Operative treatment of distal radial fractures with locking plate system—a prospective study

被引:0
|
作者
Kenny Kwan
Tak Wing Lau
Frankie Leung
机构
[1] Queen Mary Hospital,Department of Orthopaedics and Traumatology
[2] University of Hong Kong,Department of Orthopaedics and Traumatology
来源
关键词
Scaphoid Fracture; Flexor Carpus Radialis; Tension Band Wiring; Distal Radial Fracture; Radial Inclination;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to determine the results of operative treatment of distal radial fractures with a 2.4-mm locking plate system in a single tertiary teaching hospital. Seventy-five patients were recruited into the study between May 2004 and November 2006. There were 41 males and 34 females, with a mean age of 51. Seventy-five percent of patients had AO type C fractures. All patients were allowed free active mobilisation of the wrist joint immediately after surgery. They were followed up at two weeks, three months, six months, one year and two years. Assessments of pain, motion, grip strength, and standard radiographs were performed. The Gartland and Werley functional scores, the modified Green and O’Brien score, and the disabilities of the arm, shoulder and hand (DASH) scores were recorded. The radiographic results at the final follow-up showed a mean of 18° of radial inclination, 5° of volar tilt, 1.3-mm radial shortening, and no articular incongruity. Twenty-nine percent of patients showed grade 1 osteoarthritic changes and 6% had grade 2 changes in their final follow-up radiographs. An excellent or good result was obtained in 98% and 96% of patients according to the Gartland and Werley, and modified Green and O’Brien scores, respectively. The mean DASH score was 11.6, indicating a high level of patient satisfaction. Internal fixation of distal radial fractures with a 2.4-mm locking plate system provided a stable fixation with good clinical outcomes and patient satisfaction.
引用
收藏
页码:389 / 394
页数:5
相关论文
共 50 条
  • [31] Outcomes of distal ulna locking plate in management of unstable distal ulna fractures: a prospective case series
    K. Stock
    S. Benedikt
    T. Kastenberger
    P. Kaiser
    R. Arora
    P. Zelger
    J. D. Pallua
    G. Schmidle
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3137 - 3144
  • [32] Management of distal femoral periprosthetic fractures by distal femoral locking plate: A retrospective study
    Rajiv Thukral
    S. K. S. Marya
    Chandeep Singh
    Indian Journal of Orthopaedics, 2015, 49 : 199 - 207
  • [33] Surgical Treatment of Distal Radial Fractures with External Fixation Versus Volar Locking Plate A Multicenter Randomized Controlled Trial
    Ludvigsen, Trine
    Matre, Kjell
    Gudmundsdottir, Rakel Sif
    Krukhaug, Yngvar
    Dybvik, Eva Hansen
    Fevang, Jonas Meling
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2021, 103 (05): : 405 - 414
  • [34] Treatment of extra-articular and simple articular distal radial fractures with intramedullary nail versus volar locking plate
    Safi, A.
    Hart, R.
    Teknedzjan, B.
    Kozak, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 774 - 779
  • [35] Surgical Treatment of Distal Radial Fractures with a Volar Locking Plate Versus Conventional Percutaneous Methods A Randomized Controlled Trial
    Karantana, Alexia
    Downing, Nicholas D.
    Forward, Daren P.
    Hatton, Mark
    Taylor, Andrew M.
    Scammell, Brigitte E.
    Moran, Chris G.
    Davis, Tim R. C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (19): : 1737 - 1744
  • [36] Cost-effectiveness of volar locking plate versus percutaneous fixation for distal radial fractures
    Karantana, A.
    Davis, T. R. C.
    Scammell, B. E.
    Whynes, D. K.
    BONE & JOINT JOURNAL, 2015, 97B (09): : 1264 - 1270
  • [37] Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures
    Usta, Emirhan
    Akpolat, Ahmet O.
    Kahraman, Ahmet N.
    Kara, Adnan
    Oc, Yunus
    Kilinc, Bekir E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [38] Outcome After Treatment of Distal Fibula Fractures Using One-Third Tubular Plate, Locking Compression Plate or Distal Anatomical Locking Compression Plate
    Jensen, Thomas Giver
    Almadareb, Mostafa Aqeel Khudhair
    Nielsen, Maria Booth
    Hansen, Emil Jesper
    Lindberg-Larsen, Martin
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (03): : 524 - 528
  • [39] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Zhou, Yu
    Wang, Yanbiao
    Liu, Lifeng
    Zhou, Zhenyu
    Cao, Xuecheng
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2227 - 2237
  • [40] Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
    R. Arora
    M. Lutz
    D. Fritz
    R. Zimmermann
    J. Oberladstätter
    M. Gabl
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 399 - 404