Error of intraoperative measurement of stem anteversion is decreased by measuring in neutral hip position during total hip arthroplasty

被引:0
|
作者
Sonoda, Kazuhiko [1 ]
Kubo, Yusuke [1 ]
Komiyama, Keisuke [1 ]
Nakamura, Tetsuro [2 ]
Hara, Toshihiko [1 ]
机构
[1] Iizuka Hosp, Dept Orthopaed Surg, 3-83 Yoshiomachi, Iizuka 8208505, Japan
[2] Fukuoka Mirai Hosp, Dept Orthopaed Surg, 3-5-1 Higashi Ku, Fukuoka 8130017, Japan
关键词
Stem anteversion; Combined anteversion; Intraoperative evaluation; Total hip arthroplasty; Computed tomography; ACETABULAR COMPONENT; DISLOCATION; PLACEMENT; ACCURACY; MOTION; RANGE;
D O I
10.1016/j.jos.2023.08.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Intraoperative stem anteversion, which is the angle between the lower leg axis and the trial-stem axis with hip flexion and adduction, is generally evaluated by the surgeon's visual estimation during total hip arthroplasty (THA). However, the conventional approach can be influenced by knee osteoarthritis or uncertain surgeon's observation point. Therefore, we developed a new method for measuring the stem anteversion angle in the neutral hip position using an original rod attached to the trial-stem perpendicular to the long axis and parallel to the stem neck. This study aimed to assess the accuracy of our method in comparison with the conventional method of measuring intraoperative stem anteversion angle. Methods: We measured the intraoperative stem anteversion angle in consecutive 106 hips of 106 patients who underwent cementless primary THA with a tapered wedge stem. Absolute error in the stem anteversion angle was expressed as the difference between intraoperative (common vs. neutral hip positions) and postoperative computed tomography measurements, i.e., true stem anteversion. Additionally, we investigated the factors affecting these errors. Results: The absolute error of measurement was significantly smaller in the neutral hip position than in the common position (3.0 degrees +/- 2.5 degrees vs. 8.0 degrees +/- 3.9 degrees; p < 0.0001). The factor associated with the error was advanced knee osteoarthritis in the common position, whereas it was not statistically significant in the neutral hip position. Conclusions: This study suggests that the error in the intraoperative measurement of stem anteversion is decreased by measuring in the neutral hip position during THA. (c) 2023 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1235 / 1241
页数:7
相关论文
共 50 条
  • [41] Intraoperative cerebral arterial embolization during total hip arthroplasty
    Edmonds, CR
    Barbut, D
    Hager, D
    Lo, Y
    Sharrock, NE
    ANESTHESIOLOGY, 1997, 87 (03) : A150 - A150
  • [42] Intraoperative fractures of the acetabulum during primary total hip arthroplasty
    Haidukewych, George J.
    Jacofsky, David J.
    Hanssen, Arlen D.
    Lewallen, David G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (09): : 1952 - 1956
  • [43] Management of Intraoperative Acetabular Fractures During Total Hip Arthroplasty
    Stauffer, Taylor P.
    Purcell, Kevin F.
    Pean, Christian
    DeBaun, Malcolm
    Bolognesi, Michael
    Ryan, Sean
    Chun, Danielle
    Seyler, Thorsten
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2024, 55 (01) : 9 - 17
  • [44] Neurophysiologic intraoperative monitoring during revision total hip arthroplasty
    Brown, DM
    McGinnis, WC
    Mesghali, H
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A : 56 - 61
  • [45] Intraoperative cerebral arterial embolization during total hip arthroplasty
    Edmonds, CR
    Barbut, D
    Hager, D
    Sharrock, NE
    ANESTHESIOLOGY, 2000, 93 (02) : 315 - 318
  • [46] Ellipse method for measuring Liaw’s anteversion of the acetabular component after total hip arthroplasty
    Kuei-Lin Yeh
    Tai-Yin Wu
    Hsuan-Hsiao Ma
    Sheng-Mou Hou
    Chen-Kun Liaw
    BMC Musculoskeletal Disorders, 21
  • [47] Use of the G-guide for Measuring Stem Antetorsion During Total Hip Arthroplasty
    Fujihara, Yuki
    Fukunishi, Shigeo
    Fukui, Tomokazu
    Nishio, Shoji
    Okahisa, Shohei
    Takeda, Yu
    Kurosaka, Kenji
    Yoshiya, Shinichi
    ORTHOPEDICS, 2016, 39 (02) : E271 - E275
  • [48] Combined anteversion technique in total hip arthroplasty for Crowe IV developmental dysplasia of the hip
    Zhu, Biao
    Su, Changzheng
    He, Yeteng
    Chai, Xingyu
    Li, Zhen
    Hou, Zhenyang
    Lou, Tengteng
    Yan, Xinfeng
    HIP INTERNATIONAL, 2017, 27 (06) : 589 - 594
  • [49] Accuracy of femoral component anteversion in robotic total hip arthroplasty
    Sugano, Nobuhiko
    Maeda, Yuki
    Fuji, Haruka
    Tamura, Kazunori
    Nakamura, Nobuo
    Takashima, Kazuma
    Uemura, Keisuke
    Hamada, Hidetoshi
    BONE & JOINT JOURNAL, 2024, 106B (03): : 104 - 109
  • [50] A METHOD OF INTRAOPERATIVE LIMB LENGTH MEASUREMENT IN TOTAL HIP-ARTHROPLASTY
    WOOLSON, ST
    HARRIS, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1985, (194) : 207 - 210