A Monte Carlo evaluation of three Compton camera absorbers

被引:0
|
作者
C. Z. Uche
W. H. Round
M. J. Cree
机构
[1] University of Waikato,School of Engineering
来源
Australasian Physical & Engineering Sciences in Medicine | 2011年 / 34卷
关键词
Compton camera; Absorber; GEANT4; Detector parameters; Gamma rays;
D O I
暂无
中图分类号
学科分类号
摘要
We present a quantitative study on the performance of cadmium zinc telluride (CZT), thallium-doped sodium iodide (NaI(Tl)) and germanium (Ge) detectors as potential Compton camera absorbers. The GEANT4 toolkit was used to model the performance of these materials over the nuclear medicine energy range. CZT and Ge demonstrate the highest and lowest efficiencies respectively. Although the best spatial resolution was attained for Ge, its lowest ratio of single photoelectric to multiple interactions suggests that it is most prone to inter-pixel cross-talk. In contrast, CZT, which demonstrates the least positioning error due to multiple interactions, has a comparable spatial resolution with Ge. Therefore, we modelled a Compton camera system based on silicon (Si) and CZT as the scatterer and absorber respectively. The effects of the detector parameters of our proposed system on image resolution were evaluated and our results show good agreement with previous studies. Interestingly, spatial resolution which accounted for the least image degradation at 140.5 keV became the dominant degrading factor at 511 keV, indicating that the absorber parameters play some key roles at higher energies. The results of this study have validated the predictions by An et al. which state that the use of a higher energy gamma source together with reduction of the absorber segmentation to sub-millimetre could achieve the image resolution of 5 mm required in medical imaging.
引用
收藏
页码:351 / 360
页数:9
相关论文
共 50 条
  • [21] VERSATILE COMPTON CAMERA FOR HIGH-ENERGY GAMMA RAYS: MONTE CARLO COMPARISON WITH ANGER CAMERA FOR MEDICAL IMAGING
    Fontana, M.
    Ley, J. -L.
    Testa, E.
    Letang, J. M.
    Maxim, V.
    Dauvergne, D.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1639 - 1645
  • [22] Preliminary evaluation of dual-head Compton camera with Si/CZT material for breast cancer detection: Monte Carlo simulation study
    Lee, Youngjin
    OPTIK, 2020, 202
  • [23] Unbiased Monte Carlo simulation of the compton profile
    Fernandez, J. E.
    Scot, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 209 - 213
  • [24] Optimization and Estimation of Parameters for a Compton Camera Consisting of the DSSD Scatterer and the GAGG Absorber with the Monte Carlo Simulation
    Lee, Jong Hun
    Jang, Taek Jin
    Lee, Il Maek
    Lee, Chun Sik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (12) : 1113 - 1117
  • [25] Optimization and Estimation of Parameters for a Compton Camera Consisting of the DSSD Scatterer and the GAGG Absorber with the Monte Carlo Simulation
    Jong Hun Lee
    Taek Jin Jang
    Il Maek Lee
    Chun Sik Lee
    Journal of the Korean Physical Society, 2020, 77 : 1113 - 1117
  • [26] Optimal design of Anger camera for bremsstrahlung imaging: Monte Carlo evaluation
    Walrand, Stephan
    Hesse, Michel
    Wojcik, Randy
    Lhommel, Renaud
    Jamar, Francois
    FRONTIERS IN ONCOLOGY, 2014, 4
  • [27] Monte Carlo evaluation of a BGO-pinhole dedicated bremsstrahlung camera
    Hesse, M.
    Walrand, S.
    Demonceau, G.
    Lhommel, R.
    Jamar, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S307 - S307
  • [28] Performance Evaluation of Compton Micro-PET for Detector Modalities: A Monte Carlo Study
    Yoon, Changyeon
    Lee, Wonho
    NUCLEAR TECHNOLOGY, 2018, 204 (03) : 386 - 395
  • [29] Monitoring of Dose Distribution in Photon Therapy With Multiple-Scattering Compton Camera: A Monte Carlo Simulation Study
    Lee, Taewoong
    Lee, Hyounggun
    Lee, Wonho
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (06) : 2801 - 2806
  • [30] Design of a new Compton Camera by Monte Carlo method and assessment its important parameters affecting image quality
    Karimian, A.
    Jia, B.
    Raisali, G.
    Rahimi, F.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 414 - 416