is a strong positive correlation between electrode distance and ECG signal-amplitude. Distance of 8 cm on a heart-aligned axis and over the relevant heart-chamber provides the highest signal amplitude for the shortest distance. These findings are essential for the design and use of ambulatory monitoring devices. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:669 / 676
页数:8
相关论文
共 32 条
  • [1] Optimisation of Electrode Placement for New Ambulatory ECG Monitoring Devices
    Kennedy, Alan
    Finlay, Dewar D.
    Guldenring, Daniel
    Bond, Raymond
    Moran, Kieran
    McLaughlin, James
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 101 - 104
  • [2] Improving ECG Monitoring Electrode Placement
    Funk, Marjorie
    May, Jeanine
    Stephens, Kimberly
    Fennie, Kristopher
    Chang, Pei-Shiun
    Feder, Shelli
    Drew, Barbara
    NURSING RESEARCH, 2013, 62 (02) : E24 - E25
  • [3] OPTIMAL METHODOLOGY FOR AMBULATORY ECG MONITORING - CONTINUOUS OR SAMPLED RECORDING
    GRADMAN, AH
    JOURNAL OF CHRONIC DISEASES, 1984, 37 (04): : 243 - 244
  • [4] Influence of Electrode Placement on Signal Quality for Ambulatory Pregnancy Monitoring
    Rooijakkers, M. J.
    Song, S.
    Rabotti, C.
    Oei, S. G.
    Bergmans, J. W. M.
    Cantatore, E.
    Mischi, M.
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2014, 2014
  • [5] OPTIMAL ELECTRODE LOCATION FOR MONITORING THE ECG AND BREATHING IN NEONATES
    BAIRD, TM
    GOYDOS, JM
    NEUMAN, MR
    PEDIATRIC PULMONOLOGY, 1992, 12 (04) : 247 - 250
  • [6] Two-Electrode ECG for Ambulatory Monitoring with Minimal Hardware Complexity
    Babusiak, Branko
    Borik, Stefan
    Smondrk, Maros
    SENSORS, 2020, 20 (08)
  • [7] Validation of a novel single lead ambulatory ECG monitor - Cardiostat™ - Compared to a standard ECG Holter monitoring
    Nault, Isabelle
    Andre, Philippe
    Plourde, Benoit
    Leclerc, Francois
    Sarrazin, Jean-Francois
    Philippon, Francois
    O'Hara, Gilles
    Molin, Franck
    Steinberg, Christian
    Roy, Karine
    Blier, Louis
    Champagne, Jean
    JOURNAL OF ELECTROCARDIOLOGY, 2019, 53 : 57 - 63
  • [8] OPTIMAL METHODOLOGY FOR AMBULATORY ECG MONITORING - CONTINUOUS OR SAMPLED RECORDING - REPLY
    CROW, RS
    JACOBS, DR
    HANNAN, P
    HAMM, L
    JOURNAL OF CHRONIC DISEASES, 1984, 37 (04): : 245 - 246
  • [9] On Optimal Placement of the Monitoring Devices on Channels of Communication Network
    Rodionov, Alexey
    Sokolova, Olga
    Yurgenson, Anastasia
    Choo, Hyunseung
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2009, PT II, 2009, 5593 : 465 - +
  • [10] INITIAL REAL WORLD AND CLINICAL EXPERIENCE OF THE NEXT GENERATION AMBULATORY ECG ZIO MONITOR: IMPLICATIONS FOR STANDARD AND EXTENDED WEAR MONITORING
    Alexander, Jay H.
    Hsu, Mike
    Ellis, Jeffrey
    Muresan, Adina
    Bame, Charlotte
    Wilk, Alan
    Crosson, Lori
    Clarkson, Kevin
    Day, Mark
    Turakhia, Mintu
    Lenane, Judith C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 2122 - 2122