Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation

被引:0
|
作者
Basil Mathai
Santanu Dhara
Sanjay Gupta
机构
[1] Indian Institute of Technology Kharagpur,Department of Mechanical Engineering
[2] Indian Institute of Technology Kharagpur,School of Medical Science and Technology
关键词
Finite element analysis; Proximal femur; Total hip replacement; Bone remodelling; Bone orthotropy;
D O I
暂无
中图分类号
学科分类号
摘要
Peri-prosthetic bone adaptation has usually been predicted using subject-specific finite element analysis in combination with remodelling algorithms and assuming isotropic bone material property. The objective of the study is to develop an orthotropic bone remodelling algorithm for evaluation of peri-prosthetic bone adaptation in the uncemented implanted femur. The simulations considered loading conditions from a variety of daily activities. The orthotropic algorithm was tested on 2D and 3D models of the intact femur for verification of predicted results. The predicted orthotropic directionality, based on principal stress directions, was in agreement with the trabecular orientation in a micro-CT data of proximal femur. The validity of the proposed strain-based algorithm was assessed by comparing the predicted results of the orthotropic model with those of the strain-energy-density-based isotropic formulation. Despite agreement in cortical densities (R=0.71)\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(R = 0.71)$$\end{document}, the isotropic remodelling algorithm tends to predict relatively higher values around the distal tip of the implant as compared to the orthotropic model. Both formulations predicted 4–8% bone resorption in the proximal femur. A linear regression analysis revealed a significant correlation (R=0.99)\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(R = 0.99)$$\end{document} between the stresses and strains on the cortex of the proximal femur, predicted by the isotropic and orthotropic formulations. Despite reasonable agreement in peri-prosthetic bone density distributions, the quantitative differences with isotropic model predictions highlight the combined influences of bone orthotropy and mechanical stimulus in the adaptation process.
引用
收藏
页码:1115 / 1134
页数:19
相关论文
共 50 条
  • [41] A comparative finite element simulation of stress in dental implant–bone interface using isotropic and orthotropic material models in three mastication cycles
    Ramezan Ali Taheri
    Amin Jarrahi
    Gholamreza Farnoosh
    Alireza Karimi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2018, 40
  • [42] Comparison of radiographic and histological assessment of peri-implant bone around oral implants
    Stokholm, Rie
    Spin-Neto, Rubens
    Nyengaard, Jens R.
    Isidor, Flemming
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (07) : 782 - 786
  • [43] Effect of femoral canal shape on mechanical stress distribution and adaptive bone remodelling around a cementless tapered-wedge stem
    Oba, M.
    Inaba, Y.
    Kobayashi, N.
    Ike, H.
    Tezuka, T.
    Saito, T.
    BONE & JOINT RESEARCH, 2016, 5 (09): : 362 - 369
  • [44] Periprosthetic bone remodelling after cementless total hip replacement - A prospective comparison of two different implant designs
    Ang, KC
    De, SD
    Goh, JCH
    Low, SL
    Bose, K
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04): : 675 - 679
  • [45] A comparative finite element simulation of stress in dental implant-bone interface using isotropic and orthotropic material models in three mastication cycles
    Taheri, Ramezan Ali
    Jarrahi, Amin
    Farnoosh, Gholamreza
    Karimi, Alireza
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (10)
  • [46] Nanometer-grooved topography stimulates trabecular bone regeneration around a concave implant in a rat femoral medulla model
    Klymov, Alexey
    te Riet, Joost
    Mulder, Peter
    Gardeniers, Johannes G. E.
    Jansen, John A.
    Walboomers, X. Frank
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2016, 12 (08) : 2283 - 2290
  • [47] Investigating the effect of remodelling signal type on the finite element based predictions of bone remodelling around the thrust plate prosthesis: a patient-specific comparison
    Schmitz, MJ
    Clift, SE
    Taylor, WR
    Hertig, D
    Warner, MD
    Ploeg, HL
    Bereiter, H
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H6) : 417 - 424
  • [48] Periprosthetic bone remodelling around a prosthesis for distal femoral tumours - Measurement by dual-energy x-ray absorptiometry (DEXA)
    Lan, F
    Wunder, JS
    Griffin, AM
    Davis, AM
    Bell, RS
    White, LM
    Ichise, M
    Cole, W
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (01): : 120 - 125
  • [49] Numerical investigation of bone remodelling around immediately loaded dental implants using sika deer (Cervus nippon) antlers as implant bed
    He, Yun
    Hasan, Istabrak
    Keilig, Ludger
    Fischer, Dominik
    Ziegler, Luisa
    Abboud, Marcus
    Wahl, Gerhard
    Bourauel, Christoph
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (04) : 359 - 369
  • [50] Cortical and interfacial bone changes around a non-cemented hip implant: Simulations using a combined strain/damage remodelling algorithm
    Scannell, Paul T.
    Prendergast, Patrick J.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) : 477 - 488