Catalytic brdicka-type systems in alternating-current square-wave voltammetry

被引:0
|
作者
V. I. Gorokhovskaya
机构
[1] Kazan State Technological University,Department of Chemistry and Petroleum Chemistry
来源
关键词
Cobalt; Cystine; Catalytic System; Indicator System; Peak Height Ratio;
D O I
暂无
中图分类号
学科分类号
摘要
Conventional kinetic and adsorption parameters of signals detected by alternating-current squarewave voltammetry in the catalytic systems cobalt(II)-NH3-cysteine (cystine) and nickel(II)-NH3-cysteine (cystine) in the presence of excess catalyst (metal ions) were discussed. The parameters for the optimization of the detected signals (mercury column height and mercury dropping rate) were considered. The characteristics of the cobalt(II)-NH3-cystine-containing protein indicator system were qualitatively compared with those of the model cobalt(H)-NH3-cystine system.
引用
收藏
页码:358 / 362
页数:4
相关论文
共 50 条
  • [41] SQUARE-WAVE VOLTAMMETRY FOR A PSEUDO-1ST-ORDER CATALYTIC PROCESS
    ZENG, J
    OSTERYOUNG, RA
    ANALYTICAL CHEMISTRY, 1986, 58 (13) : 2766 - 2771
  • [42] The surface catalytic mechanism: a comparative study with square-wave and staircase cyclic voltammetry
    Mirceski, V
    Gulaboski, R
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2003, 7 (03) : 157 - 165
  • [43] INVESTIGATION INTO ARC-WELDING PROCESS WITH SQUARE-WAVE ALTERNATING CURRENT
    KOROTKOVA, GM
    SLAVIN, GA
    FILIPPOV, MA
    WELDING PRODUCTION, 1971, 18 (10): : 6 - +
  • [44] Square-wave voltammetry of human blood serum
    Kokoskarova, Pavlinka
    Stojanov, Leon
    Najkov, Kosta
    Ristovska, Natasha
    Ruskovska, Tatjana
    Skrzypek, Slawomira
    Mirceski, Valentin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [45] Ohmic drop effects in square-wave voltammetry
    Mirceski, V
    Lovric, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 497 (1-2): : 114 - 124
  • [46] Square-wave voltammetry detection for capillary electrophoresis
    Gerhardt, GC
    Cassidy, RM
    Baranski, AS
    ANALYTICAL CHEMISTRY, 1998, 70 (10) : 2167 - 2173
  • [47] Adsorptive stripping square-wave voltammetry of creatine
    Stojanova, K
    Gulaboski, R
    Mireceski, V
    Petrovska-Jovanovic, S
    ANALYTICAL LETTERS, 1999, 32 (15) : 2937 - 2950
  • [48] DIFFERENTIAL SIMPLE OSCILLOGRAPHIC VOLTAMMETRY USING PULSE-WAVE ALTERNATING-CURRENT AS POLARIZATION CURRENT
    ZHENG, JB
    ZHAO, MR
    ZHU, XH
    SU, YX
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (08): : 1209 - 1211
  • [49] SQUARE-WAVE VOLTAMMETRY FOR PLATING SOLUTION ANALYSES
    ROTHSTEIN, ML
    METAL FINISHING, 1984, 82 (10) : 35 - 39
  • [50] VERY FAST SQUARE-WAVE VOLTAMMETRY AT MICROELECTRODES
    ODEA, JJ
    MANTZ, R
    KHALED, M
    OSTERYOUNG, RA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 111 - ANYL