A pilot study for intraocular pressure measurements based on vibroacoustic parameters

被引:0
|
作者
Deukha Kim
Youngbeen Chung
Yeji Yeon
Hyunsoo Cho
Han Woong Lim
Junhong Park
Won June Lee
机构
[1] Hanyang University College of Engineering,Department of Mechanical Engineering
[2] Hanyang University College of Medicine,Department of Ophthalmology
[3] Hanyang University Seoul Hospital,Department of Ophthalmology
来源
Scientific Reports | / 11卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The present study aimed to identify vibroacoustic properties associated with intraocular pressure (IOP) changes and to suggest a new way to measure the IOP based on these properties. Ten ex vivo porcine eyeballs were used in this study. Each eyeball was fixated in a central hole of a Styrofoam block, and vibration applied to the Styrofoam block was transmitted to the eyeball. An accelerometer directly attached to the eyeball measured the vibration response. Excitations and measurements were performed for 1 s, and the excitation magnitude was varied for the same signal in repeat measurements. A 30-gauge needle was inserted into the anterior chamber of the eyeball to inject a balanced salt solution, and the height of the bottle was adjusted to adjust the IOP. A tonometer was used under identical conditions to measure the IOP five times, and the mean value was determined for further analyses. The measurements showed that the parameters resonance frequency and change in the magnitude of the vibration response (CMVR) increased with rising IOP values. The CMVR was highly correlated with the IOP (p-value < 0.0001). A linear mixed effects model (LMM) was used as a statistical analysis method. We confirmed that vibroacoustic properties of the eyeball are correlated with IOP changes. It is expected that the CMVR will serve as a new parameter for IOP measurements. Thus, in the future, continuous IOP measurements would be easily performed using the CMVR.
引用
收藏
相关论文
共 50 条
  • [21] Stop "Adjusting" Intraocular Pressure Measurements
    Brandt, James D.
    JAMA OPHTHALMOLOGY, 2017, 135 (06) : 608 - 609
  • [22] OPTIMIZATION OF AN INTERFEROMETRIC PRESSURE SENSOR FOR INTRAOCULAR PRESSURE MEASUREMENTS
    Phan, Alex
    Phuong Trung
    Trumpp, Julian
    Talke, Frank E.
    PROCEEDINGS OF THE ASME/JSME JOINT INTERNATIONAL CONFERENCE ON INFORMATION STORAGE AND PROCESSING SYSTEMS AND MICROMECHATRONICS FOR INFORMATION AND PRECISION EQUIPMENT, 2018, 2018,
  • [23] Losartan Potassium Oral Administration Decreased Intraocular Pressure in HumansA Pilot Study
    Ciro Costagliola
    Marco Verolino
    Gennarfrancesco Iaccarino
    Maria Leonarda De Rosa
    Marco Ciancaglini
    Leonardo Mastropasqua
    Clinical Drug Investigation, 1999, 17 : 329 - 332
  • [24] Effects of a single osteopathic manipulative treatment on intraocular pressure reduction: a pilot study
    King, Hollis H.
    Weinreb, Robert N.
    Walker, Evan
    Zangwill, Linda M.
    JOURNAL OF OSTEOPATHIC MEDICINE, 2025,
  • [25] Lateralized Raise in Intraocular Pressure During Electroconvulsive Therapy A Tonometry Pilot Study
    Vandeurzen, Jelle
    Vansteelandt, Kristof
    Lemmens, Sophie
    Sienaert, Pascal
    JOURNAL OF ECT, 2023, 39 (01) : 42 - 45
  • [26] Losartan potassium oral administration decreased intraocular pressure in humans - A pilot study
    Costagliola, C
    Verolino, M
    Iaccarino, G
    De Rosa, ML
    Ciancaglini, M
    Mastropasqua, L
    CLINICAL DRUG INVESTIGATION, 1999, 17 (04) : 329 - 332
  • [27] Static and Dynamic Measurements of Compliance and Driving Pressure: A Pilot Study
    Tawfik, Pierre
    Syed, Muhammad K. Hayat
    Elmufdi, Firas S.
    Evans, Michael D.
    Dries, David J.
    Marini, John J.
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [28] Intraocular pressure measurements throughout the 24 h
    Bagga, Harmohina
    Liu, John H. K.
    Weinreb, Robert N.
    CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (02) : 79 - 83
  • [29] Dynamic intraocular pressure measurements during vitrectomy
    Moorhead, LC
    Gardner, TW
    Lambert, HM
    O'Malley, RE
    Willis, AW
    Meharg, LS
    Moorhead, WD
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (11) : 1514 - 1523
  • [30] Intraocular pressure measurements after conductive keratoplasty
    Kymionis, GD
    Naoumidi, TL
    Aslanides, IM
    Kumar, V
    Astyrakakis, NI
    Tsilimbaris, M
    Pallikaris, IG
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (02) : 171 - 175