Interstitial brachytherapy for recurrent breast cancer using a high dose rate Ir-192 remote afterloading system: A report of two cases

被引:0
|
作者
Yoden E. [1 ,3 ]
Hiratsuka J. [1 ]
Imajo Y. [1 ]
Yamamoto S. [2 ]
Kurebayashi J. [2 ]
Shimozurna K. [2 ]
Sonoo H. [2 ]
机构
[1] Departments of Radiation Oncology, Kawasaki Medical School
[2] Departments of Breast and Thyroid Surgery, Kawasaki Medical School
[3] Department of Radiology, Kobe Universily, School of Medicine, Chuo-ku, Kobe, Hyogo 650-0017
关键词
Breast cancer; Interstitial brachytherapy; Radiotherapy; Recurrence;
D O I
10.1007/BF02967469
中图分类号
学科分类号
摘要
We employed interstitial brachytherapy using a high dose rate Ir-192 remote aflerloading unit in two breast cancer patients with Iocoregional recurrence. In the first case, skin metastasis was treated, with favorable control of the infield tumor but subsequent persistent sequelae and multiple outfield metastases. This experience caused us to be cautious when choosing brachytherapy for the second case, in whom a solitary metastasis to an axillary lymph node was successfully treated. Although this method is still investigational, it may play a critical role in the treatment of Iocoregional recurrence resistant to other treatment modalities.
引用
收藏
页码:252 / 255
页数:3
相关论文
共 50 条
  • [11] CONVERSION FROM CS-137 TO IR-192 FOR HIGH-DOSE RATE REMOTE AFTERLOADING - PRACTICAL CONSIDERATIONS
    BELLOTTI, JE
    KAGAN, AR
    OLCH, A
    WOLLIN, M
    MEDICAL PHYSICS, 1992, 19 (02) : 377 - 383
  • [12] HIGH-DOSE AFTERLOADING TREATMENT WITH IR-192 IN HEAD AND NECK-CANCER
    VONSCHEEL, J
    KOCH, K
    LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1987, 66 (06): : 329 - 331
  • [13] Calibration of Ir-192 high dose rate brachytherapy source using different calibration procedures
    Bondel, Shwetha
    Ravikumar, Manickham
    Supe, Sanjay Sudhakar
    Reddy, Buchuppudi Rekha
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (03) : 151 - 156
  • [14] INTERSTITIAL HIGH-DOSE-RATE BRACHYTHERAPY WITH IR-192 IN PATIENTS WITH ORAL SQUAMOUS-CELL CARCINOMA
    FRIEDRICH, RE
    KRULL, A
    HELLNER, D
    SCHWARZ, R
    HEYER, D
    PLAMBECK, K
    SCHMELZLE, R
    JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY, 1995, 23 (04): : 238 - 242
  • [15] Study of the dosimetric differences between Ir-192 and Co-60 sources of high dose rate brachytherapy for breast interstitial implant
    Sinnatamby, Mourougan
    Nagarajan, Vivekanandan
    Sathyanarayana, Reddy Kanipakam
    Karunanidhi, Gunaseelan
    Singhavajala, Vivekanandam
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (05) : 453 - 459
  • [16] Interstitial brachytherapy for lip carcinomas: Comparison between Ir-192 low-dose-rate and high-dose-rate treatment
    Cuenin, M.
    Salleron, J.
    Peiffert, D.
    Meknaci, E.
    Gallet, P.
    Abushama, Y.
    Py, J. -F
    Renard, S.
    CANCER RADIOTHERAPIE, 2024, 28 (02): : 145 - 151
  • [17] Reference air kerma rate calibration system for high dose rate Ir-192 brachytherapy sources in Taiwan
    Chu, Wei-Han
    Yuan, Ming-Chen
    Lee, Jeng-Hung
    Lin, Yi-Chun
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 361 - 364
  • [18] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemah
    Saidi, Pooneh
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (05) : 324 - 329
  • [19] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [20] Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization
    Gay, H. A.
    Allison, R. R.
    Downie, G. H.
    Mota, H. C.
    Austerlitz, C.
    Jenkins, T.
    Sibata, C. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 2987 - 2999