Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation

被引:0
|
作者
Basil Mathai
Santanu Dhara
Sanjay Gupta
机构
[1] Indian Institute of Technology Kharagpur,Department of Mechanical Engineering
[2] Indian Institute of Technology Kharagpur,School of Medical Science and Technology
关键词
Finite element analysis; Proximal femur; Total hip replacement; Bone remodelling; Bone orthotropy;
D O I
暂无
中图分类号
学科分类号
摘要
Peri-prosthetic bone adaptation has usually been predicted using subject-specific finite element analysis in combination with remodelling algorithms and assuming isotropic bone material property. The objective of the study is to develop an orthotropic bone remodelling algorithm for evaluation of peri-prosthetic bone adaptation in the uncemented implanted femur. The simulations considered loading conditions from a variety of daily activities. The orthotropic algorithm was tested on 2D and 3D models of the intact femur for verification of predicted results. The predicted orthotropic directionality, based on principal stress directions, was in agreement with the trabecular orientation in a micro-CT data of proximal femur. The validity of the proposed strain-based algorithm was assessed by comparing the predicted results of the orthotropic model with those of the strain-energy-density-based isotropic formulation. Despite agreement in cortical densities (R=0.71)\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(R = 0.71)$$\end{document}, the isotropic remodelling algorithm tends to predict relatively higher values around the distal tip of the implant as compared to the orthotropic model. Both formulations predicted 4–8% bone resorption in the proximal femur. A linear regression analysis revealed a significant correlation (R=0.99)\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(R = 0.99)$$\end{document} between the stresses and strains on the cortex of the proximal femur, predicted by the isotropic and orthotropic formulations. Despite reasonable agreement in peri-prosthetic bone density distributions, the quantitative differences with isotropic model predictions highlight the combined influences of bone orthotropy and mechanical stimulus in the adaptation process.
引用
收藏
页码:1115 / 1134
页数:19
相关论文
共 50 条
  • [31] Influence of interface condition and implant design on bone remodelling and failure risk for the resurfaced femoral head
    Rothstock, Stephan
    Uhlenbrock, Anne
    Bishop, Nicholas
    Laird, Lindsay
    Nassutt, Roman
    Morlock, Michael
    JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1646 - 1653
  • [32] Experimental and computational analysis of micromotions of an uncemented femoral knee implant using elastic and plastic bone material models
    Berahmani, Sanaz
    Janssen, Dennis
    Verdonschot, Nico
    JOURNAL OF BIOMECHANICS, 2017, 61 : 137 - 143
  • [33] Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss
    Rahmy, AIA
    Gosens, T
    Blake, GM
    Tonino, A
    Fogelman, I
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 (04) : 281 - 289
  • [34] Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss
    A. I. A. Rahmy
    T. Gosens
    G. M. Blake
    A. Tonino
    I. Fogelman
    Osteoporosis International, 2004, 15 : 281 - 289
  • [35] A Comparison of the Effects of Alendronate and Alfacalcidol on Bone Mineral Density Around the Femoral Implant and in the Lumbar Spine After Total Hip Arthroplasty
    Iwamoto, Naoyuki
    Inaba, Yutaka
    Kobayashi, Naomi
    Ishida, Takashi
    Yukizawa, Yohei
    Saito, Tomoyuki
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (13): : 1203 - 1209
  • [36] Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions
    Peng, L
    Bai, J
    Zeng, XL
    Zhou, YX
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (03) : 227 - 233
  • [37] Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions
    Baca, Vaclav
    Horak, Zdenek
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (08) : 935 - 935
  • [38] Significance of Orthotropic Material Models to Predict Stress Around Bone-Implant Interface Using Numerical Simulation
    Pankaj Dhatrak
    Vedant Girme
    Uddhav Shirsat
    S. Sumanth
    Vijay Deshmukh
    BioNanoScience, 2019, 9 : 652 - 659
  • [39] Significance of Orthotropic Material Models to Predict Stress Around Bone-Implant Interface Using Numerical Simulation
    Dhatrak, Pankaj
    Girme, Vedant
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    BIONANOSCIENCE, 2019, 9 (03) : 652 - 659
  • [40] Numerical evaluation of bone remodelling associated with trans-femoral osseointegration implant - A 68 month follow-up study
    Xu, D. H.
    Crocombe, A. D.
    Xu, W.
    JOURNAL OF BIOMECHANICS, 2016, 49 (03) : 488 - 492