A Monte Carlo evaluation of three Compton camera absorbers

被引:0
|
作者
C. Z. Uche
W. H. Round
M. J. Cree
机构
[1] University of Waikato,School of Engineering
来源
Australasian Physical & Engineering Sciences in Medicine | 2011年 / 34卷
关键词
Compton camera; Absorber; GEANT4; Detector parameters; Gamma rays;
D O I
暂无
中图分类号
学科分类号
摘要
We present a quantitative study on the performance of cadmium zinc telluride (CZT), thallium-doped sodium iodide (NaI(Tl)) and germanium (Ge) detectors as potential Compton camera absorbers. The GEANT4 toolkit was used to model the performance of these materials over the nuclear medicine energy range. CZT and Ge demonstrate the highest and lowest efficiencies respectively. Although the best spatial resolution was attained for Ge, its lowest ratio of single photoelectric to multiple interactions suggests that it is most prone to inter-pixel cross-talk. In contrast, CZT, which demonstrates the least positioning error due to multiple interactions, has a comparable spatial resolution with Ge. Therefore, we modelled a Compton camera system based on silicon (Si) and CZT as the scatterer and absorber respectively. The effects of the detector parameters of our proposed system on image resolution were evaluated and our results show good agreement with previous studies. Interestingly, spatial resolution which accounted for the least image degradation at 140.5 keV became the dominant degrading factor at 511 keV, indicating that the absorber parameters play some key roles at higher energies. The results of this study have validated the predictions by An et al. which state that the use of a higher energy gamma source together with reduction of the absorber segmentation to sub-millimetre could achieve the image resolution of 5 mm required in medical imaging.
引用
收藏
页码:351 / 360
页数:9
相关论文
共 50 条
  • [31] Monte Carlo Simulation of Massive Absorbers for Cryogenic Calorimeters
    D. Brandt
    M. Asai
    P. L. Brink
    B. Cabrera
    E. do Couto e Silva
    M. Kelsey
    S. W. Leman
    K. McArthy
    R. Resch
    D. Wright
    E. Figueroa-Feliciano
    Journal of Low Temperature Physics, 2012, 167 : 485 - 490
  • [32] Monte Carlo Simulation of Massive Absorbers for Cryogenic Calorimeters
    Brandt, D.
    Asai, M.
    Brink, P. L.
    Cabrera, B.
    do Couto e Silva, E.
    Kelsey, M.
    Leman, S. W.
    McArthy, K.
    Resch, R.
    Wright, D.
    Figueroa-Feliciano, E.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (3-4) : 485 - 490
  • [33] MONTE-CARLO SIMULATION FOR COMPTON SUPPRESSION SPECTROMETER
    TSOU, RH
    LIN, SC
    KIANG, LL
    COMPUTER PHYSICS COMMUNICATIONS, 1994, 83 (01) : 30 - 44
  • [34] Validation of Compton Scattering Monte Carlo Simulation Models
    Weidenspointner, Georg
    Batic, Matej
    Hauf, Steffen
    Hoff, Gabriela
    Kuster, Markus
    Pia, Maria Grazia
    Aracco, Paolo S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [35] 逆Compton散射的Monte Carlo模拟
    龙光波
    郑永刚
    欧建文
    王兴华
    黄霞
    王艳芳
    计算物理, 2016, 33 (02) : 136 - 146
  • [36] Monte Carlo PET Camera Modelling for Proton Range Evaluation in Proton Therapy
    Claire Van Ngoc Ty
    De Marzi, Ludovic
    Jan, Sebastien
    Lestand, Loic
    Ferrand, Regis
    Comtat, Claude
    Trebossen, Regine
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3501 - 3504
  • [37] PERFORMANCE EVALUATION OF THE UCL COMPTON CAMERA
    Alnaaimi, Mashari A.
    Royle, Gary J.
    Ghoggali, Walid
    Speller, Robert D.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1104 - 1107
  • [38] Energy-subtraction Compton scatter camera design considerations: A Monte Carlo study of timing and energy resolution effects
    Valentine, JD
    Bonnerave, C
    Rohe, RC
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1039 - 1043
  • [39] Energy-subtraction Compton scatter camera design considerations: A Monte Carlo study of timing and energy resolution effects
    Valentine, JD
    Bonnerave, C
    Rohe, RC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1134 - 1139
  • [40] Monte Carlo Simulation of Silicon (Si)/Cadmium Zinc Telluride (CZT) Material-based Compton Camera for Breast Cancer Detection: A Quantitative Evaluation Study
    Kang, Seong-Hyeon
    Lee, Youngjin
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 13 - 13