Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode

被引:0
|
作者
B. Muralidharan
G. Gopu
C. Vedhi
P. Manisankar
机构
[1] Birla Institute of Technology and Science-Pilani,Department of Chemistry
[2] Alagappa University,Department of Industrial Chemistry
[3] V.O. Chidambaram College,Department of Chemistry
来源
关键词
Acetaminophen; Acetylsalicylic acid; Dipyrone; Nano polypyrrole; Voltammetry; Stripping voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
Three analgesics (acetaminophen, acetylsalicylic acid, and dipyrone) were determined electrochemically using nano polypyrrole modified glassy carbon electrode. The cyclic voltammetric behavior of the three analgesics was studied in aqueous acid, neutral, and alkaline conditions. One well-defined oxidation peak each for acetaminophen and acetylsalicylic acid and three oxidation peaks for dipyrone were observed in the cyclic voltammograms. The influence of pH, scan rate, and concentration reveal the irreversible diffusion controlled loss of 4e− in acid and neutral media and 2e−/1H+ in basic medium for acetaminophen. In the case of acetylsalicylic acid, 2e− and 1H+ loss in acidic and neutral pH and 2e− and 2H+ loss in basic pH were observed and the oxidation was irreversible and controlled by adsorption. Irreversible removal of 2e− and 1H+ in all pH media was observed for dipyrone and the oxidation was controlled by diffusion. A systematic study of the experimental parameters that affect the differential pulse stripping voltammetric response was carried out and optimized conditions which yield maximum peak current were arrived at. Scanning electron microscopy (SEM) analysis confirms good accumulation of the drugs on the electrode surface. The calibration was made under optimum conditions. The range of study for acetaminophen, acetylsalicylic acid, and dipyrone was 50–250, 40–300, and 100–400 ng/mL and the lower limit of determination was 45, 25, and 70 ng/mL respectively. The suitability of the method for the determination of the three analgesics in pharmaceutical preparations and urine samples was also ascertained.
引用
收藏
页码:1177 / 1184
页数:7
相关论文
共 50 条
  • [41] Synthesis and Characterization of Poly (3-hexylthiophene) and Used as Modified Electrode for Determination of Antidepressants in Pharmaceutical Formulations and Urine Samples
    Lakshmi, A.
    Vedhi, C.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : H252 - H257
  • [42] Electrochemical determination of tartaric acid at nano gold/nano carbon modified glassy carbon electrode
    Yang Song
    Yuanzhi Song
    Jiang Xu
    Russian Journal of Physical Chemistry A, 2012, 86 : 1458 - 1464
  • [43] Electrochemical determination of tartaric acid at nano gold/nano carbon modified glassy carbon electrode
    Song, Yang
    Song, Yuanzhi
    Xu, Jiang
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2012, 86 (09) : 1458 - 1464
  • [44] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [45] Spectrophotometric determination of sparfloxacin in pharmaceutical formulations and urine samples
    Jan, M. R.
    Shah, J.
    Inayatullah
    JOURNAL OF APPLIED SPECTROSCOPY, 2010, 77 (03) : 400 - 405
  • [46] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378
  • [47] Spectrophotometric determination of sparfloxacin in pharmaceutical formulations and urine samples
    M. R. Jan
    J. Shah
      Inayatullah
    Journal of Applied Spectroscopy, 2010, 77 : 400 - 405
  • [48] Electrochemical determination of ascorbic acid and paracetamol in pharmaceutical formulations using a glassy carbon electrode modified with multi-wall carbon nanotubes dispersed in polyhistidine
    Dalmasso, Pablo R.
    Pedano, Maria L.
    Rivas, Gustavo A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 732 - 736
  • [49] Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode
    Le Thi Thanh Nhi
    Nguyen Thi Thanh Tu
    Le Thi Hoa
    Tran Thanh Tam Toan
    Le Van Thanh Son
    Nguyen Van Hung
    Tran Ngoc Tuyen
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2021, 23
  • [50] Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode
    Nhi, Le Thi Thanh
    Tu, Nguyen Thi Thanh
    Hoa, Le Thi
    Toan, Tran Thanh Tam
    Van Thanh Son, Le
    Van Hung, Nguyen
    Tuyen, Tran Ngoc
    Khieu, Dinh Quang
    JOURNAL OF NANOPARTICLE RESEARCH, 2021, 23 (10)