Condensed-history Monte Carlo simulation of the dosimetric distribution of electron microbeam

被引:0
|
作者
Yunzhi Ma
Hongyu Zhou
Yizhong Zhuo
机构
[1] Beijing Normal University,The Key Laboratory of Beam Technology and Material Modification of Ministry of Education, and Institute of Low Energy Nuclear Physics
[2] China Institute of Atomic Energy,undefined
来源
关键词
Analog Algorithm; Bystander Effect; Beam Radius; Average Event Size; Track Structure;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the dose distributions of an electron microbeam and to help optimization of its design, the condensed-history (CH) Monte Carlo simulation algorithm implemented in the Geant4 toolkit was selected as an alternative to the conventionally used analog algorithm. Compared to the analog algorithm, the CH algorithm is cheaper and less limited by the lack of cross-sections. And, with a properly chosen production cut for secondaries, its accuracy for the problems of microdosimetry is satisfactory. In this work, calculations of the single-event (imparted energy ɛ) size distribution f1(ɛ) is described, for compartments in the Orlando electron micro beam. The results agree well with those obtained by use of the analog algorithm and reported in the literature. It is shown that substituting tissue with water in HeLa cells, and replacing Mylar with water of the same mass stopping power in the substrate, makes little difference. Additionally, the neighbor-to-target ratio of average event size RNT has been calculated as a function of the incident energy of the electrons. Comparison with analog results reported in the literature suggests that the average event size in neighbors, and hence the neighbor-to-target ratio, is sensitive to the selection of the energy threshold. Finally, the effect of finite beam radius on the event size distribution and the neighbor-to-target ratio has also been studied. All results presented suggest the condensed-history technique to provide an efficient and valuable alternative tool in the design of electron microbeams.
引用
收藏
页码:299 / 305
页数:6
相关论文
共 50 条
  • [41] HYBRID MONTE-CARLO - AN EFFICIENT ALGORITHM FOR CONDENSED MATTER SIMULATION
    CLAMP, ME
    BAKER, PG
    STIRLING, CJ
    BRASS, A
    JOURNAL OF COMPUTATIONAL CHEMISTRY, 1994, 15 (08) : 838 - 846
  • [42] MONTE-CARLO ALGORITHMS FOR THE ATOMISTIC SIMULATION OF CONDENSED POLYMER PHASES
    LEONTIDIS, E
    FORREST, BM
    WIDMANN, AH
    SUTER, UW
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1995, 91 (16): : 2355 - 2368
  • [43] Dosimetric measurements and Monte Carlo simulation for achieving uniform surface dose in pulsed electron beam irradiation facility
    Petwal, V. C.
    Rao, J. N.
    Dwivedi, Jishnu
    Senecha, V. K.
    Subbaiah, K. V.
    PRAMANA-JOURNAL OF PHYSICS, 2010, 74 (03): : 457 - 468
  • [44] Monte Carlo simulation of low-energy electron scattering and energy dissipation distribution
    Ren, LM
    Chen, BQ
    Tan, ZY
    SOLID-STATE AND INTEGRATED-CIRCUIT TECHNOLOGY, VOLS 1 AND 2, PROCEEDINGS, 2001, : 928 - 931
  • [45] AN IMPROVED ELECTRON MULTIPLE-SCATTERING DISTRIBUTION FOR MONTE-CARLO TRANSPORT SIMULATION
    ALBETERI, AA
    RAESIDE, DE
    MEDICAL PHYSICS, 1988, 15 (03) : 351 - 357
  • [46] Quantum versus classical Monte Carlo simulation of low-energy electron transport in condensed amorphous media
    Thomson, Rowan M.
    Kawrakow, Iwan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 : 179 - 188
  • [47] Monte Carlo simulation of Gauss-distribution beam spot in electron beam lithography
    Ren, L.M.
    Chen, B.Q.
    Weixi Jiagong Jishu/Microfabrication Technology, 2001, (03):
  • [48] Monte Carlo simulation of the CENBG microbeam and nanobeam lines with the Geant4 toolkit
    Incerti, S.
    Zhang, Q.
    Andersson, F.
    Moretto, Ph.
    Grime, G. W.
    Merchant, M. J.
    Nguyen, D. T.
    Habchi, C.
    Pouthier, T.
    Seznec, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 260 (01): : 20 - 27
  • [49] Dosimetric uncertainty of small cutouts in electron radiotherapy: Monte Carlo dosimetry evaluation
    Chow, J.
    Grigorov, G.
    MEDICAL PHYSICS, 2007, 34 (06) : 2443 - 2443