Neutron imaging using medical linacs

被引:0
|
作者
Adnani, N [1 ]
Fallone, BG [1 ]
机构
[1] Cross Canc Inst, Edmonton, AB T6G 1Z2, Canada
关键词
neutrons; linacs; thermal neutron radiography; fast neutron radiography;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The feasibility of imaging soft tissues with neutrons (neutron radiography) from a medical linac as a complement to the conventional x-ray portal imaging is proven. Both direct and indirect neutron radiographs have been successfully obtained. In the direct method, a film is exposed to the beam through a neutron converter, The latter transforms the neutrons into gamma -rays which subsequently darken the film, In the indirect method, a metallic foil is exposed to the neutrons in the beam and subsequently becomes activated. The resulting gamma rays from the decay of the activation reaction are subsequently used to darken a film and produce an image. In addition, because most of the neutrons generated are fast (average 1 to 2 MeV), a fast neutron radiograph has also been successfully obtained using a CR-39 plate. An exit dosimetry method is suggested for boron neutron capture therapy (BNCT) using neutron radiography, In this manner, the concentration distribution of boron-10 and/or the neutron capture dose in the irradiated region can be obtained through proper calibration. Possible clinical applications of neutron radiography with medical linacs are discussed.
引用
收藏
页码:2457 / 2460
页数:4
相关论文
共 50 条
  • [1] Neutron therapy using medical linacs
    Adnani, N
    Fallone, BG
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 133 - 136
  • [2] USE OF A NEUTRON REMMETER TO MEASURE LEAKAGE NEUTRONS FROM MEDICAL LINACS
    ROGERS, DWO
    VANDYK, G
    MEDICAL PHYSICS, 1980, 7 (04) : 426 - 426
  • [3] MEASUREMENTS OF THE PARASITIC NEUTRON DOSE AT ORGANS FROM MEDICAL LINACS AT DIFFERENT ENERGIES BY USING BUBBLE DETECTORS
    Alikaniotis, K.
    Severgnini, M.
    Giannini, G.
    Milan, V.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 267 - 272
  • [4] COMPARISON OF NEUTRON MEASUREMENTS AT LINACS USING BUBBLE DOSIMETERS TO OTHER NEUTRON DETECTORS
    NELSON, ME
    GORDON, R
    RADIATION PROTECTION DOSIMETRY, 1993, 47 (1-4) : 547 - 550
  • [5] Neutron and photon spectra in LINACs
    Vega-Carrillo, H. R.
    Martinez-Ovalle, S. A.
    Lallena, A. M.
    Mercado, G. A.
    Benites-Rengifo, J. L.
    APPLIED RADIATION AND ISOTOPES, 2012, 71 : 75 - 80
  • [6] New medical linacs
    Schonberg, RG
    Mishin, AV
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY - PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE, PTS 1 AND 2, 1997, (392): : 1289 - 1292
  • [7] Active neutron monitor for radiotherapy linacs
    Gomez, F.
    Brualla, L.
    Gonzalez-Castano, D. M.
    Guerre, F. X.
    Gutierrez, F.
    Iglesias, A.
    Pazos, A.
    Pena, J.
    Pombar, M.
    Rosello, J. V.
    Zapata, M.
    Sanchez-Doblado, F.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S255 - S255
  • [8] Linacs for Medical Isotope Production
    Pramudita, A.
    ATOM INDONESIA, 2011, 37 (01) : 1 - 4
  • [9] Medical applications of electron linacs
    Wambersie, A
    Gahbauer, RA
    PROCEEEDINGS OF THE XVIII INTERNATIONAL LINEAR ACCELERATOR CONFERENCE, VOLS 1 AND 2, 1996, 96 (07): : 610 - 610
  • [10] H*(10) and neutron spectra around linacs
    Hector Rene Vega-Carrillo
    Arturo Ortíz-Hernandez
    Victor Martin Hernandez-Davila
    Berenice Hernández-Almaraz
    Teodoro Rivera Montalvo
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 283 : 537 - 540