Uncertainty Estimation in PM10 Mass Measurements

被引:0
|
作者
Jyoti Pokhariyal
Anubha Mandal
Shankar G. Aggarwal
机构
[1] CSIR-National Physical Laboratory,
[2] Delhi Technological University,undefined
来源
MAPAN | 2019年 / 34卷
关键词
PM; NAAQS; Measurement uncertainty; PM;
D O I
暂无
中图分类号
学科分类号
摘要
Mass measurements of particles in the atmosphere are important for regulatory and scientific purposes. In nearly all of the countries, particulates ≤ 10 µm in aerodynamic size (PM10) are one of the most significant parameters of National Ambient Air Quality Standards (NAAQS). In India, as given in NAAQS, the PM10 regulatory limit is 60 µg m−3 which is based on the annual mean weight of samples (minimum 104) annually at a specific site taken for two/three days in a week for 24 h. In this paper, the components of uncertainty involved in the filter-based sampling of PM10 along with the gravimetric determination of mass have been calculated. As per the EPA guidelines, PM10 mass was monitored for a year at NPL (National Physical Laboratory), New Delhi from January 2014 to January 2015. The 24-h time-weighted mean mass concentration (n = 104) for one-year measurement varied from 32.5 to 480.2 µg m−3.During the study, high mass loading was observed in the month of December to February. In general, the flow rate of the sampling has been reported to be major uncertainty component in size-segregated PM sampling. In this work, the flow rate of the sampling (90.4%) and charge effect of the filter (6.7%) had the major contribution in the total uncertainty budget of PM10 mass measurement. Rest of the uncertainty components, e.g., balances (0.39%) and conditioning of filter (2.39%), had the least contribution.
引用
收藏
页码:129 / 133
页数:4
相关论文
共 50 条
  • [41] Characterization of PM2.5 Mass in Relation to PM1.0 and PM10 in Megacity Seoul
    Jihyun Han
    Seahee Lim
    Meehye Lee
    Young Jae Lee
    Gangwoong Lee
    Changsub Shim
    Lim-Seok Chang
    Asian Journal of Atmospheric Environment, 16 (1)
  • [42] Characterization of PM2.5 Mass in Relation to PM1.0 and PM10 in Megacity Seoul
    Han, Jihyun
    Lim, Seahee
    Lee, Meehye
    Lee, Young Jae
    Lee, Gangwoong
    Shim, Changsub
    Chang, Lim-Seok
    ASIAN JOURNAL OF ATMOSPHERIC ENVIRONMENT, 2022, 16 (01)
  • [43] Positive bias caused by residual water in reference PM10 measurements
    Imre, Kornelia
    Molnar, Agnes
    Dezsi, Viktor
    Geleneser, Andras
    IDOJARAS, 2014, 118 (03): : 207 - 216
  • [44] Elemental composition and cytotoxic effects of indoor PM10 compared to outdoor PM10
    Ceder, S.
    Weichenmeier, I
    Schober, W.
    Dietrich, S.
    Fromme, H.
    Behrendt, H.
    Buters, J. T. M.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2009, 379 : 68 - 68
  • [45] Estimation of PM2.5 and PM10 Mass Concentrations in Beijing Using Gaofen-1 Data at 100 m Resolution
    Wu, Shuhui
    Sun, Yuxin
    Bai, Rui
    Jiang, Xingxing
    Jin, Chunlin
    Xue, Yong
    REMOTE SENSING, 2024, 16 (04)
  • [46] The correction of TEOM PM10 measurements at different monitoring sites and climates
    Pucer, Jana Faganeli
    SN APPLIED SCIENCES, 2019, 1 (10):
  • [47] Orientated PM10 measurements with a high volume sampler in a turkey barn
    Schutz, A
    Seedorf, J
    Klasmeier, E
    Hartung, J
    Environmental Exposure and Health, 2005, 85 : 81 - 88
  • [48] PM10 and heavy metal measurements in an industrial area of southern Italy
    Ragosta, Maria
    Caggiano, Rosa
    D'Emilio, Mariagrazia
    Sabia, Serena
    Trippetta, Serena
    Macchiato, Maria
    ATMOSPHERIC RESEARCH, 2006, 81 (04) : 304 - 319
  • [49] Zones of representation for PM10 measurements along the US/Mexico border
    Chow, JC
    Watson, JG
    SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 276 (1-3) : 49 - 68
  • [50] Field evaluation of an electrostatic PM10 mass monitor used for continuous ambient particulate air pollution measurements
    Yawootti, Artit
    Intra, Panich
    Tippayawong, Nakorn
    Sampattagul, Sate
    JOURNAL OF ELECTROSTATICS, 2015, 78 : 46 - 54