Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection

被引:0
|
作者
Juha K. A. Rinne
Seyedsadra Miri
Niku Oksala
Antti Vehkaoja
Jyrki Kössi
机构
[1] Päijät-Häme Central Hospital,Department of Surgery
[2] Tampere University,Finnish Cardiovascular Research Center
[3] Tampere University, Tampere
[4] Tampere University,Faculty of Medicine and Health Technology
[5] Tampere University Hospital,Vascular Centre
[6] PulseOn Ltd,undefined
关键词
Photoplethysmography; PPG; Holter monitor; Heart rate variability; Postoperative recovery; Inter-beat-intervals; RR intervals;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the accuracy of heart rate variability (HRV) parameters obtained with a wrist-worn photoplethysmography (PPG) monitor in patients recovering from minimally invasive colon resection to investigate whether PPG has potential in postoperative patient monitoring. 31 patients were monitored for three days or until discharge or reoperation using a wrist-worn PPG monitor (PulseOn, Finland) with a Holter monitor (Faros 360, Bittium Biosignals, Finland) as a reference measurement device. Beat-to-beat intervals (BBI) and HRV information collected by PPG were compared with RR intervals (RRI) and HRV obtained from the ECG reference after removing artefacts and ectopic beats. The beat-to-beat mean error (ME) and mean absolute error (MAE) of good quality heartbeat intervals obtained by wrist PPG were estimated as − 1.34 ms and 10.4 ms respectively. A significant variation in the accuracy of the HRV parameters was found. In the time domain, SDNN (9.11%), TRI (11.4%) and TINN (11.1%) were estimated with low relative MAE, while RMSSD (34.3%), pNN50 (139%) and NN50 (188%) had higher errors. The logarithmic parameters in the frequency domain (VLF Log, LF Log and HF Log) exhibited the lowest relative error, and for non-linear parameters, SD2 (7.5%), DFA α1 (8.25%) and DFA α2 (4.71%) were calculated much more accurately than SD1 (34.3%). The wrist PPG shows some potential for use in a clinical setting. The accuracy of several HRV parameters analyzed post hoc was found sufficient to be used in further studies concerning postoperative recovery of patients undergoing laparoscopic colon resection, although there were large errors in many common HRV parameters such as RMSSD, pNN50 and NN50, rendering them unusable.
引用
收藏
页码:45 / 53
页数:8
相关论文
共 46 条
  • [31] Heart rate variability in patients recovering from general anaesthesia
    Ireland, N
    Meagher, J
    Sleigh, JW
    Henderson, JD
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (05) : 657 - 662
  • [32] Heart Rate Measures From Wrist-Worn Activity Trackers in a Laboratory and Free-Living Setting: Validation Study
    Mueller, Andre Matthias
    Wang, Nan Xin
    Yao, Jiali
    Tan, Chuen Seng
    Low, Ivan Cherh Chiet
    Lim, Nicole
    Tan, Jeremy
    Tan, Agnes
    Mueller-Riemenschneider, Falk
    JMIR MHEALTH AND UHEALTH, 2019, 7 (10):
  • [33] Estimation of heart rate variability from heart rate measured with wristwatch-type heart rate monitor
    Yokoyama, Kiyoko
    Hayashi, Emi
    Ito, Hisatoshi
    Kawahara, Yuko
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2022, 105 (02)
  • [34] Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients
    Francesco Sartor
    Jos Gelissen
    Ralph van Dinther
    David Roovers
    Gabriele B. Papini
    Giuseppe Coppola
    BMC Sports Science, Medicine and Rehabilitation, 10
  • [35] Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients
    Sartor, Francesco
    Gelissen, Jos
    Van Dinther, Ralph
    Roovers, David
    Papini, Gabriele B.
    Coppola, Giuseppe
    BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2018, 10
  • [36] Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients
    Grubb, M. R.
    Carpenter, J.
    Crowe, J. A.
    Teoh, J.
    Marlow, N.
    Ward, C.
    Mann, C.
    Sharkey, D.
    Hayes-Gill, B. R.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (05) : 881 - 893
  • [37] Local Interval Estimation Improves Accuracy and Robustness of Heart Rate Variability Derivation from Photoplethysmography
    Antink, Christoph Hoog
    Leonhardt, Steffen
    Walter, Marian
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3558 - 3561
  • [38] Estimation of Heart Rate Variability from Heartrate Measured with Wristwatch-Type Heartrate Monitor
    Yokoyama K.
    Hayashi E.
    Ito H.
    Kawahara Y.
    IEEJ Transactions on Electronics, Information and Systems, 2022, 142 (01) : 46 - 54
  • [39] Estimation of sleep quality from ultradian dynamics of heart rate variability in patients with heart failure
    Junya, T
    Hidetsugu, A
    Tsugiyoshi, Y
    Yoshitaka, O
    Hiroshi, U
    Tomoki, K
    Tadakazu, H
    Shinji, I
    Takashi, N
    Hiroshi, I
    JOURNAL OF CARDIAC FAILURE, 2004, 10 (05) : S174 - S174
  • [40] Accuracy and clinical utility of heart rate variability derived from a wearable heart rate monitor in patients undergoing major abdominal surgery
    James Yang
    Erez Ben-Menachem
    Journal of Clinical Monitoring and Computing, 2024, 38 : 433 - 443