A 0.36 μW/channel recorder for external ambulatory ECG recorders

被引:0
|
作者
Yasser Rezaeiyan
Omid Shoaei
机构
[1] University of Tehran,School of Electrical and Computer Engineering
关键词
Analog integrated circuits; Instrumentation amplifier; Low power; ECG; Modulator; Programmable gain amp;
D O I
暂无
中图分类号
学科分类号
摘要
There is an increasing demand for long-term ECG monitoring applications which are very low power, small size and capable of wireless data transmission. This paper presents an analog front-end and also modulator for long-term ECG recording purpose. The fully integrated system features three independent channels and a modulator. The analog front-end includes a voltage-to-time conversion and a tunable modulator to achieve a very low power consumption for wireless transmission of the data without analog to digital converter. The proposed system is designed and simulated in a 0.18μm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.18\,\upmu \hbox {m}$$\end{document} CMOS technology and occupies only 0.245mm2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.245\,\mathrm{mm}^{2}$$\end{document}. It can record ECG signal with 9.2-bit resolution while consuming only 0.36μW\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.36\,\upmu {\mathrm{W}}$$\end{document} per channel from a 0.9 V supply. Also, it can transmit data consuming just 0.72μW\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.72\,{\upmu }\mathrm{W}$$\end{document} per channel from a 0.9 V supply. The input referred noise of the readout channel is 2.01μVrms\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$2.01\,\upmu {\mathrm{V}}_{{{\rm rms}}}$$\end{document}.
引用
收藏
页码:17 / 29
页数:12
相关论文
共 38 条
  • [31] CEEMDAN-IMFx-PCA-CICA: an improved single-channel blind source separation in multimedia environment for motion artifact reduction in ambulatory ECG
    Xiong, Fan
    Chen, Dongyi
    COMPLEX & INTELLIGENT SYSTEMS, 2023, 9 (03) : 2555 - 2569
  • [32] CEEMDAN-IMFx-PCA-CICA: an improved single-channel blind source separation in multimedia environment for motion artifact reduction in ambulatory ECG
    Fan Xiong
    Dongyi Chen
    Complex & Intelligent Systems, 2023, 9 : 2555 - 2569
  • [33] A 20μW Dual-Channel Analog Front-End in 65nm CMOS for Portable ECG Monitoring System
    Li, Shuo
    Qi, Nan
    Behravan, Vahid
    Hong, Zhiliang
    Chiang, Patrick Y.
    PROCEEDINGS OF 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2015,
  • [34] Using the net benefit regression framework to construct cost-effectiveness acceptability curves: an example using data from a trial of external loop recorders versus Holter monitoring for ambulatory monitoring of "community acquired" syncope
    Hoch, Jeffrey S.
    Rockx, Marie Antoinette
    Krahn, Andrew D.
    BMC HEALTH SERVICES RESEARCH, 2006, 6 (1)
  • [35] Using the net benefit regression framework to construct cost-effectiveness acceptability curves: an example using data from a trial of external loop recorders versus Holter monitoring for ambulatory monitoring of "community acquired" syncope
    Jeffrey S Hoch
    Marie Antoinette Rockx
    Andrew D Krahn
    BMC Health Services Research, 6
  • [36] A 345 μW Multi-Sensor Biomedical SoC With Bio-Impedance, 3-Channel ECG, Motion Artifact Reduction, and Integrated DSP
    Van Helleputte, Nick
    Konijnenburg, Mario
    Pettine, Julia
    Jee, Dong-Woo
    Kim, Hyejung
    Morgado, Alonso
    Van Wegberg, Roland
    Torfs, Tom
    Mohan, Rachit
    Breeschoten, Arjan
    de Groot, Harmke
    Van Hoof, Chris
    Yazicioglu, Refet Firat
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2015, 50 (01) : 230 - 244
  • [37] An 18.6-μW/Ch TDM-Based 8-Channel Noncontact ECG Recording IC With Common-Mode Interference Suppression
    Choi, Kyu-Jin
    Sim, Jae-Yoon
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2022, 16 (06) : 1021 - 1029
  • [38] External barium influences the gating conformational changes of the non-conducting and non-inactivating Shaker K+ channel, ShH4-IR W434F.
    Hurst, RS
    Roux, MJ
    Toro, L
    Stefani, E
    BIOPHYSICAL JOURNAL, 1996, 70 (02) : MPMA6 - MPMA6