Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode

被引:0
|
作者
B. Muralidharan
G. Gopu
C. Vedhi
P. Manisankar
机构
[1] Birla Institute of Technology and Science-Pilani,Department of Chemistry
[2] Alagappa University,Department of Industrial Chemistry
[3] V.O. Chidambaram College,Department of Chemistry
来源
关键词
Acetaminophen; Acetylsalicylic acid; Dipyrone; Nano polypyrrole; Voltammetry; Stripping voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
Three analgesics (acetaminophen, acetylsalicylic acid, and dipyrone) were determined electrochemically using nano polypyrrole modified glassy carbon electrode. The cyclic voltammetric behavior of the three analgesics was studied in aqueous acid, neutral, and alkaline conditions. One well-defined oxidation peak each for acetaminophen and acetylsalicylic acid and three oxidation peaks for dipyrone were observed in the cyclic voltammograms. The influence of pH, scan rate, and concentration reveal the irreversible diffusion controlled loss of 4e− in acid and neutral media and 2e−/1H+ in basic medium for acetaminophen. In the case of acetylsalicylic acid, 2e− and 1H+ loss in acidic and neutral pH and 2e− and 2H+ loss in basic pH were observed and the oxidation was irreversible and controlled by adsorption. Irreversible removal of 2e− and 1H+ in all pH media was observed for dipyrone and the oxidation was controlled by diffusion. A systematic study of the experimental parameters that affect the differential pulse stripping voltammetric response was carried out and optimized conditions which yield maximum peak current were arrived at. Scanning electron microscopy (SEM) analysis confirms good accumulation of the drugs on the electrode surface. The calibration was made under optimum conditions. The range of study for acetaminophen, acetylsalicylic acid, and dipyrone was 50–250, 40–300, and 100–400 ng/mL and the lower limit of determination was 45, 25, and 70 ng/mL respectively. The suitability of the method for the determination of the three analgesics in pharmaceutical preparations and urine samples was also ascertained.
引用
收藏
页码:1177 / 1184
页数:7
相关论文
共 50 条
  • [1] Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode
    Muralidharan, B.
    Gopu, G.
    Vedhi, C.
    Manisankar, P.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (08) : 1177 - 1184
  • [2] Electrochemical determination of sparfloxacin in pharmaceutical formulations and urine samples using a β-cyclodextrin modified carbon paste electrode
    Reddy, TM
    Sreedhar, M
    Reddy, SJ
    ANALYTICAL LETTERS, 2003, 36 (07) : 1365 - 1379
  • [3] Voltammetric determination of bisoprolol fumarate in pharmaceutical formulations and urine using single-wall carbon nanotubes modified glassy carbon electrode
    Goyal, Rajendra N.
    Tyagi, Anuradha
    Bachheti, Neeta
    Bishnoi, Sunita
    ELECTROCHIMICA ACTA, 2008, 53 (06) : 2802 - 2808
  • [4] Batch injection analysis with amperometric detection for fluoroquinolone determination in urine, pharmaceutical formulations, and milk samples using a reduced graphene oxide–modified glassy carbon electrode
    Lucas Vinícius de Faria
    Davi Marques de Farias
    Thalles Pedrosa Lisboa
    Maria Auxiliadora Costa Matos
    Rodrigo Alejandro Abarza Munoz
    Renato Camargo Matos
    Analytical and Bioanalytical Chemistry, 2022, 414 : 5309 - 5318
  • [5] Stripping Voltammetric Determination of Analgesics in Their Pharmaceuticals Using Nano-Riboflavin-Modified Glassy Carbon Electrode
    Gopu, Gopalakrishnan
    Manisankar, Paramasivam
    Muralidharan, Baladhandapani
    Vedhi, Chinnapiyan
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2011, 2011
  • [6] Simple and Fast Determination of Piroxicam in Pharmaceutical and Real Samples Using Glassy Carbon Electrode Modified with Copper Nano-particles
    Feizollahi, Azizallah
    Rafati, Amir Abbas
    Assari, Parnaz
    Joghani, Roghayeh Asadpour
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (06)
  • [7] Batch injection analysis with amperometric detection for fluoroquinolone determination in urine, pharmaceutical formulations, and milk samples using a reduced graphene oxide-modified glassy carbon electrode
    de Faria, Lucas Vinicius
    de Farias, Davi Marques
    Lisboa, Thalles Pedrosa
    Matos, Maria Auxiliadora Costa
    Munoz, Rodrigo Alejandro Abarza
    Matos, Renato Camargo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (18) : 5309 - 5318
  • [8] Graphene layer modified glassy carbon electrode for the determination of norepinephrine and theophylline in pharmaceutical formulations
    Raj, M. Amal
    John, S. Abraham
    ANALYTICAL METHODS, 2014, 6 (07) : 2181 - 2188
  • [9] A New Approach on Sensitive Assay of Adefovir in Pharmaceutical and Biological Fluid Samples Using Polypyrrole Modified Glassy Carbon Electrode
    Zaabal, Moufida
    Bakirhan, Nurgul K.
    Doulache, Merzak
    Kaddour, Samia
    Saidat, Boubakeur
    Ozkan, Sibel A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 323 (323):
  • [10] Sensitive and selective electrochemical determination of doxycycline in pharmaceutical formulations using poly(dipicrylamine) modified glassy carbon electrode
    Gashu, Mulu
    Kassa, Adane
    Tefera, Molla
    Amare, Meareg
    Aragaw, Belete Asefa
    SENSING AND BIO-SENSING RESEARCH, 2022, 37