Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment

被引:0
|
作者
Mohammad Mahfujur Rahman
Chan Hyeong Kim
Seonghoon Kim
机构
[1] Hanyang University,Department of Nuclear Engineering
[2] Hanyang University Medical Center,Department of Radiation Oncology
来源
关键词
RapidArc; MLC; Quality assurance; Portal dosimetry; Dynalog files;
D O I
暂无
中图分类号
学科分类号
摘要
Volumetric modulated arc therapy (VMAT) with highly complex advanced delivering technique, is widely practiced in radiation therapy and requires a quality assurance for treatment plan at least once a treatment session. In this study we collected six VMAT patients with different treatment sites. The VMAT plans and their quality assurance (QA) plans were performed on a daily basis before treatment for their full period of treatment. We tried to evaluate the accuracy of their delivering through analyses of first mechanical error of multileaf collimator (MLC) movement and second dosimetric error of beam delivery. We used a MATLAB program and portal dosimetry to estimate a maximum root mean square (RMS) error from dynalog files for mechanical analysis and a gamma index from portal dosimetry for dosimetric analysis, respectively. We introduced newly in this study a representative VMAT QA to be used to perform a routine VMAT QA. The daily variation of maximum error RMSs for all treatment sites were all below maximum 0.3503 ± 0.0002 mm for treatment plans and QA plans and they all showed the gamma pass rate of more than 98%. Mean of inter difference between treatment and QA plans stayed below 0.04 mm, showing that QA deliveries agree well with treatment deliveries. The Linac used kept a good performance within the tolerances in American Association of Physicists in Medicine (AAPM) TG142 guideline for the period of research. We suggest that the representative VMAT QA can be a good surrogate for real VMAT plan and “whole time” plan QA for a patient selected randomly at least once a year be performed to confirm the long-term stability of Linac performance.
引用
收藏
页码:990 / 1000
页数:10
相关论文
共 50 条
  • [1] Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment
    Rahman, Mohammad Mahfujur
    Kim, Chan Hyeong
    Kim, Seonghoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (07) : 990 - 1000
  • [2] Evidence based quality assurance of volumetric modulated arc therapy
    Tuemmler, H.
    Bellmann, C.
    Schilling, P.
    Schreiber, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S117 - S117
  • [3] EPID-BASED QUALITY ASSURANCE FOR VOLUMETRIC MODULATED ARC THERAPY
    Hoffmann, L.
    Jorgensen, M. B. Kyed
    Petersen, J.
    Praestegaard, L. H.
    Hansen, R.
    Muren, L. P.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S82 - S83
  • [4] Multileaf Collimator Quality Assurance for Volumetric Modulated Arc Therapy
    Lin, T.
    Hossain, M.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3598 - U31
  • [5] Quality assurance of dynamic parameters in volumetric modulated arc therapy
    Manikandan, A.
    Sarkar, B.
    Holla, R.
    Vivek, T. R.
    Sujatha, N.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015): : 1002 - 1010
  • [6] Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy
    Letourneau, Daniel
    Publicover, Julia
    Kozelka, Jakub
    Moseley, Douglas J.
    Jaffray, David A.
    MEDICAL PHYSICS, 2009, 36 (05) : 1813 - 1821
  • [7] Geometric and Dosimetric Quality Assurance in Volumetric Modulated Arc Therapy (VMAT)
    Qian, J.
    Ma, Y.
    Lee, L.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S639 - S639
  • [8] Quality assurance of volumetric modulated arc therapy using Elekta Synergy
    Haga, Akihiro
    Nakagawa, Keiichi
    Shiraishi, Kenshiro
    Itoh, Saori
    Terahara, Atsuro
    Yamashita, Hideomi
    Ohtomo, Kuni
    Saegusa, Shigeki
    Imae, Toshikazu
    Yoda, Kiyoshi
    Pellegrini, Roberto
    ACTA ONCOLOGICA, 2009, 48 (08) : 1193 - 1197
  • [9] Daily Quality Assurance of Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy Using Dynamic Log Files: Retrospective Study
    Tachibana, H.
    Luxton, G.
    Xing, L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Neural Network Model Based on Branch Architecture for the Quality Assurance of Volumetric Modulated Arc Therapy
    Xie, Lizhang
    Zhang, Lei
    Hu, Ting
    Li, Guangjun
    Yi, Zhang
    BIOENGINEERING-BASEL, 2024, 11 (04):