Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection

被引:0
|
作者
Juha K. A. Rinne
Seyedsadra Miri
Niku Oksala
Antti Vehkaoja
Jyrki Kössi
机构
[1] Päijät-Häme Central Hospital,Department of Surgery
[2] Tampere University,Finnish Cardiovascular Research Center
[3] Tampere University, Tampere
[4] Tampere University,Faculty of Medicine and Health Technology
[5] Tampere University Hospital,Vascular Centre
[6] PulseOn Ltd,undefined
关键词
Photoplethysmography; PPG; Holter monitor; Heart rate variability; Postoperative recovery; Inter-beat-intervals; RR intervals;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the accuracy of heart rate variability (HRV) parameters obtained with a wrist-worn photoplethysmography (PPG) monitor in patients recovering from minimally invasive colon resection to investigate whether PPG has potential in postoperative patient monitoring. 31 patients were monitored for three days or until discharge or reoperation using a wrist-worn PPG monitor (PulseOn, Finland) with a Holter monitor (Faros 360, Bittium Biosignals, Finland) as a reference measurement device. Beat-to-beat intervals (BBI) and HRV information collected by PPG were compared with RR intervals (RRI) and HRV obtained from the ECG reference after removing artefacts and ectopic beats. The beat-to-beat mean error (ME) and mean absolute error (MAE) of good quality heartbeat intervals obtained by wrist PPG were estimated as − 1.34 ms and 10.4 ms respectively. A significant variation in the accuracy of the HRV parameters was found. In the time domain, SDNN (9.11%), TRI (11.4%) and TINN (11.1%) were estimated with low relative MAE, while RMSSD (34.3%), pNN50 (139%) and NN50 (188%) had higher errors. The logarithmic parameters in the frequency domain (VLF Log, LF Log and HF Log) exhibited the lowest relative error, and for non-linear parameters, SD2 (7.5%), DFA α1 (8.25%) and DFA α2 (4.71%) were calculated much more accurately than SD1 (34.3%). The wrist PPG shows some potential for use in a clinical setting. The accuracy of several HRV parameters analyzed post hoc was found sufficient to be used in further studies concerning postoperative recovery of patients undergoing laparoscopic colon resection, although there were large errors in many common HRV parameters such as RMSSD, pNN50 and NN50, rendering them unusable.
引用
收藏
页码:45 / 53
页数:8
相关论文
共 46 条
  • [1] Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection
    Rinne, Juha K. A.
    Miri, Seyedsadra
    Oksala, Niku
    Vehkaoja, Antti
    Kossi, Jyrki
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (01) : 45 - 53
  • [2] Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
    Biswas, Dwaipayan
    Simoes-Capela, Neide
    Van Hoof, Chris
    Van Helleputte, Nick
    IEEE SENSORS JOURNAL, 2019, 19 (16) : 6560 - 6570
  • [3] Photoplethysmography-based estimation of heart rate recovery using a wrist-worn device
    Sokas, Daivaras
    Petrenas, Andrius
    Daukantas, Saulius
    Rapalis, Andrius
    Marozas, Vaidotas
    2018 16TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC), 2018,
  • [4] Accuracy of Heart-Rate-Recovery Parameters Assessed From a Wrist-Worn Photoplethysmography Monitor (Polar Unite)
    Bretonneau, Quentin
    Peruque-Gayou, Etienne
    Wolfs, Etienne
    Bosquet, Laurent
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2024, 19 (01) : 13 - 18
  • [5] Forecasting of heart rate variability using wrist-worn heart rate monitor based on Hidden Markov Model
    Yun, Sanghun
    Son, Chang-Sik
    Lee, Sang-Ho
    Kang, Won-Seok
    2018 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2018, : 408 - 409
  • [6] The impact of healthy pregnancy on features of heart rate variability and pulse wave morphology derived from wrist-worn photoplethysmography
    M. Bester
    M. J. Almario Escorcia
    P. Fonseca
    M. Mollura
    M. M. van Gilst
    R. Barbieri
    M. Mischi
    J. O. E. H. van Laar
    R. Vullings
    R. Joshi
    Scientific Reports, 13
  • [7] The impact of healthy pregnancy on features of heart rate variability and pulse wave morphology derived from wrist-worn photoplethysmography
    Bester, M.
    Escorcia, M. J. Almario
    Fonseca, P.
    Mollura, M.
    van Gilst, M. M.
    Barbieri, R.
    Mischi, M.
    van Laar, J. O. E. H.
    Vullings, R.
    Joshi, R.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [8] Evaluation of Wrist-Worn Photoplethysmography Trackers with an Electrocardiogram in Patients with Ischemic Heart Disease: A Validation Study
    Nur Syazwani Ibrahim
    Sanjay Rampal
    Wan Ling Lee
    Eu Way Pek
    Anwar Suhaimi
    Cardiovascular Engineering and Technology, 2024, 15 : 12 - 21
  • [9] Evaluation of Wrist-Worn Photoplethysmography Trackers with an Electrocardiogram in Patients with Ischemic Heart Disease: A Validation Study
    Ibrahim, Nur Syazwani
    Rampal, Sanjay
    Lee, Wan Ling
    Pek, Eu Way
    Suhaimi, Anwar
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2024, 15 (01) : 12 - 21
  • [10] Nightbeat: Heart Rate Estimation From a Wrist-Worn Accelerometer During Sleep
    Moebus, Max
    Hauptmann, Lars
    Kopp, Nicolas
    Demirel, Berken Utku
    Braun, Bjorn
    Holz, Christian
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2025, 29 (02) : 870 - 877