Monte-Carlo modeling of a NaI(Tl) scintillator

被引:0
|
作者
S. Ashrafi
S. Anvarian
S. Sobhanian
机构
[1] P.O. Box 51664,
[2] P.O. Box 51664,undefined
[3] P.O. Box 51664,undefined
关键词
Volume Source; Detector Crystal; GEANT Simulation; Detector Arrangement; Detector Description;
D O I
暂无
中图分类号
学科分类号
摘要
A NaI(Tl) scintillator detector has been modeled using GEANT simulation tool. Uniformity of the light collection efficiency was investigated by allowing a narrowly collimated beam of 59.5 keV g-rays to strike selected portion of the detector crystal. The simulated response function of the detector to the point source of photons was in good agreement with the measured one. Using the detector model, the simulated response function of the scintillator to the volume source of g-ray was also measured.
引用
收藏
页码:95 / 98
页数:3
相关论文
共 50 条
  • [1] Monte-Carlo modeling of a NaI(Tl) scintillator
    Ashrafi, S.
    Anvarian, S.
    Sobhanian, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 269 (01) : 95 - 98
  • [2] MONTE-CARLO CALCULATION OF THE RESPONSE OF NAI(TL) SCINTILLATION SPECTROMETERS
    BERGER, MJ
    DOGGETT, JA
    PHYSICAL REVIEW, 1955, 99 (02): : 663 - 663
  • [3] MONTE-CARLO SIMULATION OF THE RESPONSE OF NAI SCINTILLATOR TO MEDIUM-ENERGY NEUTRONS
    DUNPHY, PP
    CHUPP, EL
    JENSEN, CM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2): : 199 - 209
  • [4] MONTE-CARLO CALCULATIONS FOR ASYMMETRIC NAI(TL) AND BGO COMPTON SUPPRESSION SHIELDS
    BYRNE, AP
    DRACOULIS, GD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 234 (02): : 281 - 287
  • [5] Calibration of buried NaI(Tl) scintillator detectors for natural radionuclide measurement based on Monte Carlo modelling
    Chambon, A.
    Klinkby, E. B.
    Bu, M.
    Murray, A. S.
    Kook, M.
    Olesen, H.
    Nielsen, K. B.
    Lauritzen, B.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [6] Monte Carlo simulation of a NaI(Tl) detector efficiency
    Akkurt, Iskender
    Waheed, Faez
    Akyildirim, Hakan
    Gunoglu, Kadir
    RADIATION PHYSICS AND CHEMISTRY, 2020, 176
  • [7] MONTE-CARLO CALCULATION OF INTRINSIC GAMMA-RAY EFFICIENCIES OF CYLINDRICAL NAI(TL) DETECTORS
    GROSSWENDT, B
    WAIBEL, E
    NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (01): : 25 - 28
  • [8] Study of the NaI(Tl) efficiency by Monte Carlo method
    Jehouani, A
    Ichaoui, R
    Boulkheir, M
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 887 - 891
  • [9] The Monte-Carlo simulation on a scintillator neutron detector
    WU Chong
    TANG Bin
    SUN ZhiJia
    ZHANG Qiang
    YANG Zhen
    LUO Wei
    WANG Tuo
    Science China(Physics,Mechanics & Astronomy), 2013, Mechanics & Astronomy)2013 (10) : 1892 - 1896
  • [10] MONTE-CARLO CALCULATION OF ACCURATE RESPONSE FUNCTIONS FOR A NAI(TL) DETECTOR FOR GAMMA-RAYS
    SAITO, K
    MORIUCHI, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 299 - 308