A pilot study for intraocular pressure measurements based on vibroacoustic parameters

被引:0
|
作者
Deukha Kim
Youngbeen Chung
Yeji Yeon
Hyunsoo Cho
Han Woong Lim
Junhong Park
Won June Lee
机构
[1] Hanyang University College of Engineering,Department of Mechanical Engineering
[2] Hanyang University College of Medicine,Department of Ophthalmology
[3] Hanyang University Seoul Hospital,Department of Ophthalmology
来源
Scientific Reports | / 11卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The present study aimed to identify vibroacoustic properties associated with intraocular pressure (IOP) changes and to suggest a new way to measure the IOP based on these properties. Ten ex vivo porcine eyeballs were used in this study. Each eyeball was fixated in a central hole of a Styrofoam block, and vibration applied to the Styrofoam block was transmitted to the eyeball. An accelerometer directly attached to the eyeball measured the vibration response. Excitations and measurements were performed for 1 s, and the excitation magnitude was varied for the same signal in repeat measurements. A 30-gauge needle was inserted into the anterior chamber of the eyeball to inject a balanced salt solution, and the height of the bottle was adjusted to adjust the IOP. A tonometer was used under identical conditions to measure the IOP five times, and the mean value was determined for further analyses. The measurements showed that the parameters resonance frequency and change in the magnitude of the vibration response (CMVR) increased with rising IOP values. The CMVR was highly correlated with the IOP (p-value < 0.0001). A linear mixed effects model (LMM) was used as a statistical analysis method. We confirmed that vibroacoustic properties of the eyeball are correlated with IOP changes. It is expected that the CMVR will serve as a new parameter for IOP measurements. Thus, in the future, continuous IOP measurements would be easily performed using the CMVR.
引用
收藏
相关论文
共 50 条
  • [41] Injectable intraocular telescope: Pilot study
    Qureshi, Muhammad A.
    Robbie, Scott J.
    Tabernero, Juan
    Artal, Pablo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2125 - 2135
  • [42] A PRACTICE BASED STUDY OF FACTORS INFLUENCING INTRAOCULAR-PRESSURE
    MCCAGHREY, FE
    MCCAGHREY, GE
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1991, 11 (03) : 195 - 200
  • [43] The effect of baseline intraocular pressure and anterior segment parameters on intraocular pressure after intravitreal bevacizumab injection
    Ozcan, Zeynep Ozer
    Soysal, Gizem Gurbostan
    Tiskaoglu, Nesime Setge
    Berhuni, Mustafa
    CUTANEOUS AND OCULAR TOXICOLOGY, 2023, 42 (04) : 248 - 252
  • [44] Visual acuity and intraocular pressure measurements: Is there a systemic bias in measurement? A UK multicentre study
    Soomro, Taha
    Thomas, Darren
    Schwartz, Roy
    Warwick, Alasdair
    Olvera-Barrios, Abraham
    Gazzard, Gus
    Tufail, Adnan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [45] The association of anxiety and insomnia on blood pressure parameters in pregnancy: a pilot study
    Miller, Hayley E.
    Simpson, Samantha L.
    Hurtado, Janet
    Boncompagni, Ana C.
    Chueh, Jane
    Druzin, Maurice L.
    Panelli, Danielle M.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S483 - S484
  • [46] Intraocular Pressure Measurements in Standing Position with a Rebound Tonometer
    De Bernardo, Maddalena
    Borrelli, Maria
    Cembalo, Giovanni
    Rosa, Nicola
    MEDICINA-LITHUANIA, 2019, 55 (10):
  • [47] MEASUREMENTS OF INTRAOCULAR-PRESSURE IN INFANTS WITHOUT GLAUCOMA
    GROTE, P
    OPHTHALMOLOGICA, 1975, 171 (03) : 202 - 206
  • [48] Non-invasive Intraocular Pressure Measurements in Zebrafish
    Cameron, D. Joshua
    Davey, Pinakin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [49] A portable applanation tonometer for accurate intraocular pressure measurements
    Feng, Tingting
    Chen, Xinjian
    Geng, Jialei
    Nie, Baoqing
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 344
  • [50] Mechanical eye model for evaluating intraocular pressure measurements
    Saleh K.
    Unger V.
    Dietzel A.
    Heydenreich D.
    Großjohann R.
    Jürgens C.
    Tost F.
    Haueisen J.
    Biomedical Engineering Letters, 2014, 4 (4) : 396 - 402