Automated detection of chronic kidney disease using higher-order features and elongated quinary patterns from B-mode ultrasound images

被引:4
|
作者
Acharya, U. Rajendra [1 ,2 ,3 ]
Meiburger, Kristen M. [4 ]
Koh, Joel En Wei [1 ]
Hagiwara, Yuki [1 ]
Oh, Shu Lih [1 ]
Leong, Sook Sam [5 ,7 ]
Ciaccio, Edward J. [6 ]
Wong, Jeannie Hsiu Ding [5 ,8 ]
Shah, Mohammad Nazri Md [5 ,8 ]
Molinari, Filippo [4 ]
Ng, Kwan Hoong [5 ,8 ]
机构
[1] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore 599489, Singapore
[2] Singapore Univ Social Sci, Sch Sci & Technol, Dept Biomed Engn, Singapore, Singapore
[3] Taylors Univ, Fac Hlth & Med Sci, Sch Med, Subang Jaya, Malaysia
[4] Politecn Torino, Dept Elect & Telecommun, Turin, Italy
[5] Univ Malaya, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[6] Columbia Univ, Dept Med, New York, NY USA
[7] Univ Malaya, Dept Biomed Imaging, Med Ctr, Kuala Lumpur, Malaysia
[8] Univ Malaya, Res Imaging Ctr, Kuala Lumpur, Malaysia
来源
NEURAL COMPUTING & APPLICATIONS | 2020年 / 32卷 / 15期
关键词
Chronic kidney disease; Bispectrum; Cumulants; Elongated quinary pattern; Locality sensitive discriminant analysis; Ultrasound; DEEP; ENTROPY;
D O I
10.1007/s00521-019-04025-y
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Chronic kidney disease (CKD) is a continuing loss of kidney function, and early detection of this disease is fundamental to halting its progression to end-stage disease. Numerous methods have been proposed to detect CKD, mainly focusing on classification based upon peripheral clinical parameters and quantitative ultrasound parameters that must be manually calculated, or on shear wave elastography. No studies have been found that detect the presence or absence of CKD based solely from one B-mode ultrasound image. In this work, we propose an automated system to detect chronic kidney disease utilizing only the automatic extraction of features from a B-mode ultrasound image of the kidney, with a database of 405 images. Higher-order bispectrum and cumulants, and elongated quinary patterns, are extracted from each image to provide a final total of 24,480 features per image. These features were subjected to a locality sensitive discriminant analysis (LSDA) technique, which provides 30 LSDA coefficients. The coefficients were arranged according to theirtvalue and inserted into various classifiers, to yield the best diagnostic accuracy using the least number of features. The best performance was obtained using a support vector machine and a radial basis function, utilizing only five features, resulting in an accuracy of 99.75%, a sensitivity of 100%, and a specificity of 99.57%. Based upon these findings, it is evident that the technique accurately and automatically identifies subjects with and without CKD from B-mode ultrasound images.
引用
收藏
页码:11163 / 11172
页数:10
相关论文
共 50 条
  • [21] Anomaly Detection for Capsule Endoscopy Images Using Higher-order Local Auto Correlation Features
    Hu, Erzhong
    Nosato, Hirokazu
    Sakanashi, Hidenori
    Murakawa, Masahiro
    PROCEEDINGS 2012 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2012, : 2289 - 2293
  • [22] Automated liver tissue segmentation in point of care ultrasound b-mode images using U-Net
    Garcia, Raul Blazquez
    Lightstone, Adi
    Ibrahim, Miriam Naim
    El Kaffas, Ahmed
    CLINICAL CANCER RESEARCH, 2021, 27 (05)
  • [23] Fully Automated Analysis of Muscle Architecture from B-Mode Ultrasound Images with DL_Track_US
    Ritsche, Paul
    V. Franchi, Martino
    Faude, Oliver
    Finni, Taija
    Seynnes, Olivier
    Cronin, Neil J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (02): : 258 - 267
  • [24] Estimation of Ultrasound Echogenicity Map from B-Mode Images Using Convolutional Neural Network
    Shen, Che-Chou
    Yang, Jui-En
    SENSORS, 2020, 20 (17) : 1 - 14
  • [25] Estimation of ultrasound echogenicity map from B-mode images using convolutional neural network
    Yang, Jui-En
    Shen, Che-Chou
    Lin, Ri-Cheng
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [26] Transfer learning from RF to B-mode temporal enhanced ultrasound features for prostate cancer detection
    Shekoofeh Azizi
    Parvin Mousavi
    Pingkun Yan
    Amir Tahmasebi
    Jin Tae Kwak
    Sheng Xu
    Baris Turkbey
    Peter Choyke
    Peter Pinto
    Bradford Wood
    Purang Abolmaesumi
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 1111 - 1121
  • [27] Transfer learning from RF to B-mode temporal enhanced ultrasound features for prostate cancer detection
    Azizi, Shekoofeh
    Mousavi, Parvin
    Yan, Pingkun
    Tahmasebi, Amir
    Kwak, Jin Tae
    Xu, Sheng
    Turkbey, Baris
    Choyke, Peter
    Pinto, Peter
    Wood, Bradford
    Abolmaesumi, Purang
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (07) : 1111 - 1121
  • [28] Automated Lumen Segmentation and Estimation of Numerical Attributes of Common Carotid Artery Using Longitudinal B-Mode Ultrasound Images
    Ramasamy, Nandakumar
    Jayanthi, K. B.
    2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 306 - 309
  • [29] Detection of Gestational Diabetes Mellitus and Influence on Perinatal Outcomes from B-Mode Ultrasound Images Using Deep Neural Network
    Liu, Yuhui
    Wang, Yu
    Zhang, Yang
    Cheng, Rulei
    SCIENTIFIC PROGRAMMING, 2021, 2021
  • [30] Cancer Detection from Pathological Images using Higher-order Local Autocorrelation Feature
    Qu, Jia
    Nosato, Hirokazu
    Sakanashi, Hidenori
    Terai, Kensuke
    Hiruta, Nobuyuki
    PROCEEDINGS OF 2012 IEEE 11TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP) VOLS 1-3, 2012, : 1198 - +