Cost viability of a base isolation system for the seismic protection of a steel high-rack structure

被引:0
|
作者
Vojko Kilar
Simon Petrovčič
David Koren
Simon Šilih
机构
[1] University of Ljubljana,Faculty of Architecture
[2] University of Maribor,Faculty of Civil Engineering
关键词
rack structures; base isolation; cost efficiency; mass eccentricity; repair costs; downtime costs; content damage costs;
D O I
暂无
中图分类号
学科分类号
摘要
In this study the effects and costs of implementing a base isolation system for the mitigation of the seismic risk of an existing externally-braced steel frame rack structure are analysed by means of nonlinear static (pushover) analysis. Various plan asymmetric variants, with different realistic distributions of the payload mass and occupancy levels, have been investigated under two seismic intensities. The results obtained are presented as floor plan projection envelopes of the top displacements and as plastic hinge damage patterns of the superstructure. In the presented cost evaluation, the cost of the implementation of the proposed base isolation system is compared with the estimated costs of structural repairs to the damaged structural members of the superstructure, as well as with estimated expenses of the downtime period and content damage. The results have shown that base isolation is, in general, not economically feasible for lower ground motion intensities, whereas it could be of great benefit in the case of moderate and high intensities. A simple rough cost estimation study, based on the obtained plastic hinge patterns, showed that the inclusion of the downtime period costs and content damage costs might be important parameters, which — if taken into account — could make such an isolation system viable also for lower ground motion intensities. The other benefits brought by seismic isolation, such as savings on the building design costs, reductions in the threat to employees’ lives, and others, were, however, not included in the presented study. The comparison is done only for two deterministic scenarios of seismic attack, e.g. for design ground motion intensity (ag =0.175 g) and for increased intensity with ag =0.25 g indicating the Maximum Considered Earthquake level.
引用
收藏
页码:253 / 263
页数:10
相关论文
共 50 条
  • [1] Cost viability of a base isolation system for the seismic protection of a steel high-rack structure
    Kilar, Vojko
    Petrovcic, Simon
    Koren, David
    Silih, Simon
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2013, 13 (02) : 253 - 263
  • [2] Financial aspects of a seismic base isolation system for a steel high-rack structure
    Kilar, V.
    Petrovcic, S.
    Silih, S.
    Koren, D.
    INFORMES DE LA CONSTRUCCION, 2013, 65 (532) : 533 - 543
  • [3] Seismic analysis of an asymmetric fixed base and base-isolated high-rack steel structure
    Kilar, Vojko
    Petrovcic, Simon
    Koren, David
    Silih, Simon
    ENGINEERING STRUCTURES, 2011, 33 (12) : 3471 - 3482
  • [4] Effects of Horizontal and Vertical Mass-Asymmetric Distributions on the Seismic Response of a High-Rack Steel Structure
    Petrovcic, Simon
    Kilar, Vojko
    ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (11) : 1977 - 1988
  • [5] Seismic performance of a high-rack warehouse structure with vertical and horizontal mass asymmetries
    Petrovcic, Simon
    Kilar, Vojko
    STESSA 2012: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2012, : 345 - 350
  • [6] Low-Cost Base-Isolation System for Seismic Protection of Rural Buildings
    Nanda, Radhikesh P.
    Shrikhande, Manish
    Agarwal, Pankaj
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2016, 21 (01)
  • [7] COST ANALYSIS OF A BUILDING WITH SEISMIC BASE ISOLATION SYSTEM
    Pekgokgoz, R. Kadir
    Gurel, M. Arif
    Komur, Mahmut
    CIli, Feridun
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2007, 25 (03): : 236 - 246
  • [8] SEISMIC BASE ISOLATION FOR STEEL STRUCTURES
    STIEMER, SF
    BARWIG, BB
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1985, 12 (01) : 73 - 81
  • [9] Seismic Base Isolation of Steel Frame Structure by Hollow Rubber Bearings
    Adnan, Azlan
    Tiong, Patrick Liq Yee
    Sunaryati, Jati
    Ghazali, Mohd Zulkifli Mohd
    Ab Malek, Kamarudin
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2011, 24 (04): : 841 - 853
  • [10] SEISMIC PROTECTION OF BUILDING STRUCTURE WITH AN INNOVATIVE PASSIVE ISOLATION SYSTEM
    Chen, Xi
    Shan, Jiazeng
    Shi, Weixing
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 1378 - 1386