Use of four-electrode arrays in three-dimensional electrical resistivity imaging survey

被引:0
|
作者
Ahmad Neyamadpour
W. A. T. Wan Abdullah
Samsudin Taib
机构
[1] University of Malaya,Department of Physics
[2] University of Malaya,Department of Geology
来源
关键词
electrical resistivity imaging; four-electrode arrays; robust inversion technique; apparent resistivity;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this paper is to investigate the applicability of four-electrode arrays in 3D electrical resistivity imaging survey. A 3D resistivity imaging survey was carried out along fourteen parallel lines using dipole-dipole, Wenner-Schlumberger, and Wenner arrays with 2 m minimum electrode spacings. Roll-along measurements using a line spacing of 1 m were carried out covering a grid of 20 × 14 electrodes. The 3D least squares algorithm, based on the robust inversion method, was used in the inversion of the 3D apparent resistivity data sets. The results show that the 3D electrical resistivity imaging survey using the Wenner-Schlumberger and the dipole-dipole arrays, or the Wenner and the dipole-dipole arrays, in combination with an appropriate 3D inversion method, can be highly useful when the site conditions do not allow using the pole-pole or pole-dipole arrays.
引用
收藏
页码:299 / 311
页数:12
相关论文
共 50 条
  • [31] Micromachined three-dimensional electrode arrays for transcutaneous nerve tracking
    Rajaraman, Swaminathan
    Bragg, Julian A.
    Ross, James D.
    Allen, Mark G.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (08)
  • [32] The use of three-dimensional imaging in orthodontics
    Moss, J. P.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2006, 28 (05) : 416 - 425
  • [33] Local electrical stimulation of single myocytes using three-dimensional electrode arrays with small interelectrode distances
    Braeken, D.
    Huys, R.
    Jans, D.
    Loo, Josine
    Rand, D. R.
    Borghs, G.
    Callewaert, G.
    Bartic, C.
    MICRO-AND NANOSYSTEMS IN MEDICINE, ACTIVE IMPLANTS, BIOSENSORS, 2009, 25 (08): : 212 - +
  • [34] DC four-electrode method for electrical resistance measurement of conductive composites
    Han, Bao-Zhong
    Han, Bao-Guo
    Wang, Yan-Jie
    Jiang, Hui
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (10): : 1677 - 1680
  • [35] Three-dimensional imaging of subsurface structures using resistivity data
    Yi, MJ
    Kim, JH
    Song, Y
    Cho, SJ
    Chung, SH
    Suh, JH
    GEOPHYSICAL PROSPECTING, 2001, 49 (04) : 483 - 497
  • [36] Sensor Design for Four-Electrode Electrical Resistance Tomography With Voltage Excitation
    Rodriguez-Frias, Marco Antonio
    Yang, Wuqiang
    IEEE SENSORS JOURNAL, 2019, 19 (12) : 4612 - 4622
  • [37] Three-Dimensional Electromagnetic and Electrical Simulation of HgCdTe Pixel Arrays
    Keasler, Craig A.
    Bellotti, Enrico
    JOURNAL OF ELECTRONIC MATERIALS, 2011, 40 (08) : 1795 - 1801
  • [38] Three-Dimensional Electromagnetic and Electrical Simulation of HgCdTe Pixel Arrays
    Craig A. Keasler
    Enrico Bellotti
    Journal of Electronic Materials, 2011, 40 : 1795 - 1801
  • [39] Investigation into the effects of haematocrit and temperature on the resistivity of mammalian blood using a four-electrode probe
    S. C. Tjin
    T. Xie
    Y. Z. Lam
    Medical and Biological Engineering and Computing, 1998, 36 : 467 - 470
  • [40] Two-dimensional and three-dimensional resistivity imaging in archaeological site investigation
    Papadopoulos, N. G.
    Tsourlos, P.
    Tsokas, G. N.
    Sarris, A.
    ARCHAEOLOGICAL PROSPECTION, 2006, 13 (03) : 163 - 181