Direct Dynamic Protein-Affinity Selection Mass-Spectrometry

被引:0
|
作者
Niels Jonker
Henk Lingeman
Hubertus Irth
机构
[1] VU University Amsterdam,BioMolecular Analysis Group, Department of Chemistry, Faculty of Sciences
来源
Chromatographia | 2010年 / 72卷
关键词
Column liquid chromatography; Protein affinity; Ligand screening; Dynamic immobilization; His-tagging; Estrogen receptor;
D O I
暂无
中图分类号
学科分类号
摘要
A new methodology is described enabling the affinity screening of potential ligands towards the human estrogen receptor alpha ligand binding domain (ERα-LBD). In-solution incubation is performed of the analyte and the His-tagged ERα-LBD. The bound complex is immobilized on a nickel-loaded protein-affinity selection column, where after the unbound fraction is removed. The immobilized protein–ligand complex is exposed to a decreased pH value and an increased organic modifier concentration releasing the ligand for MS detection, and precipitating the proteins on a filter positioned between the affinity column and the mass spectrometer. The trapping column can be regenerated for reuse at least 70 times. The advantages of the methodology over existing methodologies are the absence of a pre-concentration as well as a chromatographic separation step, resulting in a significantly shorter analysis time compared to previously described procedures, and in addition, allowing the determination of solutes with unfavorable chromatographic properties. The overall analysis time now can be reduced about 250% to approximately 6 min. Replacing the filters after every measurement results in an intra-day standard deviation of 14.8% and an inter-day standard deviation of 21.3%.
引用
收藏
页码:7 / 13
页数:6
相关论文
共 50 条
  • [31] A DOUBLE QUADRUPOLE FOR MASS-SPECTROMETRY MASS-SPECTROMETRY
    ZAKETT, D
    COOKS, RG
    FIES, WJ
    ANALYTICA CHIMICA ACTA, 1980, 119 (01) : 129 - 135
  • [32] COLLISION REGION FOR MASS-SPECTROMETRY MASS-SPECTROMETRY
    GLISH, GL
    TODD, PJ
    ANALYTICAL CHEMISTRY, 1982, 54 (04) : 842 - 843
  • [33] PEPTIDE AND PROTEIN-ANALYSIS BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY AND CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    LOO, JA
    UDSETH, HR
    SMITH, RD
    ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) : 404 - 412
  • [34] ANALYSIS OF DYNAMIC BIOCHEMICAL PROCESSES BY MASS-SPECTROMETRY
    CAPRIOLI, RM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 113 - ANYL
  • [35] PALMITYLATION OF A G-PROTEIN COUPLED RECEPTOR - DIRECT ANALYSIS BY TANDEM MASS-SPECTROMETRY
    PAPAC, DI
    THORNBURG, KR
    BULLESBACH, EE
    CROUCH, RK
    KNAPP, DR
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1992, 267 (24) : 16889 - 16894
  • [36] Nanoprobe-based affinity mass spectrometry approach for direct target protein identification
    Lin, CC
    Chen, YJ
    Lin, PC
    Chien, YY
    Chen, SH
    Chang, YW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U262 - U262
  • [37] STUDY OF AN ACTINOMYCIN COMPLEX BY MASS-SPECTROMETRY MASS-SPECTROMETRY
    BARBER, M
    BELL, D
    MORRIS, M
    TETLER, L
    WOODS, M
    BYCROFT, BW
    MONAGHAN, JJ
    MORDEN, WE
    GREEN, BN
    TALANTA, 1988, 35 (08) : 605 - 611
  • [38] IDENTIFICATION OF AFLATOXINS BY QUADRUPOLE MASS-SPECTROMETRY MASS-SPECTROMETRY
    PLATTNER, RD
    BENNETT, GA
    STUBBLEFIELD, RD
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1984, 67 (04): : 734 - 738
  • [39] PROTEIN MASS-SPECTROMETRY - APPLICATIONS TO ANALYTICAL BIOTECHNOLOGY
    NGUYEN, DN
    BECKER, GW
    RIGGIN, RM
    JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) : 21 - 45
  • [40] THE CHARACTERIZATION OF PROTEIN GLYCOSYLATION BY TANDEM MASS-SPECTROMETRY
    BURLINGAME, AL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 72 - CARB