Liquid flooded flow-focusing microfluidic device for in situ generation of monodisperse microbubbles

被引:0
|
作者
Ali H. Dhanaliwala
Johnny L. Chen
Shiying Wang
John A. Hossack
机构
[1] University of Virginia,Department of Biomedical Engineering
来源
关键词
Microfluidics; Flow-focusing; Monodisperse microbubbles; Flooded input; In situ production;
D O I
暂无
中图分类号
学科分类号
摘要
Current microbubble-based ultrasound contrast agents are administered intravenously resulting in large losses of contrast agent, systemic distribution, and strict requirements for microbubble longevity and diameter size. Instead we propose in situ production of microbubbles directly within the vasculature to avoid these limitations. Flow-focusing microfluidic devices (FFMDs) are a promising technology for enabling in situ production as they can produce microbubbles with precisely controlled diameters in real-time. While the microfluidic chips are small, the addition of inlets and interconnects to supply the gas and liquid phase greatly increases the footprint of these devices preventing the miniaturization of FFMDs to sizes compatible with medium and small vessels. To overcome this challenge, we introduce a new method for supplying the liquid (shell) phase to a FFMD that eliminates bulky interconnects. A pressurized liquid-filled chamber is coupled to the liquid inlets of an FFMD, which we term a flooded FFMD. The microbubble diameter and production rate of flooded FFMDs were measured optically over a range of gas pressures and liquid flow rates. The smallest FFMD manufactured measured 14.5 × 2.8 × 2.3 mm. A minimum microbubble diameter of 8.1 ± 0.3 μm was achieved at a production rate of 450,000 microbubbles/s (MB/s). This represents a significant improvement with respect to any previously reported result. The flooded design also simplifies parallelization and production rates of up to 670,000 MB/s were achieved using a parallelized version of the flooded FFMD. In addition, an intravascular ultrasound (IVUS) catheter was coupled to the flooded FFMD to produce an integrated ultrasound contrast imaging device. B-mode and IVUS images of microbubbles produced from a flooded FFMD in a gelatin phantom vessel were acquired to demonstrate the potential of in situ microbubble production and real-time imaging. Microbubble production rates of 222,000 MB/s from a flooded FFMD within the vessel lumen provided a 23 dB increase in B-mode contrast. Overall, the flooded design is a critical contribution towards the long-term goal of utilizing in situ produced microbubbles for contrast enhanced ultrasound imaging of, and drug delivery to, the vasculature.
引用
收藏
页码:457 / 467
页数:10
相关论文
共 50 条
  • [41] Stability of Monodisperse Phospholipid-Coated Microbubbles Formed by Flow-Focusing at High Production Rates
    Segers, Tim
    de Rond, Leonie
    de Jong, Nico
    Borden, Mark
    Versluis, Michel
    LANGMUIR, 2016, 32 (16) : 3937 - 3944
  • [42] Liquid-in-gas droplet microfluidics; experimental characterization of droplet morphology, generation frequency, and monodispersity in a flow-focusing microfluidic device
    Tirandazi, Pooyan
    Hidrovo, Carlos H.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2017, 27 (07)
  • [43] Emulsification in a microfluidic flow-focusing device: Effect of the dispersed phase viscosity
    Liu, Zheyu
    Chai, Maojie
    Chen, Xin
    Hejazi, Seyed Hossein
    Li, Yiqiang
    FUEL, 2021, 283
  • [44] The effect of interfacial tension on droplet formation in flow-focusing microfluidic device
    Lu Peng
    Min Yang
    Shi-shang Guo
    Wei Liu
    Xing-zhong Zhao
    Biomedical Microdevices, 2011, 13 : 559 - 564
  • [45] Continuous Production of the Nanoscale Liposome in a Double Flow-Focusing Microfluidic Device
    Aghaei, Halimeh
    Nazare, Ali Reza Solaimany
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (51) : 23032 - 23045
  • [46] The effect of interfacial tension on droplet formation in flow-focusing microfluidic device
    Peng, Lu
    Yang, Min
    Guo, Shi-shang
    Liu, Wei
    Zhao, Xing-zhong
    BIOMEDICAL MICRODEVICES, 2011, 13 (03) : 559 - 564
  • [47] Efficient thermal lens nanoparticle detection in a flow-focusing microfluidic device
    Yamaoka, Satomi
    Kataoka, Yui
    Kazama, Yuto
    Fujii, Yusaku
    Hibara, Akihide
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 : 581 - 586
  • [48] Droplet formation via squeezing mechanism in a microfluidic flow-focusing device
    Gupta, Amit
    Matharoo, Harpreet S.
    Makkar, Devavret
    Kumar, Ranganathan
    COMPUTERS & FLUIDS, 2014, 100 : 218 - 226
  • [49] Numerical studies of double emulsions in a coaxial flow-focusing microfluidic device
    Zhao, Zhenyu
    Dong, Bo
    Chen, Cong
    Li, Weizhong
    PROCEEDINGS OF THE ASME POWER CONFERENCE JOINT WITH ICOPE-17, 2017, VOL 2, 2017,
  • [50] Numerical Insights on Controlled Droplet Formation in a Microfluidic Flow-Focusing Device
    Sontti, Somasekhara Goud
    Atta, Arnab
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (09) : 3702 - 3716