Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection

被引:0
|
作者
Juha K. A. Rinne
Seyedsadra Miri
Niku Oksala
Antti Vehkaoja
Jyrki Kössi
机构
[1] Päijät-Häme Central Hospital,Department of Surgery
[2] Tampere University,Finnish Cardiovascular Research Center
[3] Tampere University, Tampere
[4] Tampere University,Faculty of Medicine and Health Technology
[5] Tampere University Hospital,Vascular Centre
[6] PulseOn Ltd,undefined
关键词
Photoplethysmography; PPG; Holter monitor; Heart rate variability; Postoperative recovery; Inter-beat-intervals; RR intervals;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the accuracy of heart rate variability (HRV) parameters obtained with a wrist-worn photoplethysmography (PPG) monitor in patients recovering from minimally invasive colon resection to investigate whether PPG has potential in postoperative patient monitoring. 31 patients were monitored for three days or until discharge or reoperation using a wrist-worn PPG monitor (PulseOn, Finland) with a Holter monitor (Faros 360, Bittium Biosignals, Finland) as a reference measurement device. Beat-to-beat intervals (BBI) and HRV information collected by PPG were compared with RR intervals (RRI) and HRV obtained from the ECG reference after removing artefacts and ectopic beats. The beat-to-beat mean error (ME) and mean absolute error (MAE) of good quality heartbeat intervals obtained by wrist PPG were estimated as − 1.34 ms and 10.4 ms respectively. A significant variation in the accuracy of the HRV parameters was found. In the time domain, SDNN (9.11%), TRI (11.4%) and TINN (11.1%) were estimated with low relative MAE, while RMSSD (34.3%), pNN50 (139%) and NN50 (188%) had higher errors. The logarithmic parameters in the frequency domain (VLF Log, LF Log and HF Log) exhibited the lowest relative error, and for non-linear parameters, SD2 (7.5%), DFA α1 (8.25%) and DFA α2 (4.71%) were calculated much more accurately than SD1 (34.3%). The wrist PPG shows some potential for use in a clinical setting. The accuracy of several HRV parameters analyzed post hoc was found sufficient to be used in further studies concerning postoperative recovery of patients undergoing laparoscopic colon resection, although there were large errors in many common HRV parameters such as RMSSD, pNN50 and NN50, rendering them unusable.
引用
收藏
页码:45 / 53
页数:8
相关论文
共 46 条
  • [41] Accuracy and clinical utility of heart rate variability derived from a wearable heart rate monitor in patients undergoing major abdominal surgery
    Yang, James
    Ben-Menachem, Erez
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (02) : 433 - 443
  • [42] Evaluation Of Night Autonomic Nerve Activity Analyzed From Heart Rate Variability In Patients With COPD Showing Desaturation During Sleep
    Fujimoto, K.
    Yamazaki, H.
    Ura, M.
    Harada, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [43] Randomized Pilot Trial Using External Yarrow Liver Compress Applications With Metastatic Cancer Patients Suffering From Fatigue: Evaluation of Sympathetic Modulation by Heart Rate Variability Analysis
    Foucre, Clara
    Schulz, Steffen
    Stritter, Wiebke
    von Mackensen, Irina
    Luchte, Jacqueline
    Ivaki, Pune
    Voss, Andreas
    Ghadjar, Pirus
    Seifert, Georg
    INTEGRATIVE CANCER THERAPIES, 2022, 21
  • [44] Randomized Pilot Trial Using External Yarrow Liver Compress Applications With Metastatic Cancer Patients Suffering From Fatigue: Evaluation of Sympathetic Modulation by Heart Rate Variability Analysis
    Foucre, Clara
    Schulz, Steffen
    Stritter, Wiebke
    von Mackensen, Irina
    Luchte, Jacqueline
    Ivaki, Pune
    Voss, Andreas
    Ghadjar, Pirus
    Seifert, Georg
    INTEGRATIVE CANCER THERAPIES, 2022, 21
  • [45] Heart Rate Variability Evaluation in Patients With Long Standing Persistent Atrial Fibrillation Treated With Thoracoscopic Surgical Ablation With Ganglionic Plexi Ablation or Catheter Ablation - Recordings From Implantable Loop Recorder
    Khan, Habib R.
    Hnatkova, Katerina
    Kralj-Hans, Ines
    Jones, David G.
    Hussain, Wajid
    Jarman, Julian
    Cowie, Martin
    Markides, Vias
    Malik, Marek
    Wong, Tom
    CIRCULATION, 2017, 136
  • [46] The heart rate variability-derived Newborn Infant Parasympathetic Evaluation (NIPE™) Index in pediatric surgical patients from 0 to 2 years under sevoflurane anesthesia-A prospective observational pilot study
    Weber, Frank
    Roeleveld, Hilde G.
    Geerts, Noortje J. E.
    Warmenhoven, Annejet T.
    Schroder, Rosalie
    de Leeuw, Thomas G.
    PEDIATRIC ANESTHESIA, 2019, 29 (04) : 377 - 384