Automated detection of chronic kidney disease using higher-order features and elongated quinary patterns from B-mode ultrasound images

被引:4
|
作者
Acharya, U. Rajendra [1 ,2 ,3 ]
Meiburger, Kristen M. [4 ]
Koh, Joel En Wei [1 ]
Hagiwara, Yuki [1 ]
Oh, Shu Lih [1 ]
Leong, Sook Sam [5 ,7 ]
Ciaccio, Edward J. [6 ]
Wong, Jeannie Hsiu Ding [5 ,8 ]
Shah, Mohammad Nazri Md [5 ,8 ]
Molinari, Filippo [4 ]
Ng, Kwan Hoong [5 ,8 ]
机构
[1] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore 599489, Singapore
[2] Singapore Univ Social Sci, Sch Sci & Technol, Dept Biomed Engn, Singapore, Singapore
[3] Taylors Univ, Fac Hlth & Med Sci, Sch Med, Subang Jaya, Malaysia
[4] Politecn Torino, Dept Elect & Telecommun, Turin, Italy
[5] Univ Malaya, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[6] Columbia Univ, Dept Med, New York, NY USA
[7] Univ Malaya, Dept Biomed Imaging, Med Ctr, Kuala Lumpur, Malaysia
[8] Univ Malaya, Res Imaging Ctr, Kuala Lumpur, Malaysia
来源
NEURAL COMPUTING & APPLICATIONS | 2020年 / 32卷 / 15期
关键词
Chronic kidney disease; Bispectrum; Cumulants; Elongated quinary pattern; Locality sensitive discriminant analysis; Ultrasound; DEEP; ENTROPY;
D O I
10.1007/s00521-019-04025-y
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Chronic kidney disease (CKD) is a continuing loss of kidney function, and early detection of this disease is fundamental to halting its progression to end-stage disease. Numerous methods have been proposed to detect CKD, mainly focusing on classification based upon peripheral clinical parameters and quantitative ultrasound parameters that must be manually calculated, or on shear wave elastography. No studies have been found that detect the presence or absence of CKD based solely from one B-mode ultrasound image. In this work, we propose an automated system to detect chronic kidney disease utilizing only the automatic extraction of features from a B-mode ultrasound image of the kidney, with a database of 405 images. Higher-order bispectrum and cumulants, and elongated quinary patterns, are extracted from each image to provide a final total of 24,480 features per image. These features were subjected to a locality sensitive discriminant analysis (LSDA) technique, which provides 30 LSDA coefficients. The coefficients were arranged according to theirtvalue and inserted into various classifiers, to yield the best diagnostic accuracy using the least number of features. The best performance was obtained using a support vector machine and a radial basis function, utilizing only five features, resulting in an accuracy of 99.75%, a sensitivity of 100%, and a specificity of 99.57%. Based upon these findings, it is evident that the technique accurately and automatically identifies subjects with and without CKD from B-mode ultrasound images.
引用
收藏
页码:11163 / 11172
页数:10
相关论文
共 50 条
  • [1] Retraction Note: Automated detection of chronic kidney disease using higher-order features and elongated quinary patterns from B-mode ultrasound images
    U. Rajendra Acharya
    Kristen M. Meiburger
    Joel En Wei Koh
    Yuki Hagiwara
    Shu Lih Oh
    Sook Sam Leong
    Edward J. Ciaccio
    Jeannie Hsiu Ding Wong
    Mohammad Nazri Md Shah
    Filippo Molinari
    Kwan Hoong Ng
    Neural Computing and Applications, 2024, 36 (24) : 15217 - 15217
  • [2] A Liver Cirrhosis Classification on B-Mode Ultrasound Images by the Use of Higher Order Local Autocorrelation Features
    Sasaki, Kenya
    Mitani, Yoshihiro
    Fujita, Yusuke
    Hamamoto, Yoshihiko
    Sakaida, Isao
    EIGHTH INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2016), 2017, 10225
  • [3] Automated fatty liver disease detection in point-of-care ultrasound B-mode images
    Ibrahim, Miriam Naim
    Blazquez-Garcia, Raul
    Lightstone, Adi
    Meng, Fankun
    Bhat, Mamatha
    El Kaffas, Ahmed
    Ukwatta, Eranga
    JOURNAL OF MEDICAL IMAGING, 2023, 10 (03)
  • [4] Automated detection of skeletal muscle twitches from B-mode ultrasound images: An application to Motor Neuron Disease
    Harding, Peter J.
    Hodson-Tole, Emma F.
    Cunningham, Ryan
    Loram, Ian
    Costen, Nicholas
    2012 21ST INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR 2012), 2012, : 2630 - 2633
  • [5] Automated detection of glaucoma using elongated quinary patterns technique with optical coherence tomography angiogram images
    Chan, Yam Meng
    Ng, E. Y. K.
    Jahmunah, V
    Koh, Joel En Wei
    Oh, Shu Lih
    Han, Wei Shan
    Yip, Leonard Wei Leon
    Acharya, U. Rajendra
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 69 (69)
  • [6] B-mode and Doppler ultrasound of chronic kidney disease in dogs and cats
    Nathália Bragato
    Naida Cristina Borges
    Maria Clorinda Soares Fioravanti
    Veterinary Research Communications, 2017, 41 : 307 - 315
  • [7] B-mode and Doppler ultrasound of chronic kidney disease in dogs and cats
    Bragato, Nathalia
    Borges, Naida Cristina
    Soares Fioravanti, Maria Clorinda
    VETERINARY RESEARCH COMMUNICATIONS, 2017, 41 (04) : 307 - 315
  • [8] A COMPARISON OF TWO ALGORITHMS FOR AUTOMATED STONE DETECTION IN CLINICAL B-MODE ULTRASOUND IMAGES OF THE ABDOMEN
    Gupta, Abhinav
    Gosain, Bhuvan
    Kaushal, Sunanda
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2010, 24 (05) : 341 - 362
  • [9] A comparison of two algorithms for automated stone detection in clinical B-mode ultrasound images of the abdomen
    Abhinav Gupta
    Bhuvan Gosain
    Sunanda Kaushal
    Journal of Clinical Monitoring and Computing, 2010, 24 : 341 - 362
  • [10] Assessment of carotid atherosclerosis from B-mode ultrasound images using directional multiscale texture features
    Tsiaparas, N. N.
    Golemati, S.
    Andreadis, I.
    Stoitsis, J.
    Valavanis, I.
    Nikita, K. S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (11)