Accuracy of intraoperative estimation of femoral stem anteversion in cementless total hip arthroplasty by using a digital protractor and a spirit level

被引:0
|
作者
Anuwat Pongkunakorn
Nawakun Phetpangnga
Narawit Kananai
机构
[1] Lampang Hospital and Medical Educational Center,Department of Orthopaedic Surgery
关键词
Femoral stem anteversion; cementless total hip arthroplasty; digital protractor; spirit level;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Total hip arthroplasty using a monobloc cementless femoral stem for patients with childhood Perthes' disease
    Lee, K. H.
    Jo, W-L.
    Ha, Y. C.
    Lee, Y. K.
    Goodman, S. B.
    Koo, K. H.
    BONE & JOINT JOURNAL, 2017, 99B (04): : 440 - 444
  • [32] Intraoperative fluoroscopic confirmation of the knee improves the accuracy of stem anteversion in total hip arthroplasty with direct anterior approach using traction table
    Miura, Michiaki
    Suzuki, Takeshi
    Wako, Yasushi
    Hoshi, Hiroko
    Fukawa, Taisuke
    Itadera, Eichi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4217 - 4223
  • [33] Optimal Level of Femoral Neck for Predicting Postoperative Stem Anteversion in Total Hip Arthroplasty for Crowe Type I Dysplastic Hip
    Yu, Degang
    Zhai, Zanjing
    Zhang, Jingwei
    Zhu, Zhenan
    Li, Huiwu
    Yan, Mengning
    Mao, Yuanqing
    ORTHOPAEDIC SURGERY, 2020, 12 (02) : 480 - 487
  • [34] Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(R))
    Tootsi, Kaspar
    Lees, Loviisa
    Geiko, Boris
    Martson, Aare
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 21 (01)
  • [35] Lower Rates of Femoral Fracture and Subsidence with a Morphometric Stem in Cementless Total Hip Arthroplasty
    Coden, Gloria
    Naylor, Brandon
    Hameed, Daniel
    Mont, Michael A.
    Hepinstall, Matthew S.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2023, 42
  • [36] Validity of the intra-operative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach
    Lee, Y. K.
    Kim, J. W.
    Kim, T. Y.
    Ha, Y. C.
    Koo, K. H.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (03) : 341 - 346
  • [37] How to Estimate Femoral Stem Anteversion During Direct Anterior Approach Total Hip Arthroplasty
    Gold, Peter A.
    McCarthy, Thomas F.
    Borukhov, Ilya
    Danoff, Jonathan
    ARTHROPLASTY TODAY, 2024, 26
  • [38] Error of intraoperative measurement of stem anteversion is decreased by measuring in neutral hip position during total hip arthroplasty
    Sonoda, Kazuhiko
    Kubo, Yusuke
    Komiyama, Keisuke
    Nakamura, Tetsuro
    Hara, Toshihiko
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (05) : 1235 - 1241
  • [39] Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty
    Zheng, Wei
    Liu, Xuefeng
    Mei, Runhong
    Deng, Gaorong
    Li, Zhipeng
    Lin, Rongji
    Xiong, Shui
    Wu, Binghua
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [40] Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty
    Wei Zheng
    Xuefeng Liu
    Runhong Mei
    Gaorong Deng
    Zhipeng Li
    Rongji Lin
    Shui Xiong
    Binghua Wu
    BioMedical Engineering OnLine, 22