H*(10) and neutron spectra around linacs

被引:0
|
作者
Hector Rene Vega-Carrillo
Arturo Ortíz-Hernandez
Victor Martin Hernandez-Davila
Berenice Hernández-Almaraz
Teodoro Rivera Montalvo
机构
[1] Unidad Academica de Estudios Nucleares de la Universidad Autonoma de Zacatecas,
[2] CICATA-IPN Unidad Legaria,undefined
关键词
Photoneutrons; Neutron spectra; Dose; Bonner sphere spectrometer;
D O I
暂无
中图分类号
学科分类号
摘要
Neutron spectrum and ambient dose equivalent has been measured around two 10 MV linear accelerators. Measurements were carried out in Mevatron and Primus model linacs, both made by Siemens. Main differences between those models are the beam collimator and the vault room. Here, Bonner sphere spectrometer with a passive thermal neutron detector has been utilized to measure the neutron spectrum inside the vault. Using an active detector the neutron spectrum was measured at the vault’s door of both accelerators. With a neutron area monitor the dose equivalent was measured by the door at both vault doors. Neutron strength, total fluence rate and ambient dose equivalent were compared, from this was found that shielding conditions are better in the Primus model.
引用
收藏
页码:537 / 540
页数:3
相关论文
共 50 条
  • [11] Neutron imaging using medical linacs
    Adnani, N
    Fallone, BG
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2457 - 2460
  • [12] The effects of shielding around the source on neutron energy spectra
    Pehlivanovic, B.
    Marinkovic, P.
    Avdic, S.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2011, 166 (12): : 901 - 907
  • [13] Neutron spectra and H*(10) of photoneutrons inside the vault room of an 18 MV LINAC
    Banuelos-Frias, A.
    Borja-Hernandez, C. G.
    Guzman-Garcia, K. A.
    Valero-Luna, C.
    Hernandez-Davila, V. M.
    Vega-Carrillo, H. R.
    REVISTA MEXICANA DE FISICA, 2012, 58 (03) : 192 - 194
  • [14] Emission spectra of fallback disks around young neutron stars
    Perna, R
    Hernquist, L
    Narayan, R
    ASTROPHYSICAL JOURNAL, 2000, 541 (01): : 344 - 350
  • [15] FUNCTIONAL FORMS FOR PHOTON SPECTRA OF CLINICAL LINACS
    Ali, E.
    Rogers, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S149 - S149
  • [16] Functional forms for photon spectra of clinical linacs
    Ali, E. S. M.
    Rogers, D. W. O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 31 - 50
  • [17] General relativistic spectra of accretion disks around rotating neutron stars
    Bhattacharyya, S
    Misra, R
    Thampan, AV
    ASTROPHYSICAL JOURNAL, 2001, 550 (02): : 841 - 845
  • [18] Neutron spectra and dosimetric features around an 18 MV Linac accelerator
    Barquero, R
    Mendez, R
    Vega-Carrillo, HR
    Iñiguez, MP
    Edwards, TM
    HEALTH PHYSICS, 2005, 88 (01): : 48 - 58
  • [19] Ambient neutron and photon dose equivalent H*(10) around a pencil beam scanning proton therapy facility
    Sharma, Dayananda Shamurailatpam
    Patro, Kartikeswar C. H.
    Padannayel, Noufal Manthala
    Arjunan, Manikandan
    Krishnan, Ganapathy
    Thiyagarajan, Rajesh
    Chilukuri, Srinivas
    Jalali, Rakesh
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1102):
  • [20] COMPARISON OF NEUTRON MEASUREMENTS AT LINACS USING BUBBLE DOSIMETERS TO OTHER NEUTRON DETECTORS
    NELSON, ME
    GORDON, R
    RADIATION PROTECTION DOSIMETRY, 1993, 47 (1-4) : 547 - 550