Cost viability of a base isolation system for the seismic protection of a steel high-rack structure

被引:0
|
作者
Vojko Kilar
Simon Petrovčič
David Koren
Simon Šilih
机构
[1] University of Ljubljana,Faculty of Architecture
[2] University of Maribor,Faculty of Civil Engineering
关键词
rack structures; base isolation; cost efficiency; mass eccentricity; repair costs; downtime costs; content damage costs;
D O I
暂无
中图分类号
学科分类号
摘要
In this study the effects and costs of implementing a base isolation system for the mitigation of the seismic risk of an existing externally-braced steel frame rack structure are analysed by means of nonlinear static (pushover) analysis. Various plan asymmetric variants, with different realistic distributions of the payload mass and occupancy levels, have been investigated under two seismic intensities. The results obtained are presented as floor plan projection envelopes of the top displacements and as plastic hinge damage patterns of the superstructure. In the presented cost evaluation, the cost of the implementation of the proposed base isolation system is compared with the estimated costs of structural repairs to the damaged structural members of the superstructure, as well as with estimated expenses of the downtime period and content damage. The results have shown that base isolation is, in general, not economically feasible for lower ground motion intensities, whereas it could be of great benefit in the case of moderate and high intensities. A simple rough cost estimation study, based on the obtained plastic hinge patterns, showed that the inclusion of the downtime period costs and content damage costs might be important parameters, which — if taken into account — could make such an isolation system viable also for lower ground motion intensities. The other benefits brought by seismic isolation, such as savings on the building design costs, reductions in the threat to employees’ lives, and others, were, however, not included in the presented study. The comparison is done only for two deterministic scenarios of seismic attack, e.g. for design ground motion intensity (ag =0.175 g) and for increased intensity with ag =0.25 g indicating the Maximum Considered Earthquake level.
引用
收藏
页码:253 / 263
页数:10
相关论文
共 50 条
  • [41] Optimal design and seismic performance of hybrid base isolation system
    Li, Chun-Xiang
    Long, Qiu-Yu
    Cao, Li-Yuan
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2024, 37 (01): : 137 - 147
  • [42] Seismic performance of a Low-Cost base isolation system for unreinforced brick Masonry buildings in developing countries
    Losanno, Daniele
    Ravichandran, Nagavinothini
    Parisi, Fulvio
    Calabrese, Andrea
    Serino, Giorgio
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 141
  • [43] Experimental and numerical evaluation of model steel structure using the stiffness decoupler seismic isolation system
    Hu, KK
    Zhu, HH
    Kirmser, PG
    SMART STRUCTURES AND MATERIALS 2000: DAMPING AND ISOLATION, 2000, 3989 : 414 - 422
  • [44] Shake table testing and numerical modelling of a steel pallet racking structure with a seismic isolation system
    Tagliafierro, Bonaventura
    Montuori, Rosario
    Castellano, Maria Gabriella
    THIN-WALLED STRUCTURES, 2021, 164
  • [45] Enhanced performance through a dual isolation seismic protection system
    Becker, Tracy C.
    Ezazi, Ashkan
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (01): : 72 - 89
  • [46] Reduction of seismic response of mechanical system by base isolation system with friction bearing
    Aoki, Shigeru
    Tominaga, Kazutoshi
    Nishimura, Tadashi
    Kanazawa, Mitsuo
    Nakanishi, Yuji
    Otaka, Takeshi
    Inagaki, Mitsuyoshi
    Kawaguchi, Sumio
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2007, VOL 8: SEISMIC ENGINEERING, 2007, : 177 - 183
  • [47] SEISMIC RESPONSE OF TORSIONALLY COUPLED STRUCTURE WITH ELASTOPLASTIC BASE-ISOLATION
    JANGID, RS
    DATTA, TK
    ENGINEERING STRUCTURES, 1994, 16 (04) : 256 - 262
  • [48] Seismic Decrease Coefficient of Base Isolation Structure Based on Stiffness Ratio
    Shang S.
    Wang Y.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2023, 50 (03): : 23 - 31
  • [49] Seismic fragility analysis of base-isolation structure connected with large span special-shaped steel corridor
    Pan, Yi
    Bao, Yunlei
    Liu, Yongxin
    Hu, Siyuan
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2021, 54 (02): : 20 - 29
  • [50] Optimal design of a base isolated system for a high-rise steel structure
    Kaplan, H
    Seireg, A
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (02): : 287 - 302