High-frequency measurement of concentration in an isothermal methane–air gas mixture using spontaneous Raman spectroscopy

被引:0
|
作者
Jocelino Rodrigues
Lee Weller
Francesca De Domenico
Simone Hochgreb
机构
[1] University of Cambridge,Department of Engineering
[2] Delft University of Technology,Aerospace Engineering
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A high-frequency (1.5 kHz) spontaneous Raman spectroscopy measurement technique is developed and applied to measure external fluctuations generated in the local concentration of an isothermal binary gas mixture of methane and air. Raman excitation is provided by a high-frequency laser at 527 nm in dual-pulsed mode. The Stokes Raman signal is collected using an EMCCD camera coupled to a high-frequency intensifier as a shutter. The emitted signal is collected over the 596–627 nm wavelength range, which allows for the simultaneous tracking of methane and nitrogen Stokes Q-branch mode signals. Calibration curves are initially obtained for each species (CH4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\text{CH}}_{4}$$\end{document} and N2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{N}}_{2}$$\end{document}) based on steady-state concentrations, and further corrected during use to detect local unsteady mixture fluctuations at gas pulsation frequencies up to 250 Hz. The main novelty is the demonstration of Raman spectroscopy for the simultaneous multispecies measurement of unsteady concentrations of gas-phase methane and air mixtures using a laser beam with a high-repetition rate, low energy per pulse, combined with a high-frequency intensifier and a single camera.
引用
收藏
相关论文
共 50 条
  • [31] Methane conversion using a high-frequency pulsed plasma: Important factors
    Yao, SL
    Nakayama, A
    Suzuki, E
    AICHE JOURNAL, 2001, 47 (02) : 413 - 418
  • [32] Oxidation of activated carbon and methane using a high-frequency pulsed plasma
    Yao, SL
    Suzuki, E
    Nakayama, A
    JOURNAL OF HAZARDOUS MATERIALS, 2001, 83 (03) : 237 - 242
  • [33] High-frequency jet ventilation using a helium-oxygen mixture
    Tobias, JD
    Grueber, RE
    PAEDIATRIC ANAESTHESIA, 1999, 9 (05): : 451 - 455
  • [34] Methane conversion using a high-frequency pulsed plasma: Discharge features
    Yao, SL
    Nakayama, A
    Suzuki, E
    AICHE JOURNAL, 2001, 47 (02) : 419 - 426
  • [35] Analysis on measurement of hydrogen concentration in air mixture using 3 omega method
    Oh, Dong-Wook
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2022, 19 (01) : 88 - 93
  • [36] High finesse Fabry-Perot filter for the measurement of methane gas by using multiline absorption spectroscopy
    Ye, Jiansen
    OPTICAL ENGINEERING, 2014, 53 (02)
  • [37] Concentration determination of a binary mixture of air and carbon disulfide gas using optoacoustics
    Cheyne, SA
    McDermott, WC
    Rannals, MD
    Vaughan, JE
    ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2004, 5 (02): : 7 - 12
  • [38] CONCENTRATION OF OH RADICALS IN A GAS-STREAM SUBJECTED TO HIGH-FREQUENCY DISCHARGE
    BARANOV, GA
    ZINCHENKO, AK
    LEDNEV, MG
    PODTYKAN, FP
    HIGH ENERGY CHEMISTRY, 1988, 22 (06) : 444 - 448
  • [39] High-frequency ESR Measurement at 315 GHz Using a Microcantilever
    E. Ohmichi
    N. Mizuno
    S. Hirano
    H. Ohta
    Journal of Low Temperature Physics, 2010, 159 : 276 - 279
  • [40] MEASUREMENT OF THE DEPTH OF KERATOTOMY INCISIONS USING HIGH-FREQUENCY ULTRASOUND
    BELMONT, SC
    MULLER, JW
    SILVERMAN, RH
    REINSTEIN, DZ
    ASLANIDES, IM
    COLEMAN, DJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2017 - 2017