Direct Dynamic Protein-Affinity Selection Mass-Spectrometry

被引:0
|
作者
Niels Jonker
Henk Lingeman
Hubertus Irth
机构
[1] VU University Amsterdam,BioMolecular Analysis Group, Department of Chemistry, Faculty of Sciences
来源
Chromatographia | 2010年 / 72卷
关键词
Column liquid chromatography; Protein affinity; Ligand screening; Dynamic immobilization; His-tagging; Estrogen receptor;
D O I
暂无
中图分类号
学科分类号
摘要
A new methodology is described enabling the affinity screening of potential ligands towards the human estrogen receptor alpha ligand binding domain (ERα-LBD). In-solution incubation is performed of the analyte and the His-tagged ERα-LBD. The bound complex is immobilized on a nickel-loaded protein-affinity selection column, where after the unbound fraction is removed. The immobilized protein–ligand complex is exposed to a decreased pH value and an increased organic modifier concentration releasing the ligand for MS detection, and precipitating the proteins on a filter positioned between the affinity column and the mass spectrometer. The trapping column can be regenerated for reuse at least 70 times. The advantages of the methodology over existing methodologies are the absence of a pre-concentration as well as a chromatographic separation step, resulting in a significantly shorter analysis time compared to previously described procedures, and in addition, allowing the determination of solutes with unfavorable chromatographic properties. The overall analysis time now can be reduced about 250% to approximately 6 min. Replacing the filters after every measurement results in an intra-day standard deviation of 14.8% and an inter-day standard deviation of 21.3%.
引用
收藏
页码:7 / 13
页数:6
相关论文
共 50 条
  • [41] Metabolite-protein interactions: Native mass spectrometry and collision induced affinity selection mass spectrometry in natural product screening
    Gu, Yushu
    Liu, Miaomiao
    Quinn, Ronald J.
    FRONTIERS IN ANALYTICAL SCIENCE, 2022, 2
  • [42] FAB MASS-SPECTROMETRY IN GENE AND PROTEIN DESIGN
    GROTJAHN, L
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 43 - ANYL
  • [43] DIRECT SUPERCRITICAL FLUID INJECTION MASS-SPECTROMETRY OF TRICHOTHECENES
    SMITH, RD
    UDSETH, HR
    BIOMEDICAL MASS SPECTROMETRY, 1983, 10 (10): : 577 - 580
  • [44] ANALYSIS OF RETINOIDS BY DIRECT EXPOSURE PROBE MASS-SPECTROMETRY
    PAPA, VM
    HUPERT, J
    FRIEDMAN, H
    NG, PS
    ROBBINS, EF
    MOBARHAN, S
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12): : 323 - 325
  • [45] MEMBRANE INTERFACE FOR THE DIRECT COUPLING OF PYROLYSIS AND MASS-SPECTROMETRY
    VREEKEN, RJ
    HOURIET, R
    ANALYTICA CHIMICA ACTA, 1995, 313 (03) : 237 - 241
  • [46] RAPID ANALYSIS USING DIRECT SAMPLING MASS-SPECTROMETRY
    BUCHANAN, MV
    HETTICH, RL
    WISE, MB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 89 - FUEL
  • [47] DISCRIMINATION OF MICROORGANISMS USING DIRECT PROBE MASS-SPECTROMETRY
    PUCKEY, DJ
    NORRIS, JR
    GUTTERIDGE, CS
    JOURNAL OF GENERAL MICROBIOLOGY, 1980, 118 (JUN): : 535 - 538
  • [48] DIRECT MASS-SPECTROMETRY OF STEROIDS IN GAS CHROMATOGRAPHY EFFLUENTS
    RYHAGE, R
    SJOVALL, J
    BIOCHEMICAL JOURNAL, 1964, 92 (01) : P2 - &
  • [49] DIRECT ANALYSIS OF MIXTURES BY DOUBLE QUADRUPOLE MASS-SPECTROMETRY
    GLISH, GL
    COOKS, RG
    ANALYTICA CHIMICA ACTA, 1980, 119 (01) : 145 - 148
  • [50] DIRECT MIXTURE ANALYSIS BY TRIPLE QUADRUPOLE MASS-SPECTROMETRY
    YOST, RA
    ENKE, CG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (SEP): : 98 - 98