Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation

被引:0
|
作者
Basil Mathai
Santanu Dhara
Sanjay Gupta
机构
[1] Indian Institute of Technology Kharagpur,Department of Mechanical Engineering
[2] Indian Institute of Technology Kharagpur,School of Medical Science and Technology
关键词
Finite element analysis; Proximal femur; Total hip replacement; Bone remodelling; Bone orthotropy;
D O I
暂无
中图分类号
学科分类号
摘要
Peri-prosthetic bone adaptation has usually been predicted using subject-specific finite element analysis in combination with remodelling algorithms and assuming isotropic bone material property. The objective of the study is to develop an orthotropic bone remodelling algorithm for evaluation of peri-prosthetic bone adaptation in the uncemented implanted femur. The simulations considered loading conditions from a variety of daily activities. The orthotropic algorithm was tested on 2D and 3D models of the intact femur for verification of predicted results. The predicted orthotropic directionality, based on principal stress directions, was in agreement with the trabecular orientation in a micro-CT data of proximal femur. The validity of the proposed strain-based algorithm was assessed by comparing the predicted results of the orthotropic model with those of the strain-energy-density-based isotropic formulation. Despite agreement in cortical densities (R=0.71)\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(R = 0.71)$$\end{document}, the isotropic remodelling algorithm tends to predict relatively higher values around the distal tip of the implant as compared to the orthotropic model. Both formulations predicted 4–8% bone resorption in the proximal femur. A linear regression analysis revealed a significant correlation (R=0.99)\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(R = 0.99)$$\end{document} between the stresses and strains on the cortex of the proximal femur, predicted by the isotropic and orthotropic formulations. Despite reasonable agreement in peri-prosthetic bone density distributions, the quantitative differences with isotropic model predictions highlight the combined influences of bone orthotropy and mechanical stimulus in the adaptation process.
引用
收藏
页码:1115 / 1134
页数:19
相关论文
共 50 条
  • [1] Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation
    Mathai, Basil
    Dhara, Santanu
    Gupta, Sanjay
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (03) : 1115 - 1134
  • [2] Orthotropic bone remodelling around uncemented femoral implant: a comparison with isotropic formulation
    Mathai, Basil
    Dhara, Santanu
    Gupta, Sanjay
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021,
  • [3] Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups
    Mulier, M.
    Jaecques, S. V. N.
    Raaijmaakers, M.
    Nijs, J.
    Van der Perre, G.
    Jonkers, I.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (07) : 941 - 948
  • [4] Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups
    M. Mulier
    S. V. N. Jaecques
    M. Raaijmaakers
    J. Nijs
    G. Van der Perre
    I. Jonkers
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 941 - 948
  • [5] Influence of ingrowth regions on bone remodelling around a cementless hip resurfacing femoral implant
    Haider, Ifaz T.
    Speirs, Andrew D.
    Beaule, Paul E.
    Frei, Hanspeter
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (12) : 1349 - 1357
  • [6] Bone remodelling around uncemented metallic and ceramic acetabular components
    Ghosh, Rajesh
    Mukherjee, Kaushik
    Gupta, Sanjay
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 490 - 502
  • [7] Mechanobiochemical bone remodelling around an uncemented acetabular component: influence of bone orthotropy
    Ceby Mullakkara Saviour
    Basil Mathai
    Sanjay Gupta
    Medical & Biological Engineering & Computing, 2024, 62 : 1717 - 1732
  • [8] Mechanobiochemical bone remodelling around an uncemented acetabular component: influence of bone orthotropy
    Saviour, Ceby Mullakkara
    Mathai, Basil
    Gupta, Sanjay
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (06) : 1717 - 1732
  • [9] Bone Ingrowth Around an Uncemented Femoral Implant Using Mechanoregulatory Algorithm: A Multiscale Finite Element Analysis
    Mathai, Basil
    Gupta, Sanjay
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (02):
  • [10] Measurement of early bone loss around an uncemented femoral stem
    Boe, Berte
    Heier, Tore
    Nordsletten, Lars
    ACTA ORTHOPAEDICA, 2011, 82 (03) : 321 - 324