Mitigating the seismic pounding of multi-story buildings in series using linear and nonlinear fluid viscous dampers

被引:20
|
作者
Elwardany, Hytham [1 ]
Jankowski, Robert [2 ]
Seleemah, Ayman [3 ]
机构
[1] Delta Univ Sci & Technol, Fac Engn, Struct Engn Dept, Belkas, Egypt
[2] Gdansk Univ Technol, Fac Civil & Environm Engn, Gdansk, Poland
[3] Tanta Univ, Fac Engn, Struct Engn Dept, Tanta, Egypt
关键词
Series of structures; Structural pounding; Linear fluid viscous dampers; Nonlinear fluid viscous dampers; Earthquakes; Contact surfaces; ADJACENT BUILDINGS; DYNAMICS; BEHAVIOR; DAMAGE; MODEL; SLIP;
D O I
10.1007/s43452-021-00249-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic-induced pounding between adjacent buildings may have serious consequences, ranging from minor damage up to total collapse. Therefore, researchers try to mitigate the pounding problem using different methods, such as coupling the adjacent buildings with stiff beams, connecting them using viscoelastic links, and installing damping devices in each building individually. In the current paper, the effect of using linear and nonlinear fluid viscous dampers to mitigate the mutual pounding between a series of structures is investigated. Nonlinear finite-element analysis of a series of adjacent steel buildings equipped with damping devices was conducted. Contact surfaces with both contactor and target were used to model the mutual pounding. The results indicate that the use of linear or nonlinear dampers leads to the significant reduction in the response of adjacent buildings in series. Moreover, the substantial improvement of the performance of buildings has been observed for almost all stories. From the design point of view, it is concluded that dampers implemented in adjacent buildings should be designed to resist maximum force of 6.20 or 1.90 times the design independent force in the case of using linear or nonlinear fluid viscous dampers, respectively. Also, designers should pay attention to the design of the structural elements surrounding dampers, because considerable forces due to pounding may occur in the dampers at the maximum displaced position of the structure.
引用
收藏
页数:16
相关论文
共 50 条
  • [11] Influence of Higher Modes of Vibration on the Seismic Response of Buildings with Linear and Nonlinear Viscous Dampers
    Santos-Santiago, Marco A.
    Ruiz, Sonia E.
    Valenzuela-Beltran, Federico
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (08) : 3914 - 3937
  • [12] Unsymmetricity effects on seismic performance of multi-story buildings
    Pandian, Antony Vimal Paul
    Arunachalam, Krishna Prakash
    Bahrami, Alireza
    Romero, Lenin Miguel Bendezu
    Avudaiappan, Siva
    Awoyera, Paul O.
    DISCOVER APPLIED SCIENCES, 2024, 6 (09)
  • [13] Seismic performance of multi-story modular box buildings
    Feng, Ruoqiang
    Shen, Liu
    Yun, Qiu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 168 (168)
  • [14] New directions in seismic monitoring of multi-story buildings
    Safak, E
    STRUCTURAL HEALT H MONITORING: CURRENT STATUS AND PERSPECTIVES, 1997, : 418 - 429
  • [15] A methodology of design for seismic performance enhancement of buildings using viscous fluid dampers
    Raju, K. Rama
    Ansu, M.
    Iyer, Nagesh R.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (03): : 342 - 355
  • [16] Effect of seismic torsional component on nonlinear behavior of reinforced concrete multi-story buildings
    Ouazir, Abderrahmane
    Hadjadj, Asma
    Ouazir, Mansour
    Boukendakji, Mustapha
    Gasmi, Hatem
    STRUCTURAL ENGINEERING AND MECHANICS, 2024, 91 (04) : 349 - 355
  • [17] Seismic design of structure with nonlinear fluid viscous dampers
    Li, B.
    Liang, X. W.
    Ye, Y. X.
    ISISS '2007: PROCEEDINGS OF THE INNOVATION AND SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2008, : 1428 - 1439
  • [18] Seismic response control design procedure of R/C multi-story asymmetric buildings using visco-elastic dampers
    Fujii, Kenji
    Journal of Structural and Construction Engineering, 2008, 73 (634): : 2195 - 2204
  • [19] Influence of nonlinear fluid viscous dampers in controlling the seismic response of the base-isolated buildings
    Deringol, Ahmet Hilmi
    Guneyisi, Esra Mete
    STRUCTURES, 2021, 34 : 1923 - 1941
  • [20] Performance-based seismic risk assessment for buildings equipped with linear and nonlinear viscous dampers
    Tubaldi, E.
    Barbato, M.
    Dall'Asta, A.
    ENGINEERING STRUCTURES, 2014, 78 : 90 - 99