Liquid flooded flow-focusing microfluidic device for in situ generation of monodisperse microbubbles

被引:0
|
作者
Ali H. Dhanaliwala
Johnny L. Chen
Shiying Wang
John A. Hossack
机构
[1] University of Virginia,Department of Biomedical Engineering
来源
关键词
Microfluidics; Flow-focusing; Monodisperse microbubbles; Flooded input; In situ production;
D O I
暂无
中图分类号
学科分类号
摘要
Current microbubble-based ultrasound contrast agents are administered intravenously resulting in large losses of contrast agent, systemic distribution, and strict requirements for microbubble longevity and diameter size. Instead we propose in situ production of microbubbles directly within the vasculature to avoid these limitations. Flow-focusing microfluidic devices (FFMDs) are a promising technology for enabling in situ production as they can produce microbubbles with precisely controlled diameters in real-time. While the microfluidic chips are small, the addition of inlets and interconnects to supply the gas and liquid phase greatly increases the footprint of these devices preventing the miniaturization of FFMDs to sizes compatible with medium and small vessels. To overcome this challenge, we introduce a new method for supplying the liquid (shell) phase to a FFMD that eliminates bulky interconnects. A pressurized liquid-filled chamber is coupled to the liquid inlets of an FFMD, which we term a flooded FFMD. The microbubble diameter and production rate of flooded FFMDs were measured optically over a range of gas pressures and liquid flow rates. The smallest FFMD manufactured measured 14.5 × 2.8 × 2.3 mm. A minimum microbubble diameter of 8.1 ± 0.3 μm was achieved at a production rate of 450,000 microbubbles/s (MB/s). This represents a significant improvement with respect to any previously reported result. The flooded design also simplifies parallelization and production rates of up to 670,000 MB/s were achieved using a parallelized version of the flooded FFMD. In addition, an intravascular ultrasound (IVUS) catheter was coupled to the flooded FFMD to produce an integrated ultrasound contrast imaging device. B-mode and IVUS images of microbubbles produced from a flooded FFMD in a gelatin phantom vessel were acquired to demonstrate the potential of in situ microbubble production and real-time imaging. Microbubble production rates of 222,000 MB/s from a flooded FFMD within the vessel lumen provided a 23 dB increase in B-mode contrast. Overall, the flooded design is a critical contribution towards the long-term goal of utilizing in situ produced microbubbles for contrast enhanced ultrasound imaging of, and drug delivery to, the vasculature.
引用
收藏
页码:457 / 467
页数:10
相关论文
共 50 条
  • [21] Study on Flow-Focusing Microfluidic Device with External Electric Field for Droplet Generation
    Cuong Nguyen Nhu
    Hang Nguyen Thu
    Luan Le Van
    Trinh Chu Duc
    Van Thanh Dau
    Tung Thanh Bui
    ADVANCES IN ENGINEERING RESEARCH AND APPLICATION, 2019, 63 : 553 - 559
  • [22] SYNTHESIS AND CHARACTERIZATION OF TRANSIENTLY STABLE ALBUMIN-COATED MICROBUBBLES VIA A FLOW-FOCUSING MICROFLUIDIC DEVICE
    Chen, Johnny L.
    Dhanaliwala, Ali H.
    Dixon, Adam J.
    Klibanov, Alexander L.
    Hossack, John A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (02): : 400 - 409
  • [23] A hybrid axisymmetric flow-focusing device for monodisperse picoliter droplets
    Morimoto, Yuya
    Kuribayashi-Shigetomi, Kaori
    Takeuchi, Shoji
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (05)
  • [24] Micropipette-Based Microfluidic Device for Monodisperse Microbubbles Generation
    Matsumi, Carlos Toshiyuki
    da Silva, Wilson Jose
    Schneider, Fabio Kurt
    Maia, Joaquim Miguel
    Morales, Rigoberto E. M.
    Araujo Filho, Walter Duarte
    MICROMACHINES, 2018, 9 (08):
  • [25] Towards Monodisperse Microbubble Populations via Microfluidic Chip Flow-Focusing
    Cui, Yaoyao
    Campbell, Paul A.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1663 - 1666
  • [26] Preparation of Monodisperse Biodegradable Polymer Microparticles Using a Microfluidic Flow-Focusing Device for Controlled Drug Delivery
    Xu, Qiaobing
    Hashimoto, Michinao
    Dang, Tram T.
    Hoare, Todd
    Kohane, Daniel S.
    Whitesides, George M.
    Langer, Robert
    Anderson, Daniel G.
    SMALL, 2009, 5 (13) : 1575 - 1581
  • [27] SIMPLE FLOW-FOCUSING MICROFLUIDIC CHIP FOR DROPLET GENERATION
    Krivankova, Jana
    Basova, Evgenia
    Foret, Frantisek
    CECE 2015: 12TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2015, : 127 - 129
  • [28] Negative Pressure Provides Simple and Stable Droplet Generation in a Flow-Focusing Microfluidic Device
    Filatov, Nikita A.
    Evstrapov, Anatoly A.
    Bukatin, Anton S.
    MICROMACHINES, 2021, 12 (06)
  • [29] Formation of monodisperse microbubbles in a microfluidic device
    Xu, J. H.
    Li, S. W.
    Chen, G. G.
    Luo, G. S.
    AICHE JOURNAL, 2006, 52 (06) : 2254 - 2259
  • [30] Monodisperse droplets by impinging flow-focusing
    Wu, Tao
    Luo, Zhaofeng
    Ding, Weiping
    Cheng, Zhengdong
    He, Liqun
    MICROFLUIDICS AND NANOFLUIDICS, 2017, 21 (08)