Precordial electrode placement for optimal ECG monitoring: Implications for ambulatory monitor devices and event recorders

被引:20
|
作者
Nedios, Sotirios [1 ]
Romero, Inaki [2 ]
Gerds-Li, Jin-Hong [3 ]
Fleck, Eckard [3 ]
Kriatselis, Charalampos [3 ]
机构
[1] Univ Leipzig, Ctr Heart, Dept Electrophysiol, D-04289 Leipzig, Germany
[2] Holst Ctr IMEC, Eindhoven, Netherlands
[3] German Heart Inst Berlin, Dept Internal Med & Cardiol, Berlin, Germany
关键词
Ambulatory; Patient monitoring; Electrocardiography (ECG); Atrial fibrillation; ATRIAL-FIBRILLATION; SURFACE ELECTROCARDIOGRAMS; DIAGNOSIS;
D O I
10.1016/j.jelectrocard.2014.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Detection of QRS complexes, P-waves and atrial fibrillation f-waves in electrocardiographic (ECG) signals is critical for the correct diagnosis of arrhythmias. We aimed to find the best bipolar lead (BL) with the highest signal amplitude and shortest inter-electrode spacing. Methods: ECG signals (120 seconds) were recorded in 36 patients with 16 precordial electrodes placed in a standardized pattern. An average signal was analysed for each of 120 possible BLs obtained by calculating the difference between pairs of unipolar leads. Peak-to-peak amplitudes of QRS waves (50 ms around R-peak) and P waves (270-70 ms before R-peak) were calculated. For patients with atrial fibrillation, power of the fibrillatory (f) wave was used instead. Maximum values at each distance were considered and differentiation analysis was performed based on incremental changes (amplitude to distance). Results: There was a significant correlation between distance and QRS-amplitude (r = 0.78, p < 0.001), P-wave amplitude (r = 0.60, p < 0.01) and f-wave power (r = 0.79, p < 0.001). The range of values was: QRS-amplitude 0.7-2.33 mV, P-wave amplitude 0.07-0.18 mV, and f-wave power 0.55-2.12 mV(2)/s. The maximum value for the shortest distance was on a heart-aligned axis over the left ventricle for the QRS complex (1.9 mV at 8.7 cm) and over the atria for the P-wave (0.98 mV) and f-waves (1.45 mV(2)/s at 8 cm, respectively). Conclusion: There is a strong positive correlation between electrode distance and ECG signal-amplitude. Distance of 8 cm on a heart-aligned axis and over the relevant heart-chamber provides the highest signal amplitude for the shortest distance. These findings are essential for the design and use of ambulatory monitoring devices. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:669 / 676
页数:8
相关论文
共 32 条
  • [31] Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms
    Martinek, Radek
    Kahankova, Radana
    Nazeran, Homer
    Konecny, Jaromir
    Jezewski, Janusz
    Janku, Petr
    Bilik, Petr
    Zidek, Jan
    Nedoma, Jan
    Fajkus, Marcel
    SENSORS, 2017, 17 (05)
  • [32] Improvement of in-hospital telemetry monitoring in coronary care units: An intervention study for achieving optimal electrode placement and attachment, hygiene and delivery of critical information to patients
    Pettersen, Trond R.
    Falun, Nina
    Norekval, Tone M.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2014, 13 (06) : 515 - 523