Use of four-electrode arrays in three-dimensional electrical resistivity imaging survey

被引:0
|
作者
Ahmad Neyamadpour
W. A. T. Wan Abdullah
Samsudin Taib
机构
[1] University of Malaya,Department of Physics
[2] University of Malaya,Department of Geology
来源
关键词
electrical resistivity imaging; four-electrode arrays; robust inversion technique; apparent resistivity;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this paper is to investigate the applicability of four-electrode arrays in 3D electrical resistivity imaging survey. A 3D resistivity imaging survey was carried out along fourteen parallel lines using dipole-dipole, Wenner-Schlumberger, and Wenner arrays with 2 m minimum electrode spacings. Roll-along measurements using a line spacing of 1 m were carried out covering a grid of 20 × 14 electrodes. The 3D least squares algorithm, based on the robust inversion method, was used in the inversion of the 3D apparent resistivity data sets. The results show that the 3D electrical resistivity imaging survey using the Wenner-Schlumberger and the dipole-dipole arrays, or the Wenner and the dipole-dipole arrays, in combination with an appropriate 3D inversion method, can be highly useful when the site conditions do not allow using the pole-pole or pole-dipole arrays.
引用
收藏
页码:299 / 311
页数:12
相关论文
共 50 条
  • [21] Embedded-based Instrumentation System for Electrical Resistivity Measurement on Conductive Concrete using Four-Electrode Method
    Toresano, La Ode Husein Z.
    Prawito
    Sudarmaji, Arief
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS, 2015, : 72 - 79
  • [22] A three-dimensional image reconstruction algorithm for electrical impedance tomography using planar electrode arrays
    Perez, Husein
    Pidcock, Michael
    Sebu, Cristiana
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2017, 25 (04) : 471 - 491
  • [23] Electrical Contacts to Three-Dimensional Arrays of Carbon Nanotubes
    Cummings, Aron W.
    Varennes, Julien
    Leonard, Francois
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2013, 12 (06) : 1166 - 1172
  • [24] Three-Dimensional Electrical Resistivity Tomography for Leachate Imaging Considering Thin Impermeable Layers of Landfills
    Li, Yongji
    Liu, Yunhe
    Yin, Changchun
    Su, Yang
    Ke, Zhiyuan
    Wang, Luyuan
    Ren, Xiuyan
    Zhang, Bo
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2024, 62
  • [25] An application of three-dimensional electrical resistivity imaging for the detection of an underground waste-water system
    Neyamadpour, Ahmad
    Taib, Samsudin
    Abdullah, W. A. T. Wan
    STUDIA GEOPHYSICA ET GEODAETICA, 2009, 53 (03) : 389 - 402
  • [26] An application of three-dimensional electrical resistivity imaging for the detection of an underground waste-water system
    Ahmad Neyamadpour
    Samsudin Taib
    W. A. T. Wan Abdullah
    Studia Geophysica et Geodaetica, 2009, 53 : 389 - 402
  • [27] Geometric effects on resistivity measurements with four-electrode probes in isotropic and anisotropic tissues
    Wang, YQ
    Schimpf, PH
    Haynor, DR
    Kim, Y
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (07) : 877 - 884
  • [28] Application of Two Dimensional Electrical Resistivity Tomography (ERT) For Moisture Detection in Thessaloniki's Rotunda Pillars and Three-Dimensional ERT Modeling Using Optimized Electrode Arrays
    Louvaris, Prodromos
    Tsourlos, Panagiotis
    Tsokas, Gregory
    Vargemezis, George
    Diamanti, Nectaria
    Polydoropoulos, Konstantinos
    Zacharopoulou, Georgia
    ARCHEOSCIENCES-REVUE D ARCHEOMETRIE, 2021, 45 (01) : 179 - 181
  • [29] Adaptation of three-electrode arrhythmia simulators to four-electrode defibrillator monitors
    Jimenez, Daniel
    del Castillo, Jimena
    Lopez-Herce, Jesus
    RESUSCITATION PLUS, 2025, 22
  • [30] Three-dimensional electrical capacitance tomography imaging
    Soleimani, M.
    INSIGHT, 2006, 48 (10) : 613 - 617