Condensed-history Monte Carlo simulation of the dosimetric distribution of electron microbeam

被引:0
|
作者
Yunzhi Ma
Hongyu Zhou
Yizhong Zhuo
机构
[1] Beijing Normal University,The Key Laboratory of Beam Technology and Material Modification of Ministry of Education, and Institute of Low Energy Nuclear Physics
[2] China Institute of Atomic Energy,undefined
来源
关键词
Analog Algorithm; Bystander Effect; Beam Radius; Average Event Size; Track Structure;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the dose distributions of an electron microbeam and to help optimization of its design, the condensed-history (CH) Monte Carlo simulation algorithm implemented in the Geant4 toolkit was selected as an alternative to the conventionally used analog algorithm. Compared to the analog algorithm, the CH algorithm is cheaper and less limited by the lack of cross-sections. And, with a properly chosen production cut for secondaries, its accuracy for the problems of microdosimetry is satisfactory. In this work, calculations of the single-event (imparted energy ɛ) size distribution f1(ɛ) is described, for compartments in the Orlando electron micro beam. The results agree well with those obtained by use of the analog algorithm and reported in the literature. It is shown that substituting tissue with water in HeLa cells, and replacing Mylar with water of the same mass stopping power in the substrate, makes little difference. Additionally, the neighbor-to-target ratio of average event size RNT has been calculated as a function of the incident energy of the electrons. Comparison with analog results reported in the literature suggests that the average event size in neighbors, and hence the neighbor-to-target ratio, is sensitive to the selection of the energy threshold. Finally, the effect of finite beam radius on the event size distribution and the neighbor-to-target ratio has also been studied. All results presented suggest the condensed-history technique to provide an efficient and valuable alternative tool in the design of electron microbeams.
引用
收藏
页码:299 / 305
页数:6
相关论文
共 50 条
  • [31] A dosimetric survey of different mammographic spectra using Monte Carlo simulation
    Delis, H
    Spyrou, G
    Tzanakos, G
    Panayiotakis, G
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 799 - 802
  • [32] Monte Carlo simulation of electron transport in AlGaAS
    Abou El-Ela, FM
    Modern Trends in Physics Research, 2005, 748 : 86 - 92
  • [33] Monte Carlo simulation of large electron fields
    Faddegon, Bruce A.
    Perl, Joseph
    Asai, Makoto
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (05): : 1497 - 1510
  • [34] A Dosimetric Comparison Between Superposition Algorithm and Monte Carlo Simulation for SBRT
    Luo, W.
    Meacham, A.
    Molloy, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Monte Carlo simulation of electron transport in PbTe
    Palankovski, V.
    Wagner, M.
    Heiss, W.
    NARROW GAP SEMICONDUCTORS 2007, 2008, 119 : 77 - +
  • [36] Monte Carlo simulation of transverse electron focusing
    Hornsey, RI
    JOURNAL OF APPLIED PHYSICS, 1996, 79 (02) : 832 - 841
  • [37] Comparison of Monte Carlo Simulation and Measurement for Determination of Dosimetric Leaf Gap
    Popple, R.
    Sawkey, D.
    Yuan, Y.
    Sullivan, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E262 - E262
  • [38] Monte Carlo simulation of dose distribution of radiotherapy
    Liu, YM
    Xue, DY
    Xu, XH
    Chen, Z
    System Simulation and Scientific Computing, Vols 1 and 2, Proceedings, 2005, : 422 - 426
  • [39] Monte Carlo simulation of photoelectron angular distribution
    Chen, YF
    SURFACE SCIENCE, 1997, 380 (2-3) : 199 - 209
  • [40] Dosimetric measurements and Monte Carlo simulation for achieving uniform surface dose in pulsed electron beam irradiation facility
    V. C. Petwal
    J. N. Rao
    Jishnu Dwivedi
    V. K. Senecha
    K. V. Subbaiah
    Pramana, 2010, 74 : 457 - 468