Operative treatment of distal radial fractures with locking plate system—a prospective study

被引:0
|
作者
Kenny Kwan
Tak Wing Lau
Frankie Leung
机构
[1] Queen Mary Hospital,Department of Orthopaedics and Traumatology
[2] University of Hong Kong,Department of Orthopaedics and Traumatology
来源
关键词
Scaphoid Fracture; Flexor Carpus Radialis; Tension Band Wiring; Distal Radial Fracture; Radial Inclination;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to determine the results of operative treatment of distal radial fractures with a 2.4-mm locking plate system in a single tertiary teaching hospital. Seventy-five patients were recruited into the study between May 2004 and November 2006. There were 41 males and 34 females, with a mean age of 51. Seventy-five percent of patients had AO type C fractures. All patients were allowed free active mobilisation of the wrist joint immediately after surgery. They were followed up at two weeks, three months, six months, one year and two years. Assessments of pain, motion, grip strength, and standard radiographs were performed. The Gartland and Werley functional scores, the modified Green and O’Brien score, and the disabilities of the arm, shoulder and hand (DASH) scores were recorded. The radiographic results at the final follow-up showed a mean of 18° of radial inclination, 5° of volar tilt, 1.3-mm radial shortening, and no articular incongruity. Twenty-nine percent of patients showed grade 1 osteoarthritic changes and 6% had grade 2 changes in their final follow-up radiographs. An excellent or good result was obtained in 98% and 96% of patients according to the Gartland and Werley, and modified Green and O’Brien scores, respectively. The mean DASH score was 11.6, indicating a high level of patient satisfaction. Internal fixation of distal radial fractures with a 2.4-mm locking plate system provided a stable fixation with good clinical outcomes and patient satisfaction.
引用
收藏
页码:389 / 394
页数:5
相关论文
共 50 条
  • [41] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Yu Zhou
    Yanbiao Wang
    Lifeng Liu
    Zhenyu Zhou
    Xuecheng Cao
    International Orthopaedics, 2015, 39 : 2227 - 2237
  • [42] Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
    Arora, R
    Lutz, M
    Fritz, D
    Zimmermann, R
    Oberladstätter, J
    Gabl, M
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (06) : 399 - 404
  • [43] Unstable Distal Radial Fractures Treated with External Fixation, a Radial Column Plate, or a Volar Plate A Prospective Randomized Trial
    Wei, David H.
    Raizman, Noah M.
    Bottino, Clement J.
    Jobin, Charles M.
    Strauch, Robert J.
    Rosenwasser, Melvin P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07): : 1568 - 1577
  • [44] Displaced medial clavicle fractures: operative treatment with locking compression plate fixation
    Herman Frima
    Roderick M. Houwert
    Christoph Sommer
    European Journal of Trauma and Emergency Surgery, 2020, 46 : 207 - 213
  • [45] Displaced medial clavicle fractures; operative treatment with locking compression plate fixation
    Frima, H.
    Houwert, R. M.
    Sommer, C.
    BRITISH JOURNAL OF SURGERY, 2018, 105 : 10 - 10
  • [46] Displaced medial clavicle fractures: operative treatment with locking compression plate fixation
    Frima, Herman
    Houwert, Roderick M.
    Sommer, Christoph
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (01) : 207 - 213
  • [47] Volar locking plate vs epibloc system for distal radius fractures in the elderly
    Solarino, Giuseppe
    Vicenti, Giovanni
    Abate, Antonella
    Carrozzo, Massimiliano
    Picca, Girolamo
    Colella, Antonio
    Moretti, Biagio
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S84 - S90
  • [48] Prospective Study of Distal Radial Fractures Treated with an Intramedullary Nail
    Nishiwaki, Masao
    Tazaki, Kenichi
    Shimizu, Hidenori
    Ilyas, Asif M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15): : 1436 - 1441
  • [49] Plate fixation with locking screw for distal fractures of the radius
    Cognet, J. -M.
    Geanah, A.
    Marsal, C.
    Kadoch, V.
    Gouzou, S.
    Simon, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (07): : 663 - 672
  • [50] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63