Numerical Simulation of a Biventricular Assist Device with Fixed Right Outflow Cannula Banding During Pulmonary Hypertension

被引:0
|
作者
K. Nadeem
B. C. Ng
E. Lim
S. D. Gregory
R. F. Salamonsen
M. C. Stevens
M. Mubin
N. H. Lovell
机构
[1] University of Malaya,Department of Biomedical Engineering
[2] University of Malaya,Asian Cardiac Engineering Laboratory
[3] University of Queensland,School of Medicine
[4] The Prince Charles Hospital,Critical Care Research Group, Innovative Cardiovascular Engineering and Technology Laboratory
[5] Alfred Hospital,Intensive Care Unit
[6] Monash University,Department of Epidemiology and Preventive Medicine
[7] University of Malaya,Deparment of Electrical Engineering
[8] University of South Wales,Graduate School of Biomedical Engineering
来源
Annals of Biomedical Engineering | 2016年 / 44卷
关键词
Ventricular assist device; Heart failure; Pulmonary vascular resistance; Pulmonary artery banding; Systemic vascular resistance;
D O I
暂无
中图分类号
学科分类号
摘要
As a left ventricular assist device is designed to pump against the systemic vascular resistance (SVR), pulmonary congestion may occur when using such device for right ventricular support. The present study evaluates the efficacy of using a fixed right outflow banding in patients receiving biventricular assist device support under various circulatory conditions, including variations in the SVR, pulmonary vascular resistance (PVR), total blood volume (BV), as well as ventricular contractility. Effect of speed variation on the hemodynamics was also evaluated at varying degrees of PVR. Pulmonary congestion was observed at high SVR and BV. A reduction in right ventricular assist device (RVAD) speed was required to restore pulmonary pressures. Meanwhile, at a high PVR, the risk of ventricular suction was prevalent during systemic hypotension due to low SVR and BV. This could be compensated by increasing RVAD speed. Isolated right heart recovery may aggravate pulmonary congestion, as the failing left ventricle cannot accommodate the resultant increase in the right-sided flow. Compared to partial assistance, the sensitivity of the hemodynamics to changes in VAD speed increased during full assistance. In conclusion, our results demonstrated that the introduction of a banding graft with a 5 mm diameter guaranteed sufficient reserve of the pump speed spectrum for the regulation of acceptable hemodynamics over different clinical scenarios, except under critical conditions where drug administration or volume management is required.
引用
收藏
页码:1008 / 1018
页数:10
相关论文
共 50 条
  • [31] Noninvasive Assessment of Right Ventricular Function in Patients with Pulmonary Arterial Hypertension and Left Ventricular Assist Device
    Ramani, Gautam
    Chen, Wengen
    Patel, Sonika
    Judy, Jean
    Ton, Van-Khue
    CURRENT CARDIOLOGY REPORTS, 2019, 21 (08)
  • [32] Assessing the calf pulmonary function during a long-term biventricular assist device study with a centrifugal blood pump
    Nonaka, K
    Linneweber, J
    Ichikawa, S
    Kawahito, S
    Motomura, T
    Ishitoya, H
    Oestmann, D
    Glueck, J
    Nosé, Y
    ARTIFICIAL ORGANS, 2002, 26 (11) : 924 - 926
  • [33] Pulmonary Bleeding During Right Ventricular Support After Left Ventricular Assist Device Implantation
    Welp, Henryk
    Sindermann, Juegen R.
    Deschka, Heinz
    Martens, Sven
    Scherer, Mirela
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (03) : 627 - 631
  • [34] High pulmonary vascular resistance in addition to low right ventricular stroke work index effectively predicts biventricular assist device requirement
    Imamura, Teruhiko
    Kinugawa, Koichiro
    Kinoshita, Osamu
    Nawata, Kan
    Ono, Minoru
    JOURNAL OF ARTIFICIAL ORGANS, 2016, 19 (01) : 44 - 53
  • [35] High pulmonary vascular resistance in addition to low right ventricular stroke work index effectively predicts biventricular assist device requirement
    Teruhiko Imamura
    Koichiro Kinugawa
    Osamu Kinoshita
    Kan Nawata
    Minoru Ono
    Journal of Artificial Organs, 2016, 19 : 44 - 53
  • [36] Hemodynamic effects of pulsatile frequency of right ventricular assist device (RVAD) on pulmonary perfusion: a simulation study
    Meng, Fan
    Zhu, Yuanfei
    Yang, Ming
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (12) : 3875 - 3885
  • [37] Monitoring pulmonary pressures during long-term continuous-flow left ventricular assist device and fixed pulmonary hypertension: redefining alleged pathophysiological mechanisms?
    De Bakker, Chantal C.
    Veenis, Jesse F.
    Manintveld, Olivier C.
    Constantinescu, Alina A.
    Caliskan, K.
    den Uil, Corstiaan A.
    Brugts, Jasper J.
    ESC HEART FAILURE, 2020, 7 (02): : 702 - 704
  • [38] The use of a durable right ventricular assist device for isolated right ventricular failure due to combined pre- and postcapillary pulmonary hypertension
    Vullaganti, Sirish
    Tibrewala, Anjan
    Rich, Jonathan D.
    Duc T Pham
    Rich, Stuart
    PULMONARY CIRCULATION, 2019, 9 (02)
  • [39] Biventricular failure with low pulmonary vascular resistance was managed by left ventricular assist device alone without right-sided mechanical support
    Teruhiko Imamura
    Koichiro Kinugawa
    Daisuke Nitta
    Masaru Hatano
    Osamu Kinoshita
    Kan Nawata
    Minoru Ono
    Journal of Artificial Organs, 2015, 18 : 272 - 275
  • [40] Biventricular failure with low pulmonary vascular resistance was managed by left ventricular assist device alone without right-sided mechanical support
    Imamura, Teruhiko
    Kinugawa, Koichiro
    Nitta, Daisuke
    Hatano, Masaru
    Kinoshita, Osamu
    Nawata, Kan
    Ono, Minoru
    JOURNAL OF ARTIFICIAL ORGANS, 2015, 18 (03) : 272 - 275