Error of intraoperative measurement of stem anteversion is decreased by measuring in neutral hip position during total hip arthroplasty

被引:0
|
作者
Sonoda, Kazuhiko [1 ]
Kubo, Yusuke [1 ]
Komiyama, Keisuke [1 ]
Nakamura, Tetsuro [2 ]
Hara, Toshihiko [1 ]
机构
[1] Iizuka Hosp, Dept Orthopaed Surg, 3-83 Yoshiomachi, Iizuka 8208505, Japan
[2] Fukuoka Mirai Hosp, Dept Orthopaed Surg, 3-5-1 Higashi Ku, Fukuoka 8130017, Japan
关键词
Stem anteversion; Combined anteversion; Intraoperative evaluation; Total hip arthroplasty; Computed tomography; ACETABULAR COMPONENT; DISLOCATION; PLACEMENT; ACCURACY; MOTION; RANGE;
D O I
10.1016/j.jos.2023.08.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Intraoperative stem anteversion, which is the angle between the lower leg axis and the trial-stem axis with hip flexion and adduction, is generally evaluated by the surgeon's visual estimation during total hip arthroplasty (THA). However, the conventional approach can be influenced by knee osteoarthritis or uncertain surgeon's observation point. Therefore, we developed a new method for measuring the stem anteversion angle in the neutral hip position using an original rod attached to the trial-stem perpendicular to the long axis and parallel to the stem neck. This study aimed to assess the accuracy of our method in comparison with the conventional method of measuring intraoperative stem anteversion angle. Methods: We measured the intraoperative stem anteversion angle in consecutive 106 hips of 106 patients who underwent cementless primary THA with a tapered wedge stem. Absolute error in the stem anteversion angle was expressed as the difference between intraoperative (common vs. neutral hip positions) and postoperative computed tomography measurements, i.e., true stem anteversion. Additionally, we investigated the factors affecting these errors. Results: The absolute error of measurement was significantly smaller in the neutral hip position than in the common position (3.0 degrees +/- 2.5 degrees vs. 8.0 degrees +/- 3.9 degrees; p < 0.0001). The factor associated with the error was advanced knee osteoarthritis in the common position, whereas it was not statistically significant in the neutral hip position. Conclusions: This study suggests that the error in the intraoperative measurement of stem anteversion is decreased by measuring in the neutral hip position during THA. (c) 2023 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1235 / 1241
页数:7
相关论文
共 50 条
  • [1] A Novel Device for Intraoperative Measurement of Stem Anteversion Angle in Total Hip Arthroplasty
    Iwakiri, Kentaro
    Ohta, Yoichi
    Ueno, Shuhei
    Minoda, Yukihide
    Kobayashi, Akio
    Nakamura, Hiroaki
    ARTHROPLASTY TODAY, 2024, 28
  • [2] Surgeon Error in Performing Intraoperative Estimation of Stem Anteversion in Cementless Total Hip Arthroplasty
    Hirata, Masanobu
    Nakashima, Yasuharu
    Ohishi, Masanobu
    Hamai, Satoshi
    Hara, Daisuke
    Iwamoto, Yukihide
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1648 - 1653
  • [3] A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty
    Ryo Mitsutake
    Hiromasa Tanino
    Yasuhiro Nishida
    Masaru Higa
    Hiroshi Ito
    BMC Musculoskeletal Disorders, 21
  • [4] A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty
    Mitsutake, Ryo
    Tanino, Hiromasa
    Nishida, Yasuhiro
    Higa, Masaru
    Ito, Hiroshi
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [5] A Useful Anatomical Reference Guide for Stem Anteversion during Total Hip Arthroplasty in the Dysplastic Hip
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    JOURNAL OF ARTHROPLASTY, 2015, 30 (08): : 1393 - 1396
  • [6] Intraoperative measurement of limb lengthening during total hip arthroplasty
    Dimitrios Vasileiou Papadopoulos
    Panagiotis Koulouvaris
    Georgios Charalambos Aggelidakis
    Andreas Georgios Tsantes
    Marios Georgios Lykissas
    Alexandros Mavrodontidis
    Indian Journal of Orthopaedics, 2017, 51 : 162 - 167
  • [7] Intraoperative measurement of limb lengthening during total hip arthroplasty
    Papadopoulos, Dimitrios Vasileiou
    Koulouvaris, Panagiotis
    Aggelidakis, Georgios Charalambos
    Tsantes, Andreas Georgios
    Lykissas, Marios Georgios
    Mavrodontidis, Alexandros
    INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (02) : 162 - 167
  • [8] Even the Intraoperative Knowledge of Femoral Stem Anteversion Cannot Prevent Impingement in Total Hip Arthroplasty
    Weber, Markus
    Woerner, Michael L.
    Sendtner, Ernst
    Voellner, Florian
    Grifka, Joachim
    Renkawitz, Tobias F.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (11): : 2514 - 2519
  • [9] Digital protractor as an intraoperative guide to cup anteversion in total hip arthroplasty
    Yi, Ning
    Yuan, Hang
    Xu, Nanwei
    Liu, Ruiping
    Wang, Yuji
    Zhuang, Chao
    BMC SURGERY, 2024, 24 (01)
  • [10] Digital protractor as an intraoperative guide to cup anteversion in total hip arthroplasty
    Ning Yi
    Hang Yuan
    Nanwei Xu
    Ruiping Liu
    Yuji Wang
    Chao Zhuang
    BMC Surgery, 24