Numerical Simulation of a Biventricular Assist Device with Fixed Right Outflow Cannula Banding During Pulmonary Hypertension

被引:0
|
作者
K. Nadeem
B. C. Ng
E. Lim
S. D. Gregory
R. F. Salamonsen
M. C. Stevens
M. Mubin
N. H. Lovell
机构
[1] University of Malaya,Department of Biomedical Engineering
[2] University of Malaya,Asian Cardiac Engineering Laboratory
[3] University of Queensland,School of Medicine
[4] The Prince Charles Hospital,Critical Care Research Group, Innovative Cardiovascular Engineering and Technology Laboratory
[5] Alfred Hospital,Intensive Care Unit
[6] Monash University,Department of Epidemiology and Preventive Medicine
[7] University of Malaya,Deparment of Electrical Engineering
[8] University of South Wales,Graduate School of Biomedical Engineering
来源
Annals of Biomedical Engineering | 2016年 / 44卷
关键词
Ventricular assist device; Heart failure; Pulmonary vascular resistance; Pulmonary artery banding; Systemic vascular resistance;
D O I
暂无
中图分类号
学科分类号
摘要
As a left ventricular assist device is designed to pump against the systemic vascular resistance (SVR), pulmonary congestion may occur when using such device for right ventricular support. The present study evaluates the efficacy of using a fixed right outflow banding in patients receiving biventricular assist device support under various circulatory conditions, including variations in the SVR, pulmonary vascular resistance (PVR), total blood volume (BV), as well as ventricular contractility. Effect of speed variation on the hemodynamics was also evaluated at varying degrees of PVR. Pulmonary congestion was observed at high SVR and BV. A reduction in right ventricular assist device (RVAD) speed was required to restore pulmonary pressures. Meanwhile, at a high PVR, the risk of ventricular suction was prevalent during systemic hypotension due to low SVR and BV. This could be compensated by increasing RVAD speed. Isolated right heart recovery may aggravate pulmonary congestion, as the failing left ventricle cannot accommodate the resultant increase in the right-sided flow. Compared to partial assistance, the sensitivity of the hemodynamics to changes in VAD speed increased during full assistance. In conclusion, our results demonstrated that the introduction of a banding graft with a 5 mm diameter guaranteed sufficient reserve of the pump speed spectrum for the regulation of acceptable hemodynamics over different clinical scenarios, except under critical conditions where drug administration or volume management is required.
引用
收藏
页码:1008 / 1018
页数:10
相关论文
共 50 条
  • [21] Novel Combination Predictors of Biventricular Assist Device Requirement: Pulmonary Vascular Resistance and Right Ventricular Stroke Work Index
    Imamura, Teruhiko
    Kinugawa, Koichiro
    Nitta, Daisuke
    Hatano, Masaru
    Kinoshita, Osamu
    Nawata, Kan
    Ono, Minoru
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (10) : S190 - S190
  • [22] Effect of Left-Right Heart During Biventricular Assist Device Support by Speed Synchronization: A Computer Study
    Naiyanetr, Phornphop
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 617 - 622
  • [23] Normalization of fixed pulmonary hypertension in severe heart failure patients with placement of left ventricular assist device
    Zolty, Ronald
    Shakar, Simon
    Wolfel, Eugene
    Cannon, Anne
    Cleveland, Joseph, Jr.
    Lowes, Brian D.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 58A - 58A
  • [24] Normalization of Fixed Pulmonary Hypertension in Severe Heart Failure Patients with Placement of Left Ventricular Assist Device
    Zolty, Z.
    Vittorio, T.
    Lowes, B.
    Shakar, S.
    Brieke, A.
    Cannon, A.
    Cleveland, J.
    D'Alessandro, D.
    Goldstein, D.
    Maybaum, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S265 - S265
  • [25] First Implantation of a Heartware Right Ventricular Assist Device for Right Ventricular Failure Caused by Severe Idiopathic Pulmonary Hypertension
    Vierecke, J.
    Schweiger, M.
    Dandel, M.
    Stepanenko, A.
    Dranishnikov, N.
    Jurmann, B.
    Potapov, E.
    Hennig, E.
    Hetzer, R.
    Krabatsch, T.
    TRANSPLANTATION, 2012, 94 (10) : 944 - 944
  • [26] The impact of right ventricular hemodynamics on the performance of a left ventricular assist device in a numerical simulation model
    Thut, Titus L. Z.
    Petrou, Anastasios
    Meboldt, Mirko
    Daners, Marianne Schmid
    Wilhelm, Markus J.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (05): : 503 - 510
  • [27] Sophisticated Hydrodynamic Simulation of Pulmonary Circulation for the Preclinical Examination of Right Heart Circulatory Assist Device
    Tsuboko, Yusuke
    Shiraishi, Yasuyuki
    Yamada, Akihiro
    Iwasaki, Kiyotaka
    Umezu, Mitsuo
    Yambe, Tomoyuki
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 717 - 720
  • [28] Intersection of Pulmonary Hypertension and Right Ventricular Dysfunction in Patients on Left Ventricular Assist Device Support Is There a Role for Pulmonary Vasodilators?
    Sparrow, Christopher T.
    LaRue, Shane J.
    Schilling, Joel D.
    CIRCULATION-HEART FAILURE, 2018, 11 (01) : e004255
  • [29] Noninvasive Assessment of Right Ventricular Function in Patients with Pulmonary Arterial Hypertension and Left Ventricular Assist Device
    Gautam Ramani
    Wengen Chen
    Sonika Patel
    Jean Judy
    Van-Khue Ton
    Current Cardiology Reports, 2019, 21
  • [30] Right ventricular assist device use in ventricular failure due to pulmonary arterial hypertension: Lessons learned
    Rosenzweig, Erika B.
    Chicotka, Scott
    Bacchetta, Matthew
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (10): : 1272 - 1274