Automated detection of chronic kidney disease using higher-order features and elongated quinary patterns from B-mode ultrasound images

被引:4
|
作者
Acharya, U. Rajendra [1 ,2 ,3 ]
Meiburger, Kristen M. [4 ]
Koh, Joel En Wei [1 ]
Hagiwara, Yuki [1 ]
Oh, Shu Lih [1 ]
Leong, Sook Sam [5 ,7 ]
Ciaccio, Edward J. [6 ]
Wong, Jeannie Hsiu Ding [5 ,8 ]
Shah, Mohammad Nazri Md [5 ,8 ]
Molinari, Filippo [4 ]
Ng, Kwan Hoong [5 ,8 ]
机构
[1] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore 599489, Singapore
[2] Singapore Univ Social Sci, Sch Sci & Technol, Dept Biomed Engn, Singapore, Singapore
[3] Taylors Univ, Fac Hlth & Med Sci, Sch Med, Subang Jaya, Malaysia
[4] Politecn Torino, Dept Elect & Telecommun, Turin, Italy
[5] Univ Malaya, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[6] Columbia Univ, Dept Med, New York, NY USA
[7] Univ Malaya, Dept Biomed Imaging, Med Ctr, Kuala Lumpur, Malaysia
[8] Univ Malaya, Res Imaging Ctr, Kuala Lumpur, Malaysia
来源
NEURAL COMPUTING & APPLICATIONS | 2020年 / 32卷 / 15期
关键词
Chronic kidney disease; Bispectrum; Cumulants; Elongated quinary pattern; Locality sensitive discriminant analysis; Ultrasound; DEEP; ENTROPY;
D O I
10.1007/s00521-019-04025-y
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Chronic kidney disease (CKD) is a continuing loss of kidney function, and early detection of this disease is fundamental to halting its progression to end-stage disease. Numerous methods have been proposed to detect CKD, mainly focusing on classification based upon peripheral clinical parameters and quantitative ultrasound parameters that must be manually calculated, or on shear wave elastography. No studies have been found that detect the presence or absence of CKD based solely from one B-mode ultrasound image. In this work, we propose an automated system to detect chronic kidney disease utilizing only the automatic extraction of features from a B-mode ultrasound image of the kidney, with a database of 405 images. Higher-order bispectrum and cumulants, and elongated quinary patterns, are extracted from each image to provide a final total of 24,480 features per image. These features were subjected to a locality sensitive discriminant analysis (LSDA) technique, which provides 30 LSDA coefficients. The coefficients were arranged according to theirtvalue and inserted into various classifiers, to yield the best diagnostic accuracy using the least number of features. The best performance was obtained using a support vector machine and a radial basis function, utilizing only five features, resulting in an accuracy of 99.75%, a sensitivity of 100%, and a specificity of 99.57%. Based upon these findings, it is evident that the technique accurately and automatically identifies subjects with and without CKD from B-mode ultrasound images.
引用
收藏
页码:11163 / 11172
页数:10
相关论文
共 50 条
  • [31] ROBUST COMMON CAROTID ARTERY LUMEN DETECTION IN B-MODE ULTRASOUND IMAGES USING LOCAL PHASE SYMMETRY
    Rouco, Jose
    Campilho, Aurelio
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 929 - 933
  • [32] A Note of Liver Cirrhosis Classification on M-Mode Ultrasound Images by Higher-Order Local Auto-Correlation Features
    Fujino, K.
    Mitani, Y.
    Hayashi, T.
    Fujita, Y.
    Hamamoto, Y.
    Segawa, M.
    Terai, S.
    Sakaida, I.
    2013 INTERNATIONAL CONFERENCE OF SOFT COMPUTING AND PATTERN RECOGNITION (SOCPAR), 2013, : 50 - 53
  • [33] Fusion of B-mode and shear wave elastography ultrasound features for automated detection of axillary lymph node metastasis in breast carcinoma
    Pham, The-Hanh
    Faust, Oliver
    Koh, Joel En Wei
    Ciaccio, Edward J.
    Barua, Prabal D.
    Omar, Norlia
    Ng, Wei Lin
    Ab Mumin, Nazimah
    Rahmat, Kartini
    Acharya, U. Rajendra
    EXPERT SYSTEMS, 2022, 39 (05)
  • [34] Study of Speckle Noise Reduction from Ultrasound B-mode Images using Different Filtering Techniques
    Tasnim, Tanpia
    Shuvo, Md. Maruf Hossain
    Hasan, Sabbir
    2017 4TH INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL ENGINEERING (ICAEE), 2017, : 229 - 234
  • [35] Automated detection of calcified plaque using higher-order spectra cumulant technique in computer tomography angiography images
    Acharya, U. Rajendra
    Meiburger, Kristen M.
    Koh, Joel E. W.
    Ciaccio, Edward J.
    Vicnesh, Jahmunah
    Tan, Sock K.
    Wong, Jeannie H. D.
    Aman, Raja R. A. R.
    Ng, Kwan H.
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2020, 30 (02) : 285 - 297
  • [36] Ovarian Follicle Classification using Numerical and B-mode Image Features from Ultrasound Scanning Devices
    Nii, Manabu
    Kato, Yusuke
    Morimoto, Masakazu
    Kobashi, Shoji
    Kamiura, Naotake
    Hata, Yutaka
    Imawaki, Setsuro
    Ishikawa, Tomomoto
    Matsubayashi, Hidehiko
    2018 JOINT 7TH INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV) AND 2018 2ND INTERNATIONAL CONFERENCE ON IMAGING, VISION & PATTERN RECOGNITION (ICIVPR), 2018, : 222 - 227
  • [37] Link between automated coronary calcium volumes from intravascular ultrasound to automated carotid IMT from B-mode ultrasound in coronary artery disease population
    Araki, T.
    Ikeda, N.
    Molinari, F.
    Dey, N.
    Acharjee, S.
    Saba, L.
    Suri, J. S.
    INTERNATIONAL ANGIOLOGY, 2014, 33 (04) : 392 - 403
  • [38] Automated bone contour detection in ultrasound B-mode images for minimally invasive registration in computer-assisted surgery -: an in vitro evaluation
    Kowal, Jens
    Amstutz, Christoph
    Langlotz, Frank
    Talib, Haydar
    Ballester, Miguel Gonzalez
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (04): : 341 - 348
  • [39] Automated detection of the carotid artery wall in longitudinal B-mode images using active contours initialized by the Hough transform
    Matsakou, A. I.
    Golemati, S.
    Stoitsis, J. S.
    Nikita, K. S.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 571 - 574
  • [40] MULTISCALE EDGE DETECTION AND GRADIENT VECTOR FLOW SNAKES FOR AUTOMATED IDENTIFICATION OF THE CAROTID ARTERY WALL IN LONGITUDINAL B-MODE ULTRASOUND IMAGES
    Matsakou, A. I.
    Tsiaparas, N.
    Golemati, S.
    Nikita, K. S.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1599 - 1602