Mitigating the seismic pounding of multi-story buildings in series using linear and nonlinear fluid viscous dampers

被引:20
|
作者
Elwardany, Hytham [1 ]
Jankowski, Robert [2 ]
Seleemah, Ayman [3 ]
机构
[1] Delta Univ Sci & Technol, Fac Engn, Struct Engn Dept, Belkas, Egypt
[2] Gdansk Univ Technol, Fac Civil & Environm Engn, Gdansk, Poland
[3] Tanta Univ, Fac Engn, Struct Engn Dept, Tanta, Egypt
关键词
Series of structures; Structural pounding; Linear fluid viscous dampers; Nonlinear fluid viscous dampers; Earthquakes; Contact surfaces; ADJACENT BUILDINGS; DYNAMICS; BEHAVIOR; DAMAGE; MODEL; SLIP;
D O I
10.1007/s43452-021-00249-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic-induced pounding between adjacent buildings may have serious consequences, ranging from minor damage up to total collapse. Therefore, researchers try to mitigate the pounding problem using different methods, such as coupling the adjacent buildings with stiff beams, connecting them using viscoelastic links, and installing damping devices in each building individually. In the current paper, the effect of using linear and nonlinear fluid viscous dampers to mitigate the mutual pounding between a series of structures is investigated. Nonlinear finite-element analysis of a series of adjacent steel buildings equipped with damping devices was conducted. Contact surfaces with both contactor and target were used to model the mutual pounding. The results indicate that the use of linear or nonlinear dampers leads to the significant reduction in the response of adjacent buildings in series. Moreover, the substantial improvement of the performance of buildings has been observed for almost all stories. From the design point of view, it is concluded that dampers implemented in adjacent buildings should be designed to resist maximum force of 6.20 or 1.90 times the design independent force in the case of using linear or nonlinear fluid viscous dampers, respectively. Also, designers should pay attention to the design of the structural elements surrounding dampers, because considerable forces due to pounding may occur in the dampers at the maximum displaced position of the structure.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Improving total-building seismic performance using linear fluid viscous dampers
    Del Gobbo, Giuseppe Marcantonio
    Blakeborough, Anthony
    Williams, Martin S.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (09) : 4249 - 4272
  • [32] Improving total-building seismic performance using linear fluid viscous dampers
    Giuseppe Marcantonio Del Gobbo
    Anthony Blakeborough
    Martin S. Williams
    Bulletin of Earthquake Engineering, 2018, 16 : 4249 - 4272
  • [33] A displacement-based seismic design procedure for buildings with fluid viscous dampers
    Banuelos-Garcia, Francisco H.
    Ayala, Gustavo
    Lopez, Saul
    EARTHQUAKES AND STRUCTURES, 2020, 18 (05) : 609 - 623
  • [34] Stochastic seismic response analysis of adjacent buildings coupled by nonlinear viscous dampers
    Tubaldi, E.
    Barbato, M.
    Dall'Asta, A.
    EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 2861 - 2868
  • [35] Seismic performance of buildings retrofitted with nonlinear viscous dampers and adjacent reaction towers
    Impollonia, Nicola
    Palmeri, Alessandro
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (05): : 1329 - 1351
  • [36] Simplified estimation method of inelastic seismic demands of buildings with seesaw system using fluid viscous dampers
    Kang, Jae-Do
    Mori, Yasuhiro
    ENGINEERING STRUCTURES, 2017, 138 : 120 - 130
  • [37] Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers
    Yu-Yuan Lin
    Kuo-Chun Chang
    Chang-Yu Chen
    Bulletin of Earthquake Engineering, 2008, 6 : 535 - 552
  • [38] Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers
    Lin, Yu-Yuan
    Chang, Kuo-Chun
    Chen, Chang-Yu
    BULLETIN OF EARTHQUAKE ENGINEERING, 2008, 6 (03) : 535 - 552
  • [39] Seismic Vulnerability Assessment of Existing Multi-Story Reinforced Concrete Buildings in Egypt
    Said A. El-Kholy
    Mohamed S. El-Assaly
    Medhat Maher
    Arabian Journal for Science and Engineering, 2012, 37 : 341 - 355
  • [40] Effect of infill walls on seismic performance of multi-story buildings with shear walls
    Guettala S.
    Khelaifia A.
    Chebili R.
    Guettala S.
    Asian Journal of Civil Engineering, 2024, 25 (5) : 3989 - 3999